BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 31270340)

  • 1. Validation of an apnea and hypopnea detection algorithm implemented in implantable cardioverter defibrillators. The AIRLESS study.
    Defaye P; Mendelson M; Tamisier R; Jacon P; Venier S; Arnol N; Pépin JL
    Sci Rep; 2019 Jul; 9(1):9597. PubMed ID: 31270340
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implantable cardioverter-defibrillator-computed respiratory disturbance index accurately identifies severe sleep apnea: The DASAP-HF study.
    D'Onofrio A; La Rovere MT; Emdin M; Capucci A; Sinagra G; Bianchi V; Pisanò ECL; Pieragnoli P; Tespili M; Luzi M; Talarico A; Zecchin M; Rapacciuolo A; Piacenti M; Indolfi C; Arias MA; Diemberger I; Checchinato C; Boriani G; Padeletti L
    Heart Rhythm; 2018 Feb; 15(2):211-217. PubMed ID: 29017928
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A pacemaker transthoracic impedance sensor with an advanced algorithm to identify severe sleep apnea: the DREAM European study.
    Defaye P; de la Cruz I; Martí-Almor J; Villuendas R; Bru P; Sénéchal J; Tamisier R; Pépin JL
    Heart Rhythm; 2014 May; 11(5):842-8. PubMed ID: 24561163
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Feasibility of automated detection of sleep apnea using implantable pacemakers and defibrillators: a comparison with simultaneous polysomnography recording.
    Della Rocca DG; Albanese M; Placidi F; Forle GB; Di Biase L; Ribatti V; Santini L; Izzi F; Cicchini L; Lovecchio M; Valsecchi S; Lavalle C; Natale A; Mercuri NB; Romigi A
    J Interv Card Electrophysiol; 2019 Dec; 56(3):327-333. PubMed ID: 31646429
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Utility of transthoracic impedance and novel algorithm for sleep apnea screening in pacemaker patient.
    Chen R; Chen K; Dai Y; Zhang S
    Sleep Breath; 2019 Sep; 23(3):741-746. PubMed ID: 30470999
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sleep apnea detection by a cardiac resynchronization device integrated thoracic impedance sensor: A validation study against the gold standard polysomnography.
    Barbieri F; Dichtl W; Heidbreder A; Brandauer E; Stefani A; Adukauskaite A; Senoner T; Schgör W; Hintringer F; Högl B
    PLoS One; 2018; 13(4):e0195573. PubMed ID: 29624601
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Successful screening of sleep-disordered breathing using a pacemaker-based algorithm in Japan.
    Taguchi Y; Matsushita K; Ishikawa T; Matsumoto K; Hosoda J; Iguchi K; Matsushita H; Kubota K; Sumita S; Ishigami T; Tamura K
    J Cardiol; 2019 May; 73(5):394-400. PubMed ID: 30630655
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sleep apnea diagnosis using an ECG Holter device including a nasal pressure (NP) recording: validation of visual and automatic analysis of nasal pressure versus full polysomnography.
    Pépin JL; Defaye P; Vincent E; Christophle-Boulard S; Tamisier R; Lévy P
    Sleep Med; 2009 Jun; 10(6):651-6. PubMed ID: 19028140
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prognostic value of implantable defibrillator-computed respiratory disturbance index: The DASAP-HF study.
    Boriani G; Pisanò ECL; Pieragnoli P; Locatelli A; Capucci A; Talarico A; Zecchin M; Rapacciuolo A; Piacenti M; Indolfi C; Arias MA; Diemberger I; Checchinato C; La Rovere MT; Sinagra G; Emdin M; Ricci RP; D'Onofrio A
    Heart Rhythm; 2021 Mar; 18(3):374-381. PubMed ID: 33283757
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Automatic recognition of abnormal respiratory events during sleep by a pacemaker transthoracic impedance sensor.
    Defaye P; Pépin JL; Poezevara Y; Mabo P; Murgatroyd F; Lévy P; Garrigue S
    J Cardiovasc Electrophysiol; 2004 Sep; 15(9):1034-40. PubMed ID: 15363076
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of upper airway status and respiratory events by a current generation positive airway pressure device.
    Li QY; Berry RB; Goetting MG; Staley B; Soto-Calderon H; Tsai SC; Jasko JG; Pack AI; Kuna ST
    Sleep; 2015 Apr; 38(4):597-605. PubMed ID: 25409101
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Validation study of a polygraphic screening device (BREAS SC20) in the diagnosis of sleep apnea-hypopnea syndrome].
    Núñez R; Rey de Castro J; Socarrás E; Calleja JM; Rubio R; Aizpuru F; Durán-Cantolla J
    Arch Bronconeumol; 2003 Dec; 39(12):537-43. PubMed ID: 14636489
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Importance of cardiac implantable eletronic devices in the diagnosis of Sleep Apnea Syndrome.
    Ribeiro S; Bonito L; Guimarães MJ; Português J; Rodrigues B; Alves A; Durães C; Ferreira D; Sanfins V; Lourenço A
    Rev Port Cardiol (Engl Ed); 2019 Jun; 38(6):451-455. PubMed ID: 31320221
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Oxygen desaturation index from nocturnal oximetry: a sensitive and specific tool to detect sleep-disordered breathing in surgical patients.
    Chung F; Liao P; Elsaid H; Islam S; Shapiro CM; Sun Y
    Anesth Analg; 2012 May; 114(5):993-1000. PubMed ID: 22366847
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Value of pulse oximetry watch for diagnosing pediatric obstructive sleep apnea/hypopnea syndrome.
    Ma JR; Huang JJ; Chen Q; Wu HT; Xiao KL; Zhang YT
    Acta Otolaryngol; 2018 Feb; 138(2):175-179. PubMed ID: 28990830
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Usefulness of sleep-disordered breathing to predict occurrence of appropriate and inappropriate implantable-cardioverter defibrillator therapy in patients with implantable cardioverter-defibrillator for primary prevention of sudden cardiac death.
    Kreuz J; Skowasch D; Horlbeck F; Atzinger C; Schrickel JW; Lorenzen H; Nickenig G; Schwab JO
    Am J Cardiol; 2013 May; 111(9):1319-23. PubMed ID: 23411108
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pacemaker guided screening for severe sleep apnea, a possible option for patients with atrial fibrillation: A systematic review and meta-analysis.
    Wyckmans M; Tukanov E; Winters R; Stinissen R; Vermeulen H; Dendale P; Desteghe L
    Pacing Clin Electrophysiol; 2021 Aug; 44(8):1421-1431. PubMed ID: 33959988
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quality and Safety in Health Care, Part XLIV: Cardiac Resynchronization Therapy and Subcutaneous Defibrillator Implantable Devices.
    Harolds JA
    Clin Nucl Med; 2019 Feb; 44(2):119-120. PubMed ID: 29762239
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Utility of new-generation pacemakers in sleep apnea screening.
    Dias M; Gonçalves I; Amann B; Marques P; Martinho C; Leitão C; Basto RP; de Sousa J; Pinto P; Bárbara C
    Sleep Med; 2017 Sep; 37():27-31. PubMed ID: 28899536
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reliability and accuracy of sleep apnea scans in novel cardiac resynchronization therapy devices: an independent report of two cases.
    Fox H; Nölker G; Gutleben KJ; Bitter T; Horstkotte D; Oldenburg O
    Herzschrittmacherther Elektrophysiol; 2014 Mar; 25(1):53-5. PubMed ID: 24519661
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.