These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 31254656)

  • 41. The Assessment of Nipple Areola Complex Sensation with Semmes-Weinstein Monofilaments-Normative Values and Its Covariates.
    Kasielska-Trojan A; Szulia A; Zawadzki T; Antoszewski B
    Diagnostics (Basel); 2021 Nov; 11(11):. PubMed ID: 34829492
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Tactile sensory and pain thresholds in the face and tongue of subjects asymptomatic for oro-facial pain and headache.
    Okayasu I; Komiyama O; Ayuse T; De Laat A
    J Oral Rehabil; 2014 Dec; 41(12):875-80. PubMed ID: 25041286
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Intravenous angiocatheters as a novel alternative to Semmes-Weinstein monofilament evaluation in testing protective sensation.
    Hire JM; Ramadorai UE; Contractor D; Jacobs JM; Bojescul JA; Abell BE
    Mil Med; 2014 Apr; 179(4):442-4. PubMed ID: 24690970
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Relationship between Semmes-Weinstein Monofilaments perception Test and sensory nerve conduction studies in Carpal Tunnel Syndrome.
    Raji P; Ansari NN; Naghdi S; Forogh B; Hasson S
    NeuroRehabilitation; 2014; 35(3):543-52. PubMed ID: 25238864
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Evaluation of Cutaneous Spatial Resolution and Pressure Threshold Secondary to Digital Nerve Repair.
    Klein HJ; Fakin RM; Ducommun P; Giesen T; Giovanoli P; Calcagni M
    Plast Reconstr Surg; 2016 Apr; 137(4):1203-1212. PubMed ID: 27018675
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Intraoral measurement of tactile and filament-prick pain threshold using shortened Semmes-Weinstein monofilaments.
    Komiyama O; Gracely RH; Kawara M; Laat AD
    Clin J Pain; 2008 Jan; 24(1):16-21. PubMed ID: 18180631
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A Comparison of the Sensitivity of Brush Allodynia and Semmes-Weinstein Monofilament Testing in the Detection of Allodynia Within Regions of Secondary Hyperalgesia in Humans.
    Maracle EC; Hung LY; Fell SI; Osmond MR; Brown SH; Srbely JZ
    Pain Pract; 2017 Jan; 17(1):16-24. PubMed ID: 26936430
    [TBL] [Abstract][Full Text] [Related]  

  • 48. A clinical analysis of the recovery from sensory disturbance after sagittal splitting ramus osteotomy using a Semmes-Weinstein pressure aesthesiometer.
    Takasaki Y; Noma H; Masaki H; Fujikawa M; Alberdas JL; Tamura H; Ueda E; Takaki T; Yamane G
    Bull Tokyo Dent Coll; 1998 Aug; 39(3):189-97. PubMed ID: 9927905
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Evaluation of female external genitalia sensitivity to pressure/touch: a preliminary prospective study using Semmes-Weinstein monofilaments.
    Romanzi LJ; Groutz A; Feroz F; Blaivas JG
    Urology; 2001 Jun; 57(6):1145-50. PubMed ID: 11377329
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Sensibility testing in patients with carpal tunnel syndrome.
    Szabo RM; Gelberman RH; Dimick MP
    J Bone Joint Surg Am; 1984 Jan; 66(1):60-4. PubMed ID: 6690444
    [TBL] [Abstract][Full Text] [Related]  

  • 51. The effects of normal human variability and hand activity on sensory testing with the full Semmes-Weinstein monofilaments kit.
    Massy-Westropp N
    J Hand Ther; 2002; 15(1):48-52. PubMed ID: 11866352
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Assessment of sensibility after nerve injury and repair: a systematic review of evidence for validity, reliability and responsiveness of tests.
    Jerosch-Herold C
    J Hand Surg Br; 2005 Jun; 30(3):252-64. PubMed ID: 15862365
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Comparison of sensory testing on different toe surfaces: implications for neuropathy screening.
    Dimitrakoudis D; Bril V
    Neurology; 2002 Aug; 59(4):611-3. PubMed ID: 12196660
    [TBL] [Abstract][Full Text] [Related]  

  • 54. A new device to quantify tactile sensation in neuropathy.
    Kennedy WR; Selim MM; Brink TS; Hodges JS; Wendelschafer-Crabb G; Foster SX; Nolano M; Provitera V; Simone DA
    Neurology; 2011 May; 76(19):1642-9. PubMed ID: 21555731
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Interrater and intrarater reliability of the Semmes Weinstein aesthesiometer to assess touch pressure threshold in burn scars.
    Meirte J; Moortgat P; Truijen S; Maertens K; Lafaire C; De Cuyper L; Hubens G; Van Daele U
    Burns; 2015 Sep; 41(6):1261-7. PubMed ID: 25703663
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Diagnostic accuracy of three sensory tests for diagnosis of sensory disturbances.
    Li XM; Yang Y; Hou Y; Yang JT; Qin BG; Fu G; Gu LQ
    J Reconstr Microsurg; 2015 Jan; 31(1):67-73. PubMed ID: 25423030
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Comparative tactile sensitivity of the fingertip and apical tongue using complex and pure tactile tasks.
    Miles BL; Van Simaeys K; Whitecotton M; Simons CT
    Physiol Behav; 2018 Oct; 194():515-521. PubMed ID: 29981764
    [TBL] [Abstract][Full Text] [Related]  

  • 58. The Effect of Applied Force on Two-Point Discrimination Threshold in the Trigeminal Region.
    Jung JK; Byun JS; Choi JK
    J Oral Facial Pain Headache; 2019; 33(4):371–376. PubMed ID: 31247059
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Altered Semmes-Weinstein monofilament test results are associated with oxidative stress markers in type 2 diabetic subjects.
    Martinez-Hervás S; Mendez MM; Folgado J; Tormos C; Ascaso P; Peiró M; Real JT; Ascaso JF
    J Transl Med; 2017 Sep; 15(1):187. PubMed ID: 28874161
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Quantitative evaluation of neurosensory disturbance after bilateral sagittal split osteotomy using Semmes-Weinstein monofilaments: a systematic review.
    Antonarakis GS; Christou P
    J Oral Maxillofac Surg; 2012 Dec; 70(12):2752-60. PubMed ID: 23010368
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.