These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

303 related articles for article (PubMed ID: 31226456)

  • 21. WEB-only treatment of ruptured and unruptured intracranial aneurysms: a retrospective analysis of 47 aneurysms.
    Ozpeynirci Y; Braun M; Pala A; Schick M; Schmitz B
    Acta Neurochir (Wien); 2019 Aug; 161(8):1507-1513. PubMed ID: 31240584
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Factors that determine aneurysm occlusion after embolization with the Woven EndoBridge (WEB).
    Kabbasch C; Goertz L; Siebert E; Herzberg M; Borggrefe J; Dorn F; Liebig T
    J Neurointerv Surg; 2019 May; 11(5):503-510. PubMed ID: 30355777
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Single-center experience with the Neuroform stent for endovascular treatment of wide-necked intracranial aneurysms.
    Wajnberg E; de Souza JM; Marchiori E; Gasparetto EL
    Surg Neurol; 2009 Dec; 72(6):612-9. PubMed ID: 19604557
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Efficacy and Safety of the Woven EndoBridge (WEB) Device for the Treatment of Intracranial Aneurysms: A Systematic Review and Meta-Analysis.
    Asnafi S; Rouchaud A; Pierot L; Brinjikji W; Murad MH; Kallmes DF
    AJNR Am J Neuroradiol; 2016 Dec; 37(12):2287-2292. PubMed ID: 27516237
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Endovascular treatment of unruptured wide-necked intracranial aneurysms: comparison of dual microcatheter technique and stent-assisted coil embolization.
    Starke RM; Durst CR; Evans A; Ding D; Raper DM; Jensen ME; Crowley RW; Liu KC
    J Neurointerv Surg; 2015 Apr; 7(4):256-61. PubMed ID: 24668256
    [TBL] [Abstract][Full Text] [Related]  

  • 26. SILK flow-diverting device for intracranial aneurysms.
    Binning MJ; Natarajan SK; Bulsara KR; Siddiqui AH; Hopkins LN; Levy EI
    World Neurosurg; 2011 Nov; 76(5):477.e1-6. PubMed ID: 22152578
    [TBL] [Abstract][Full Text] [Related]  

  • 27. WEB embolization versus stent-assisted coiling: comparison of complication rates and angiographic outcomes.
    Kabbasch C; Goertz L; Siebert E; Herzberg M; Borggrefe J; Krischek B; Stavrinou P; Dorn F; Liebig T
    J Neurointerv Surg; 2019 Aug; 11(8):812-816. PubMed ID: 30674636
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Technical aspects of web device in aneurysm treatment.
    Peterson J; Goyal N; Arthur AS; Fiorella D
    J Neurointerv Surg; 2020 Sep; 12(9):924. PubMed ID: 32475818
    [TBL] [Abstract][Full Text] [Related]  

  • 29. T-Configuration Horizontal Low-Profile Visualized Intraluminal Support (LVIS Jr) Device-Assisted Coiling for Treatment of Basilar Tip Aneurysms: A Technical Note.
    Dornbos D; Khandpur U; Youssef PP
    World Neurosurg; 2019 Sep; 129():428-431. PubMed ID: 31158535
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Intrasaccular Flow Disruption with the Woven EndoBridge for Narrow-Necked Aneurysms: A Safety and Feasibility Study.
    Goertz L; Liebig T; Siebert E; Pflaeging M; Forbrig R; Pennig L; Schlamann M; Dorn F; Kabbasch C
    World Neurosurg; 2021 Jul; 151():e278-e285. PubMed ID: 33866026
    [TBL] [Abstract][Full Text] [Related]  

  • 31. How to WEB: a practical review of methodology for the use of the Woven EndoBridge.
    Goyal N; Hoit D; DiNitto J; Elijovich L; Fiorella D; Pierot L; Lamin S; Spelle L; Saatci I; Cekirge S; Arthur AS
    J Neurointerv Surg; 2020 May; 12(5):512-520. PubMed ID: 32005760
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The Woven EndoBridge embolization device for the treatment of intracranial wide-necked bifurcation aneurysms.
    Moore KA; Goyal N; Arthur AS
    Future Cardiol; 2021 Sep; 17(6):953-961. PubMed ID: 33559501
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Woven Endobridge (WEB) Device as a Retreatment Strategy After Unsuccessful Surgical Clipping.
    Booth TC; Parra-Farinas C; deSouza RM; Kandasamy N; Bhattacharya J; Rangi P; Downer J
    World Neurosurg; 2020 Jul; 139():111-120. PubMed ID: 32179191
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Endovascular treatment of cerebral aneurysms using the Woven EndoBridge technique in a single center: preliminary results.
    Lawson A; Goddard T; Ross S; Tyagi A; Deniz K; Patankar T
    J Neurosurg; 2017 Jan; 126(1):17-28. PubMed ID: 27081907
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Coil Embolization Results of the Ruptured Proximal Posteriori Inferior Cerebellar Artery Aneurysm: A Single-Center 10 Years' Experience.
    Kim J; Chang C; Jung YJ
    World Neurosurg; 2018 Sep; 117():e645-e652. PubMed ID: 29945000
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Two-Center Experience in the Endovascular Treatment of Intracranial Aneurysms Using the Woven EndoBridge 17 Device Including Midterm Follow-Up Results: A Retrospective Analysis.
    Maurer C; König I; Berlis A; Weber W; Fischer S
    AJNR Am J Neuroradiol; 2019 Sep; 40(9):1517-1522. PubMed ID: 31467237
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A single centre retrospective analysis of short- and medium-term outcomes using the Woven EndoBridge (WEB) device and identification of the device-to-aneurysm volume ratio as a potential predictor of aneurysm occlusion status.
    Kewlani B; Ryan DJ; Henry J; Wyse G; Fanning N
    Interv Neuroradiol; 2023 Aug; 29(4):393-401. PubMed ID: 35404152
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Persistent Blood Flow inside the Woven EndoBridge Device More Than 6 Months after Intracranial Aneurysm Treatment: Frequency, Mechanisms, and Management-A Retrospective Single-Center Study.
    Nguyen HA; Soize S; Manceau PF; Vudang L; Pierot L
    AJNR Am J Neuroradiol; 2020 Jul; 41(7):1225-1231. PubMed ID: 32527839
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Woven Endobridge (WEB) device for endovascular treatment of complex unruptured aneurysms-a single center experience.
    Lescher S; du Mesnil de Rochemont R; Berkefeld J
    Neuroradiology; 2016 Apr; 58(4):383-90. PubMed ID: 26767527
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Single-center experience in the endovascular treatment of wide-necked intracranial aneurysms with a bridging intra-/extra-aneurysm implant (pCONus).
    Fischer S; Weber A; Titschert A; Brenke C; Kowoll A; Weber W
    J Neurointerv Surg; 2016 Nov; 8(11):1186-1191. PubMed ID: 26658279
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.