These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 31233845)

  • 1. Implementation of real-time and in-line feedback control for a fluid bed granulation process.
    Reimers T; Thies J; Stöckel P; Dietrich S; Pein-Hackelbusch M; Quodbach J
    Int J Pharm; 2019 Aug; 567():118452. PubMed ID: 31233845
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of in-line particle measurement with an SFT-probe as monitoring tool for process automation using a new time-based buffer approach.
    Reimers T; Thies J; Dietrich S; Quodbach J; Pein-Hackelbusch M
    Eur J Pharm Sci; 2019 Feb; 128():162-170. PubMed ID: 30517882
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Study of granule growth kinetics during in situ fluid bed melt granulation using in-line FBRM and SFT probes.
    Kukec S; Hudovornik G; Dreu R; Vrečer F
    Drug Dev Ind Pharm; 2014 Jul; 40(7):952-9. PubMed ID: 23662716
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Real-time feedback control of twin-screw wet granulation based on image analysis.
    Madarász L; Nagy ZK; Hoffer I; Szabó B; Csontos I; Pataki H; Démuth B; Szabó B; Csorba K; Marosi G
    Int J Pharm; 2018 Aug; 547(1-2):360-367. PubMed ID: 29879507
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of in line monitored fluid bed granulation process parameters on the stability of Ethinylestradiol.
    Roßteuscher-Carl K; Fricke S; Hacker MC; Schulz-Siegmund M
    Int J Pharm; 2015 Dec; 496(2):751-8. PubMed ID: 26541302
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Focused beam reflectance method as an innovative (PAT) tool to monitor in-line granulation process in fluidized bed.
    Alshihabi F; Vandamme T; Betz G
    Pharm Dev Technol; 2013 Feb; 18(1):73-84. PubMed ID: 22035287
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In-line monitoring of particle size in a fluid bed granulator: investigations concerning positioning and configuration of the sensor.
    Roßteuscher-Carl K; Fricke S; Hacker MC; Schulz-Siegmund M
    Int J Pharm; 2014 May; 466(1-2):31-7. PubMed ID: 24589125
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Process analytical tools for monitoring, understanding, and control of pharmaceutical fluidized bed granulation: A review.
    Burggraeve A; Monteyne T; Vervaet C; Remon JP; De Beer T
    Eur J Pharm Biopharm; 2013 Jan; 83(1):2-15. PubMed ID: 23041243
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Managing API raw material variability in a continuous manufacturing line - Prediction of process robustness.
    Stauffer F; Vanhoorne V; Pilcer G; Chavez PF; Vervaet C; De Beer T
    Int J Pharm; 2019 Oct; 569():118525. PubMed ID: 31319146
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Near-infrared spectroscopy monitoring and control of the fluidized bed granulation and coating processes-A review.
    Liu R; Li L; Yin W; Xu D; Zang H
    Int J Pharm; 2017 Sep; 530(1-2):308-315. PubMed ID: 28743552
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microscale granulation in a fluid bed powder processor using electrostatic atomisation.
    Kivikero N; Murtomaa M; Ingelbeen B; Antikainen O; Räsänen E; Mannermaa JP; Juppo AM
    Eur J Pharm Biopharm; 2009 Jan; 71(1):130-7. PubMed ID: 18703138
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Combining microwave resonance technology to multivariate data analysis as a novel PAT tool to improve process understanding in fluid bed granulation.
    Lourenço V; Herdling T; Reich G; Menezes JC; Lochmann D
    Eur J Pharm Biopharm; 2011 Aug; 78(3):513-21. PubMed ID: 21333737
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Spray granulation for drug formulation.
    Loh ZH; Er DZ; Chan LW; Liew CV; Heng PW
    Expert Opin Drug Deliv; 2011 Dec; 8(12):1645-61. PubMed ID: 22097906
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel approach to support formulation design on twin screw wet granulation technology: Understanding the impact of overarching excipient properties on drug product quality attributes.
    Willecke N; Szepes A; Wunderlich M; Remon JP; Vervaet C; De Beer T
    Int J Pharm; 2018 Jul; 545(1-2):128-143. PubMed ID: 29684559
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An investigation into the effect of formulation variables and process parameters on characteristics of granules obtained by in situ fluidized hot melt granulation.
    Mašić I; Ilić I; Dreu R; Ibrić S; Parojčić J; Durić Z
    Int J Pharm; 2012 Feb; 423(2):202-12. PubMed ID: 22197773
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of in-line spatial filter velocimetry as PAT monitoring tool for particle growth during fluid bed granulation.
    Burggraeve A; Van Den Kerkhof T; Hellings M; Remon JP; Vervaet C; De Beer T
    Eur J Pharm Biopharm; 2010 Sep; 76(1):138-46. PubMed ID: 20554021
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Empirical prediction model based process optimization for droplet size and spraying angle during pharmaceutical fluidized bed granulation.
    Zeng J; Ming L; Wang J; Huang T; Liu B; Feng L; Xue M; Chen J; Du RF; Feng Y
    Pharm Dev Technol; 2020 Jul; 25(6):720-728. PubMed ID: 32129125
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Predicting particle size during fluid bed granulation using process measurement data.
    Närvänen T; Antikainen O; Yliruusi J
    AAPS PharmSciTech; 2009; 10(4):1268-75. PubMed ID: 19876742
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Batch statistical process control of a fluid bed granulation process using in-line spatial filter velocimetry and product temperature measurements.
    Burggraeve A; Van den Kerkhof T; Hellings M; Remon JP; Vervaet C; De Beer T
    Eur J Pharm Sci; 2011 Apr; 42(5):584-92. PubMed ID: 21397688
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimization of a high shear wet granulation process using focused beam reflectance measurement and particle vision microscope technologies.
    Arp Z; Smith B; Dycus E; O'grady D
    J Pharm Sci; 2011 Aug; 100(8):3431-3440. PubMed ID: 21452298
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.