219 related articles for article (PubMed ID: 31209607)
21. Endoscopic Ultrasound-Guided Fine Needle Biopsy Using 22-Gauge Franseen Needle for the Histological Diagnosis of Solid Lesions: A Multicenter Prospective Pilot Study.
Mita N; Iwashita T; Uemura S; Iwasa Y; Toda K; Mukai T; Miyazaki T; Yasuda I; Shimizu M
Dig Dis Sci; 2020 Apr; 65(4):1155-1163. PubMed ID: 31531819
[TBL] [Abstract][Full Text] [Related]
22. Multicenter, randomized comparison of the diagnostic accuracy of 19-gauge stainless steel and nitinol-based needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses.
Hann A; Epp S; Veits L; Rosien U; Siegel J; Möschler O; Bohle W; Meining A
United European Gastroenterol J; 2020 Apr; 8(3):314-320. PubMed ID: 32213013
[TBL] [Abstract][Full Text] [Related]
23. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.
Lee BS; Cho CM; Jung MK; Jang JS; Bae HI
Gut Liver; 2017 Jul; 11(4):559-566. PubMed ID: 28208006
[TBL] [Abstract][Full Text] [Related]
24. Comparison of fine-needle aspiration and fine-needle biopsy devices for endoscopic ultrasound-guided sampling of solid lesions: a systemic review and meta-analysis.
van Riet PA; Erler NS; Bruno MJ; Cahen DL
Endoscopy; 2021 Apr; 53(4):411-423. PubMed ID: 32583392
[TBL] [Abstract][Full Text] [Related]
25. Endoscopic ultrasound-guided fine-needle biopsy of small solid pancreatic lesions using a 22-gauge needle with side fenestration.
Fabbri C; Luigiano C; Maimone A; Tarantino I; Baccarini P; Fornelli A; Liotta R; Polifemo A; Barresi L; Traina M; Virgilio C; Cennamo V
Surg Endosc; 2015 Jun; 29(6):1586-90. PubMed ID: 25303907
[TBL] [Abstract][Full Text] [Related]
26. EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study.
Kandel P; Tranesh G; Nassar A; Bingham R; Raimondo M; Woodward TA; Gomez V; Wallace MB
Gastrointest Endosc; 2016 Dec; 84(6):1034-1039. PubMed ID: 27018087
[TBL] [Abstract][Full Text] [Related]
27. Evaluation of 22G fine-needle aspiration (FNA) versus fine-needle biopsy (FNB) for endoscopic ultrasound-guided sampling of pancreatic lesions: a prospective comparison study.
Tian L; Tang AL; Zhang L; Liu XW; Li JB; Wang F; Shen SR; Wang XY
Surg Endosc; 2018 Aug; 32(8):3533-3539. PubMed ID: 29404729
[TBL] [Abstract][Full Text] [Related]
28. Histologic retrieval rate of a newly designed side-bevelled 20G needle for EUS-guided tissue acquisition of solid pancreatic lesions.
Armellini E; Manfrin E; Trisolini E; Andorno S; Ballarè M; Bernardoni L; Boldorini RL; Gabbrielli A; Frulloni L; Larghi A; Occhipinti P; Scarpa A; Crinò SF
United European Gastroenterol J; 2019 Feb; 7(1):96-104. PubMed ID: 30788121
[TBL] [Abstract][Full Text] [Related]
29. Endoscopic Ultrasound-guided Fine-needle Biopsy With or Without Rapid On-site Evaluation for Diagnosis of Solid Pancreatic Lesions: A Randomized Controlled Non-Inferiority Trial.
Crinò SF; Di Mitri R; Nguyen NQ; Tarantino I; de Nucci G; Deprez PH; Carrara S; Kitano M; Shami VM; Fernández-Esparrach G; Poley JW; Baldaque-Silva F; Itoi T; Manfrin E; Bernardoni L; Gabbrielli A; Conte E; Unti E; Naidu J; Ruszkiewicz A; Amata M; Liotta R; Manes G; Di Nuovo F; Borbath I; Komuta M; Lamonaca L; Rahal D; Hatamaru K; Itonaga M; Rizzatti G; Costamagna G; Inzani F; Curatolo M; Strand DS; Wang AY; Ginès À; Sendino O; Signoretti M; van Driel LMJW; Dolapcsiev K; Matsunami Y; van der Merwe S; van Malenstein H; Locatelli F; Correale L; Scarpa A; Larghi A
Gastroenterology; 2021 Sep; 161(3):899-909.e5. PubMed ID: 34116031
[TBL] [Abstract][Full Text] [Related]
30. Impact of EUS-guided fine-needle biopsy sampling with a new core needle on the need for onsite cytopathologic assessment: a preliminary study.
Rodrigues-Pinto E; Jalaj S; Grimm IS; Baron TH
Gastrointest Endosc; 2016 Dec; 84(6):1040-1046. PubMed ID: 27345131
[TBL] [Abstract][Full Text] [Related]
31. Comparison of the Diagnostic Yield of the Standard 22-Gauge Needle and the New 20-Gauge Forward-Bevel Core Biopsy Needle for Endoscopic Ultrasound-Guided Tissue Acquisition from Pancreatic Lesions.
Fujie S; Ishiwatari H; Sasaki K; Sato J; Matsubayashi H; Yoshida M; Ito S; Kawata N; Imai K; Kakushima N; Takizawa K; Hotta K; Ono H
Gut Liver; 2019 May; 13(3):349-355. PubMed ID: 30600677
[TBL] [Abstract][Full Text] [Related]
32. Touch imprint cytology on endoscopic ultrasound fine-needle biopsy provides comparable sample quality and diagnostic yield to standard endoscopic ultrasound fine-needle aspiration specimens in the evaluation of solid pancreatic lesions.
Crinò SF; Larghi A; Bernardoni L; Parisi A; Frulloni L; Gabbrielli A; Parcesepe P; Scarpa A; Manfrin E
Cytopathology; 2019 Mar; 30(2):179-186. PubMed ID: 30484917
[TBL] [Abstract][Full Text] [Related]
33. Analysis of Fine-Needle Biopsy vs Fine-Needle Aspiration in Diagnosis of Pancreatic and Abdominal Masses: A Prospective, Multicenter, Randomized Controlled Trial.
Cheng B; Zhang Y; Chen Q; Sun B; Deng Z; Shan H; Dou L; Wang J; Li Y; Yang X; Jiang T; Xu G; Wang G
Clin Gastroenterol Hepatol; 2018 Aug; 16(8):1314-1321. PubMed ID: 28733257
[TBL] [Abstract][Full Text] [Related]
34. A prospective multicenter study of endoscopic ultrasound-guided fine needle biopsy using a 22-gauge Franseen needle for pancreatic solid lesions.
Ishigaki K; Nakai Y; Sasahira N; Sugimori K; Kitamura K; Iwai T; Matsubara S; Shimura K; Itoi T; Ryozawa S; Ushio J; Doi S; Imazu H; Maetani I; Isayama H;
J Gastroenterol Hepatol; 2021 Oct; 36(10):2754-2761. PubMed ID: 33939863
[TBL] [Abstract][Full Text] [Related]
35. Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses.
Sakamoto H; Kitano M; Komaki T; Noda K; Chikugo T; Dote K; Takeyama Y; Das K; Yamao K; Kudo M
J Gastroenterol Hepatol; 2009 Mar; 24(3):384-90. PubMed ID: 19032453
[TBL] [Abstract][Full Text] [Related]
36. Evaluation of endoscopic ultrasound-guided fine-needle biopsy for preoperative pancreatic solid lesions.
Fujita A; Ryozawa S; Tanisaka Y; Ogawa T; Suzuki M; Katsuda H; Tashima T; Araki R; Mizuide M
Scand J Gastroenterol; 2021 Feb; 56(2):188-192. PubMed ID: 33295211
[TBL] [Abstract][Full Text] [Related]
37. Histologic diagnosis of pancreatic masses using 25-gauge endoscopic ultrasound needles with and without a core trap: a multicenter randomized trial.
Kamata K; Kitano M; Yasukawa S; Kudo M; Chiba Y; Ogura T; Higuchi K; Fukutake N; Ashida R; Yamasaki T; Nebiki H; Hirose S; Hoki N; Asada M; Yazumi S; Takaoka M; Okazaki K; Matsuda F; Okabe Y; Yanagisawa A
Endoscopy; 2016 Jul; 48(7):632-8. PubMed ID: 27129137
[TBL] [Abstract][Full Text] [Related]
38. Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience.
Yusuf TE; Ho S; Pavey DA; Michael H; Gress FG
Endoscopy; 2009 May; 41(5):445-8. PubMed ID: 19418399
[TBL] [Abstract][Full Text] [Related]
39. 22-gauge core
Sterlacci W; Sioulas AD; Veits L; Gönüllü P; Schachschal G; Groth S; Anders M; Kontos CK; Topalidis T; Hinsch A; Vieth M; Rösch T; Denzer UW
World J Gastroenterol; 2016 Oct; 22(39):8820-8830. PubMed ID: 27818598
[TBL] [Abstract][Full Text] [Related]
40. Endoscopic ultrasound-fine needle biopsies of pancreatic lesions: Prospective study of histology quality using Franseen needle.
Stathopoulos P; Pehl A; Breitling LP; Bauer C; Grote T; Gress TM; Denkert C; Denzer UW
World J Gastroenterol; 2020 Oct; 26(37):5693-5704. PubMed ID: 33088162
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]