These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 31227900)

  • 1. Novel clip applicator for minimally invasive surgery.
    Erridge S; Payne CJ; Sodergren M
    Surg Endosc; 2019 Aug; 33(8):2710-2718. PubMed ID: 31227900
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bursting strength with various methods of renal artery ligation and potential mechanisms of failure.
    Elliott SP; Joel AB; Meng MV; Stoller ML
    J Endourol; 2005 Apr; 19(3):307-11. PubMed ID: 15865519
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Technical characteristics can make the difference in a surgical linear stapler. Or not?
    Giaccaglia V; Antonelli MS; Addario Chieco P; Cocorullo G; Cavallini M; Gulotta G
    J Surg Res; 2015 Jul; 197(1):101-6. PubMed ID: 25918006
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel single-stapling technique for colorectal anastomosis: a pre-ligation single-stapling technique (L-SST) in a porcine model.
    Takeyama H; Yamamoto H; Hata T; Takahashi Y; Ohtsuka M; Nonaka R; Inoue A; Naito A; Matsumura T; Uemura M; Nishimura J; Takemasa I; Mizushima T; Doki Y; Mori M
    Surg Endosc; 2015 Aug; 29(8):2371-6. PubMed ID: 25480605
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Increased burst pressure in gastrointestinal staple-lines using reinforcement with a bioprosthetic material.
    Downey DM; Harre JG; Dolan JP
    Obes Surg; 2005; 15(10):1379-83. PubMed ID: 16354515
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Buttressing staples with cholecyst-derived extracellular matrix (CEM) reinforces staple lines in an ex vivo peristaltic inflation model.
    Burugapalli K; Chan JC; Kelly JL; Pandit A
    Obes Surg; 2008 Nov; 18(11):1418-23. PubMed ID: 18459017
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ex vivo pneumostasis evaluation of a variable-height staple design.
    Contini E; Godek ML; Whiffen JM; Bronson DG
    Innovations (Phila); 2013; 8(4):284-8. PubMed ID: 24145973
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of 5-mm Laparoscopic Stapler to Perform Open Small Bowel Anastomosis in a Neonatal Animal Model.
    Glenn IC; Bruns NE; Ponsky TA
    J Laparoendosc Adv Surg Tech A; 2016 Oct; 26(10):840-844. PubMed ID: 27462959
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Development and Validation of a Fully Automated, Experimental Set-Up for Ex-Vivo Burst Pressure Testing after Surgical Vessel Closure].
    Wallimann H; Menges P; Hausen B; Linder A
    Zentralbl Chir; 2017 Oct; 142(5):457-463. PubMed ID: 28633187
    [No Abstract]   [Full Text] [Related]  

  • 10. Novel endoscopic multi-firing-clip applicator for endoscopic closure of large colonic perforations.
    Ge S; Song C; Yan S; Ai L; Xu J; Li M; Hu B; Cuschieri A
    Minim Invasive Ther Allied Technol; 2016 Aug; 25(4):188-95. PubMed ID: 27218136
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Beyond the "B": a new concept of the surgical staple enabling miniature staplers.
    Demertzis S; Beslac O; Mettler D; Zalokar D; Spangler T; Hausen B; Swanstrom L
    Surg Endosc; 2015 Dec; 29(12):3674-84. PubMed ID: 25795379
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Profiling Surgical Staplers: Does Staple Direction Affect the Strength of the Anastomosis.
    Kimura M; Takahashi H; Tanaka T; Sagawa H; Takeyama H
    Dig Surg; 2015; 32(6):454-8. PubMed ID: 26488286
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparison of burst pressure between buttressed versus non-buttressed staple-lines in an animal model.
    Arnold W; Shikora SA
    Obes Surg; 2005 Feb; 15(2):164-71. PubMed ID: 15802057
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gastrointestinal staple line reinforcement.
    Downey DM; Ali S; Goldblatt MI; Saxe JM; Dolan JP
    Surg Technol Int; 2007; 16():55-60. PubMed ID: 17429769
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intestinal mucosa staple line integrity and anastomotic leak pressure after healing in a porcine model.
    Naoi D; Horie H; Koinuma K; Kumagai Y; Ota G; Tojo M; Kaneda Y; Hishikawa S; Sadatomo A; Inoue Y; Fukushima N; Lefor AK; Sata N
    Surg Today; 2021 Oct; 51(10):1713-1719. PubMed ID: 33743053
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Endoluminal compression clip: full-thickness resection of the mesenteric bowel wall in a porcine model.
    Kopelman Y; Siersema PD; Nir Y; Szold A; Bapaye A; Segol O; Willenz EP; Lelcuk S; Geller A; Kopelman D
    Gastrointest Endosc; 2009 Dec; 70(6):1146-57. PubMed ID: 19647245
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Can LigaSureā„¢ be used to perform sleeve gastrectomy? - Tensile strength and histological changes.
    Lopez J; Vilallonga R; Targarona EM; Balague C; Enriquez L; Rivera R; Balibrea JM; Perez-Ochoa F; Rodriguez K; Baeza M; Reyes A
    Minim Invasive Ther Allied Technol; 2014 Jun; 23(3):144-51. PubMed ID: 24359311
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improving the side-to-side stapled anastomosis: comparison of staplers for robust crotch formation.
    Kimura M; Kuwabara Y; Taniwaki S; Mitsui A; Shibata Y; Ueno S
    Surg Obes Relat Dis; 2018 Jan; 14(1):16-21. PubMed ID: 29108894
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Interrupted coalescent nitinol clip versus continuous suture coronary anastomosis: a comparative endothelial function study.
    Demaria RG; Fortier S; Malo O; Carrier M; Perrault LP
    Heart Surg Forum; 2003; 6(2):72-6. PubMed ID: 12716585
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Single Institution Review of Initial Application of a 5-mm Stapler.
    Rogers AP; Zens TJ; Kohler JE; Le HD; Nichol PF; Leys CM
    J Laparoendosc Adv Surg Tech A; 2016 Aug; 26(8):660-2. PubMed ID: 27398952
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.