These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 31216314)

  • 1. A novel diversity method for smartphone camera-based heart rhythm signals in the presence of motion and noise artifacts.
    Tabei F; Zaman R; Foysal KH; Kumar R; Kim Y; Chong JW
    PLoS One; 2019; 14(6):e0218248. PubMed ID: 31216314
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time-Frequency Spectral Features.
    Dao D; Salehizadeh SMA; Noh Y; Chong JW; Cho CH; McManus D; Darling CE; Mendelson Y; Chon KH
    IEEE J Biomed Health Inform; 2017 Sep; 21(5):1242-1253. PubMed ID: 28113791
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Photoplethysmograph signal reconstruction based on a novel hybrid motion artifact detection-reduction approach. Part I: Motion and noise artifact detection.
    Chong JW; Dao DK; Salehizadeh SM; McManus DD; Darling CE; Chon KH; Mendelson Y
    Ann Biomed Eng; 2014 Nov; 42(11):2238-50. PubMed ID: 25092422
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Motion and Noise Artifact-Resilient Atrial Fibrillation Detection using a Smartphone.
    Chong JW; Cho CH; Tabei F; Le-Anh D; Esa N; McManus DD; Chon KH
    IEEE J Emerg Sel Top Circuits Syst; 2018 Jun; 8(2):230-239. PubMed ID: 30687580
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel method based on two cameras for accurate estimation of arterial oxygen saturation.
    Liu H; Ivanov K; Wang Y; Wang L
    Biomed Eng Online; 2015 May; 14():52. PubMed ID: 26025439
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Novel Personalized Motion and Noise Artifact (MNA) Detection Method for Smartphone Photoplethysmograph (PPG) Signals.
    Tabei F; Kumar R; Phan TN; McManus DD; Chong JW
    IEEE Access; 2018; 6():60498-60512. PubMed ID: 31263653
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Novel Framework for Motion-Tolerant Instantaneous Heart Rate Estimation by Phase-Domain Multiview Dynamic Time Warping.
    Zhang Q; Zhou D; Zeng X
    IEEE Trans Biomed Eng; 2017 Nov; 64(11):2562-2574. PubMed ID: 28113198
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Smartphone-based photoplethysmographic imaging for heart rate monitoring.
    Alafeef M
    J Med Eng Technol; 2017 Jul; 41(5):387-395. PubMed ID: 28300460
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI.
    Spicher N; Kukuk M; Maderwald S; Ladd ME
    Biomed Eng Online; 2016 Nov; 15(1):126. PubMed ID: 27881126
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Signal quality measures for pulse oximetry through waveform morphology analysis.
    Sukor JA; Redmond SJ; Lovell NH
    Physiol Meas; 2011 Mar; 32(3):369-84. PubMed ID: 21330696
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Photoplethysmograph signal reconstruction based on a novel motion artifact detection-reduction approach. Part II: Motion and noise artifact removal.
    Salehizadeh SM; Dao DK; Chong JW; McManus D; Darling C; Mendelson Y; Chon KH
    Ann Biomed Eng; 2014 Nov; 42(11):2251-63. PubMed ID: 24823655
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimizing Estimates of Instantaneous Heart Rate from Pulse Wave Signals with the Synchrosqueezing Transform.
    Wu HT; Lewis GF; Davila MI; Daubechies I; Porges SW
    Methods Inf Med; 2016 Oct; 55(5):463-472. PubMed ID: 27626806
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Resting and Postexercise Heart Rate Detection From Fingertip and Facial Photoplethysmography Using a Smartphone Camera: A Validation Study.
    Yan BP; Chan CK; Li CK; To OT; Lai WH; Tse G; Poh YC; Poh MZ
    JMIR Mhealth Uhealth; 2017 Mar; 5(3):e33. PubMed ID: 28288955
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor.
    Salehizadeh SM; Dao D; Bolkhovsky J; Cho C; Mendelson Y; Chon KH
    Sensors (Basel); 2015 Dec; 16(1):. PubMed ID: 26703618
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Artifact reduction based on Empirical Mode Decomposition (EMD) in photoplethysmography for pulse rate detection.
    Wang Q; Yang P; Zhang Y
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():959-62. PubMed ID: 21096980
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vivo investigation of ear canal pulse oximetry during hypothermia.
    Budidha K; Kyriacou PA
    J Clin Monit Comput; 2018 Feb; 32(1):97-107. PubMed ID: 28130679
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reference signal less Fourier analysis based motion artifact removal algorithm for wearable photoplethysmography devices to estimate heart rate during physical exercises.
    Pankaj ; Kumar A; Komaragiri R; Kumar M
    Comput Biol Med; 2022 Feb; 141():105081. PubMed ID: 34952340
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Smartwatch Based Atrial Fibrillation Detection from Photoplethysmography Signals.
    Bashar SK; Han D; Ding E; Whitcomb C; McManus DD; Chon KH
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():4306-4309. PubMed ID: 31946820
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Research on adaptive pulse signal extraction algorithm based on fingertip video image].
    Yu J; Zhou L; Liu Z; Li Z; Shan Q
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2020 Feb; 37(1):150-157. PubMed ID: 32096389
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Contact-Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals.
    Yan BP; Lai WHS; Chan CKY; Chan SC; Chan LH; Lam KM; Lau HW; Ng CM; Tai LY; Yip KW; To OTL; Freedman B; Poh YC; Poh MZ
    J Am Heart Assoc; 2018 Apr; 7(8):. PubMed ID: 29622592
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.