109 related articles for article (PubMed ID: 31233968)
1. A PEPT algorithm for predefined positions of radioisotopes relative to the tracer particle.
Odo AE; Govender I; Buffler A; Franzidis JP
Appl Radiat Isot; 2019 Sep; 151():299-309. PubMed ID: 31233968
[TBL] [Abstract][Full Text] [Related]
2. Standard method for performing positron emission particle tracking (PEPT) measurements of froth flotation at PEPT Cape Town.
Cole K; Barker DJ; Brito-Parada PR; Buffler A; Hadler K; Mackay I; Mesa D; Morrison AJ; Neethling S; Norori-McCormac A; Shean B; Cilliers J
MethodsX; 2022; 9():101680. PubMed ID: 35449879
[TBL] [Abstract][Full Text] [Related]
3. In vivo real-time positron emission particle tracking (PEPT) and single particle PET.
Pellico J; Vass L; Carrascal-Miniño A; Man F; Kim J; Sunassee K; Parker D; Blower PJ; Marsden PK; T M de Rosales R
Nat Nanotechnol; 2024 May; 19(5):668-676. PubMed ID: 38242986
[TBL] [Abstract][Full Text] [Related]
4. An expectation-maximization algorithm for positron emission particle tracking.
Manger S; Renaud A; Vanneste J
Rev Sci Instrum; 2021 Aug; 92(8):085102. PubMed ID: 34470431
[TBL] [Abstract][Full Text] [Related]
5. Positron Emission Particle Tracking of Granular Flows.
Windows-Yule CRK; Seville JPK; Ingram A; Parker DJ
Annu Rev Chem Biomol Eng; 2020 Jun; 11():367-396. PubMed ID: 32228041
[TBL] [Abstract][Full Text] [Related]
6. Positron emission particle tracking and its application to granular media.
Parker DJ
Rev Sci Instrum; 2017 May; 88(5):051803. PubMed ID: 28571461
[TBL] [Abstract][Full Text] [Related]
7. Three-dimensional spatiotemporal tracking of fluorine-18 radiolabeled yeast cells via positron emission particle tracking.
Langford ST; Wiggins CS; Santos R; Hauser M; Becker JM; Ruggles AE
PLoS One; 2017; 12(7):e0180503. PubMed ID: 28683074
[TBL] [Abstract][Full Text] [Related]
8. Application of Positron Emission Particle Tracking (PEPT) to validate a Discrete Element Method (DEM) model of granular flow and mixing in the Turbula mixer.
Marigo M; Davies M; Leadbeater T; Cairns DL; Ingram A; Stitt EH
Int J Pharm; 2013 Mar; 446(1-2):46-58. PubMed ID: 23376506
[TBL] [Abstract][Full Text] [Related]
9. Effect of Retrofit Design Modifications on the Macroturbulence of a Three-Phase Flotation Tank-Flow Characterization Using Positron Emission Particle Tracking (PEPT).
Cole K; Mesa D; van Heerden M; Brito-Parada PR
Ind Eng Chem Res; 2023 May; 62(19):7580-7591. PubMed ID: 37223719
[TBL] [Abstract][Full Text] [Related]
10. Numerical simulation and PEPT measurements of a 3D conical helical-blade mixer: a high potential solids mixer for solid-state fermentation.
Schutyser MA; Briels WJ; Rinzema A; Boom RM
Biotechnol Bioeng; 2003 Oct; 84(1):29-39. PubMed ID: 12910540
[TBL] [Abstract][Full Text] [Related]
11. Single-particle motion in three-dimensional vibrofluidized granular beds.
Wildman RD; Huntley JM; Hansen JP; Parker DJ; Allen DA
Phys Rev E Stat Phys Plasmas Fluids Relat Interdiscip Topics; 2000 Sep; 62(3 Pt B):3826-35. PubMed ID: 11088900
[TBL] [Abstract][Full Text] [Related]
12. Interpretation of environmental tracers in groundwater systems with stagnant water zones.
Maloszewski P; Stichler W; Zuber A
Isotopes Environ Health Stud; 2004 Mar; 40(1):21-33. PubMed ID: 15085981
[TBL] [Abstract][Full Text] [Related]
13. Single-cell tracking with PET using a novel trajectory reconstruction algorithm.
Lee KS; Kim TJ; Pratx G
IEEE Trans Med Imaging; 2015 Apr; 34(4):994-1003. PubMed ID: 25423651
[TBL] [Abstract][Full Text] [Related]
14. Recent advances in positron emission particle tracking: a comparative review.
Windows-Yule CRK; Herald MT; Nicuşan AL; Wiggins CS; Pratx G; Manger S; Odo AE; Leadbeater T; Pellico J; de Rosales RTM; Renaud A; Govender I; Carasik LB; Ruggles AE; Kokalova-Wheldon T; Seville JPK; Parker DJ
Rep Prog Phys; 2022 Jan; 85(1):. PubMed ID: 34814127
[TBL] [Abstract][Full Text] [Related]
15. Input-output analysis of in vivo photoassimilate translocation using Positron-Emitting Tracer Imaging System (PETIS) data.
Keutgen AJ; Keutgen N; Matsuhashi S; Mizuniwa C; Ito T; Fujimura T; Ishioka NS; Watanabe S; Osa A; Sekine T; Uchida H; Tsuji A; Hashimoto S
J Exp Bot; 2005 May; 56(415):1419-25. PubMed ID: 15809281
[TBL] [Abstract][Full Text] [Related]
16. Simultaneous in-vivo receptor occupancy assays for serotonin 1A, 2A, and dopamine 2 receptors with the use of non-radiolabelled tracers: Proposed method in screening antipsychotics.
Thentu JB; Nirogi R; Bhyrapuneni G; Ajjala DR; Aleti RR; Palacharla RC
J Pharmacol Toxicol Methods; 2017; 85():22-28. PubMed ID: 28063918
[TBL] [Abstract][Full Text] [Related]
17. Nonlinear response and emerging nonequilibrium microstructures for biased diffusion in confined crowded environments.
Bénichou O; Illien P; Oshanin G; Sarracino A; Voituriez R
Phys Rev E; 2016 Mar; 93(3):032128. PubMed ID: 27078313
[TBL] [Abstract][Full Text] [Related]
18. Influence of proton and essential histidyl residues on the transport kinetics of the H+/peptide cotransport systems in intestine (PEPT 1) and kidney (PEPT 2).
Brandsch M; Brandsch C; Ganapathy ME; Chew CS; Ganapathy V; Leibach FH
Biochim Biophys Acta; 1997 Mar; 1324(2):251-62. PubMed ID: 9092712
[TBL] [Abstract][Full Text] [Related]
19. "Label and go"--a fast and easy radiolabelling method for pellets.
Philippe C; Mien LK; Salar-Behzadi S; Knäusl B; Wadsak W; Dudczak R; Kletter K; Viernstein H; Mitterhauser M
Appl Radiat Isot; 2010 Mar; 68(3):399-403. PubMed ID: 20022514
[TBL] [Abstract][Full Text] [Related]
20. Fast 3D-EM reconstruction using Planograms for stationary planar positron emission mammography camera.
Motta A; Guerra AD; Belcari N; Moehrs S; Panetta D; Righi S; Valentini D
Comput Med Imaging Graph; 2005 Dec; 29(8):587-96. PubMed ID: 16290284
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]