211 related articles for article (PubMed ID: 31225973)
1. Regional Ventilation Displayed by Electrical Impedance Tomography as an Incentive to Decrease Positive End-Expiratory Pressure.
Yoshida T; Piraino T; Lima CAS; Kavanagh BP; Amato MBP; Brochard L
Am J Respir Crit Care Med; 2019 Oct; 200(7):933-937. PubMed ID: 31225973
[No Abstract] [Full Text] [Related]
2. Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography.
Mauri T; Eronia N; Turrini C; Battistini M; Grasselli G; Rona R; Volta CA; Bellani G; Pesenti A
Intensive Care Med; 2016 Oct; 42(10):1576-1587. PubMed ID: 27518321
[TBL] [Abstract][Full Text] [Related]
3. Assessment of regional ventilation in acute respiratory distress syndrome by electrical impedance tomography.
Stankiewicz-Rudnicki M; Gaszyński T; Gaszyński W
Anaesthesiol Intensive Ther; 2015; 47(1):77-81. PubMed ID: 25751294
[TBL] [Abstract][Full Text] [Related]
4. Electrical impedance tomography monitoring in acute respiratory distress syndrome patients with mechanical ventilation during prolonged positive end-expiratory pressure adjustments.
Hsu CF; Cheng JS; Lin WC; Ko YF; Cheng KS; Lin SH; Chen CW
J Formos Med Assoc; 2016 Mar; 115(3):195-202. PubMed ID: 25843526
[TBL] [Abstract][Full Text] [Related]
5. Bedside Contribution of Electrical Impedance Tomography to Setting Positive End-Expiratory Pressure for Extracorporeal Membrane Oxygenation-treated Patients with Severe Acute Respiratory Distress Syndrome.
Franchineau G; Bréchot N; Lebreton G; Hekimian G; Nieszkowska A; Trouillet JL; Leprince P; Chastre J; Luyt CE; Combes A; Schmidt M
Am J Respir Crit Care Med; 2017 Aug; 196(4):447-457. PubMed ID: 28103448
[TBL] [Abstract][Full Text] [Related]
6. Mapping Regional Differences of Local Pressure-Volume Curves With Electrical Impedance Tomography.
Beda A; Carvalho AR; Carvalho NC; Hammermüller S; Amato MB; Muders T; Gittel C; Noreikat K; Wrigge H; Reske AW
Crit Care Med; 2017 Apr; 45(4):679-686. PubMed ID: 28079607
[TBL] [Abstract][Full Text] [Related]
7. Detection of optimal PEEP for equal distribution of tidal volume by volumetric capnography and electrical impedance tomography during decreasing levels of PEEP in post cardiac-surgery patients.
Blankman P; Shono A; Hermans BJ; Wesselius T; Hasan D; Gommers D
Br J Anaesth; 2016 Jun; 116(6):862-9. PubMed ID: 27199318
[TBL] [Abstract][Full Text] [Related]
8. Mechanical ventilation in acute respiratory distress syndrome: The open lung revisited.
Amado-Rodríguez L; Del Busto C; García-Prieto E; Albaiceta GM
Med Intensiva; 2017 Dec; 41(9):550-558. PubMed ID: 28238441
[TBL] [Abstract][Full Text] [Related]
9. [The basics on mechanical ventilation support in acute respiratory distress syndrome].
Tomicic V; Fuentealba A; Martínez E; Graf J; Batista Borges J
Med Intensiva; 2010; 34(6):418-27. PubMed ID: 20097448
[TBL] [Abstract][Full Text] [Related]
10. Topographic distribution of tidal ventilation in acute respiratory distress syndrome: effects of positive end-expiratory pressure and pressure support.
Mauri T; Bellani G; Confalonieri A; Tagliabue P; Turella M; Coppadoro A; Citerio G; Patroniti N; Pesenti A
Crit Care Med; 2013 Jul; 41(7):1664-73. PubMed ID: 23507723
[TBL] [Abstract][Full Text] [Related]
11. Physiological Effects of the Open Lung Approach in Patients with Early, Mild, Diffuse Acute Respiratory Distress Syndrome: An Electrical Impedance Tomography Study.
Cinnella G; Grasso S; Raimondo P; D'Antini D; Mirabella L; Rauseo M; Dambrosio M
Anesthesiology; 2015 Nov; 123(5):1113-21. PubMed ID: 26397017
[TBL] [Abstract][Full Text] [Related]
12. Use of thoracic electrical impedance tomography as an auxiliary tool for alveolar recruitment maneuvers in acute respiratory distress syndrome: case report and brief literature review.
Rosa RG; Rutzen W; Madeira L; Ascoli AM; Dexheimer Neto FL; Maccari JG; Oliveira RP; Teixeira C
Rev Bras Ter Intensiva; 2015; 27(4):406-11. PubMed ID: 26761481
[TBL] [Abstract][Full Text] [Related]
13. Electrical impedance tomography-guided prone positioning in a patient with acute cor pulmonale associated with severe acute respiratory distress syndrome.
Kotani T; Tanabe H; Yusa H; Saito S; Yamazaki K; Ozaki M
J Anesth; 2016 Feb; 30(1):161-5. PubMed ID: 26446805
[TBL] [Abstract][Full Text] [Related]
14. Mechanical ventilation guided by electrical impedance tomography in pediatric acute respiratory distress syndrome.
Dmytrowich J; Holt T; Schmid K; Hansen G
J Clin Monit Comput; 2018 Jun; 32(3):503-507. PubMed ID: 28730574
[TBL] [Abstract][Full Text] [Related]
15. Spontaneous Effort During Mechanical Ventilation: Maximal Injury With Less Positive End-Expiratory Pressure.
Yoshida T; Roldan R; Beraldo MA; Torsani V; Gomes S; De Santis RR; Costa EL; Tucci MR; Lima RG; Kavanagh BP; Amato MB
Crit Care Med; 2016 Aug; 44(8):e678-88. PubMed ID: 27002273
[TBL] [Abstract][Full Text] [Related]
16. Higher levels of spontaneous breathing reduce lung injury in experimental moderate acute respiratory distress syndrome.
Carvalho NC; Güldner A; Beda A; Rentzsch I; Uhlig C; Dittrich S; Spieth PM; Wiedemann B; Kasper M; Koch T; Richter T; Rocco PR; Pelosi P; de Abreu MG
Crit Care Med; 2014 Nov; 42(11):e702-15. PubMed ID: 25162475
[TBL] [Abstract][Full Text] [Related]
17. How ARDS should be treated.
Gattinoni L; Quintel M
Crit Care; 2016 Apr; 20():86. PubMed ID: 27048605
[TBL] [Abstract][Full Text] [Related]
18. Optimizing PEEP by Electrical Impedance Tomography in a Porcine Animal Model of ARDS.
Hochhausen N; Biener I; Rossaint R; Follmann A; Bleilevens C; Braunschweig T; Leonhardt S; Czaplik M
Respir Care; 2017 Mar; 62(3):340-349. PubMed ID: 27999152
[TBL] [Abstract][Full Text] [Related]
19. Mechanical ventilation guided by electrical impedance tomography in experimental acute lung injury.
Wolf GK; Gómez-Laberge C; Rettig JS; Vargas SO; Smallwood CD; Prabhu SP; Vitali SH; Zurakowski D; Arnold JH
Crit Care Med; 2013 May; 41(5):1296-304. PubMed ID: 23474677
[TBL] [Abstract][Full Text] [Related]
20. Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography.
Meier T; Luepschen H; Karsten J; Leibecke T; Grossherr M; Gehring H; Leonhardt S
Intensive Care Med; 2008 Mar; 34(3):543-50. PubMed ID: 17653529
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]