482 related articles for article (PubMed ID: 31272669)
1. Impact of Leaflet Laceration on Transcatheter Aortic Valve-in-Valve Washout: BASILICA to Solve Neosinus and Sinus Stasis.
Hatoum H; Maureira P; Lilly S; Dasi LP
JACC Cardiovasc Interv; 2019 Jul; 12(13):1229-1237. PubMed ID: 31272669
[TBL] [Abstract][Full Text] [Related]
2. Impact of BASILICA on Sinus and Neo-Sinus Hemodynamics after Valve-in-Valve with and without Coronary Flow.
Hatoum H; Maureira P; Lilly S; Dasi LP
Cardiovasc Revasc Med; 2020 Mar; 21(3):271-276. PubMed ID: 31281093
[TBL] [Abstract][Full Text] [Related]
3. The BASILICA Trial: Prospective Multicenter Investigation of Intentional Leaflet Laceration to Prevent TAVR Coronary Obstruction.
Khan JM; Greenbaum AB; Babaliaros VC; Rogers T; Eng MH; Paone G; Leshnower BG; Reisman M; Satler L; Waksman R; Chen MY; Stine AM; Tian X; Dvir D; Lederman RJ
JACC Cardiovasc Interv; 2019 Jul; 12(13):1240-1252. PubMed ID: 31202947
[TBL] [Abstract][Full Text] [Related]
4. Effect of leaflet laceration on transcatheter aortic valve replacement fluid mechanics and comparison with surgical aortic valve replacement.
Sadri V; Kohli K; Ncho B; Inci EK; Perdoncin E; Lisko JC; Lederman R; Greenbaum AB; Babaliaros V; Yoganathan AP
J Thorac Cardiovasc Surg; 2023 Oct; 166(4):e130-e141. PubMed ID: 37086238
[TBL] [Abstract][Full Text] [Related]
5. Pachyderm-Shape Guiding Catheters to Simplify BASILICA Leaflet Traversal.
Lisko JC; Babaliaros VC; Lederman RJ; Khan JM; Rogers T; Greenbaum AB
Cardiovasc Revasc Med; 2019 Sep; 20(9):782-785. PubMed ID: 31257172
[TBL] [Abstract][Full Text] [Related]
6. Preventing Coronary Obstruction During Transcatheter Aortic Valve Replacement: From Computed Tomography to BASILICA.
Lederman RJ; Babaliaros VC; Rogers T; Khan JM; Kamioka N; Dvir D; Greenbaum AB
JACC Cardiovasc Interv; 2019 Jul; 12(13):1197-1216. PubMed ID: 31272666
[TBL] [Abstract][Full Text] [Related]
7. Bioprosthetic Valve Leaflet Displacement During Valve-in-Valve Intervention: An Ex Vivo Bench Study.
Hensey M; Sellers S; Sathananthan J; Lai A; Landes U; Alkhodair A; McManus B; Cheung A; Wood D; Blanke P; Leipsic J; Ye J; Webb J
JACC Cardiovasc Interv; 2020 Mar; 13(6):667-678. PubMed ID: 32113932
[TBL] [Abstract][Full Text] [Related]
8. Leaflet Laceration to Improve Neosinus and Sinus Flow After Valve-in-Valve.
Hatoum H; Maureira P; Lilly S; Dasi LP
Circ Cardiovasc Interv; 2019 Mar; 12(3):e007739. PubMed ID: 30841710
[No Abstract] [Full Text] [Related]
9. Neosinus and Sinus Flow After Self-Expanding and Balloon-Expandable Transcatheter Aortic Valve Replacement.
Hatoum H; Gooden SCM; Sathananthan J; Sellers S; Kutting M; Marx P; Lilly SM; Ihdayhid AR; Thourani VH; Dasi LP
JACC Cardiovasc Interv; 2021 Dec; 14(24):2657-2666. PubMed ID: 34838462
[TBL] [Abstract][Full Text] [Related]
10. Coronary ostial eccentricity in severe aortic stenosis: Guidance for BASILICA transcatheter leaflet laceration.
Komatsu I; Leipsic J; Webb JG; Blanke P; Mackensen GB; Don CW; McCabe JM; Rumer C; Tan CW; Levin DB; Ramos M; Aldea GS; Reisman M; Wijeysundera HC; Radhakrishnan S; Sathananthan J; Piazza N; Kornowski R; Dvir D
J Cardiovasc Comput Tomogr; 2020; 14(6):516-519. PubMed ID: 32199758
[TBL] [Abstract][Full Text] [Related]
11. Transcatheter Laceration of Aortic Leaflets to Prevent Coronary Obstruction During Transcatheter Aortic Valve Replacement: Concept to First-in-Human.
Khan JM; Dvir D; Greenbaum AB; Babaliaros VC; Rogers T; Aldea G; Reisman M; Mackensen GB; Eng MHK; Paone G; Wang DD; Guyton RA; Devireddy CM; Schenke WH; Lederman RJ
JACC Cardiovasc Interv; 2018 Apr; 11(7):677-689. PubMed ID: 29622147
[TBL] [Abstract][Full Text] [Related]
12. Bioprosthetic aortic valve leaflet disruption with high energy electrocautery to prevent coronary artery obstruction during valve-in-valve transcatheter aortic valve replacement.
Nelson BC; Chadderdon S; Song H; Zahr FE
Catheter Cardiovasc Interv; 2019 Jan; 93(1):164-168. PubMed ID: 30298684
[TBL] [Abstract][Full Text] [Related]
13. Neosinus Flow Stasis Correlates With Thrombus Volume Post-TAVR: A Patient-Specific In Vitro Study.
Trusty PM; Sadri V; Madukauwa-David ID; Funnell E; Kamioka N; Sharma R; Makkar R; Babaliaros V; Yoganathan AP
JACC Cardiovasc Interv; 2019 Jul; 12(13):1288-1290. PubMed ID: 31272673
[No Abstract] [Full Text] [Related]
14. Balloon-Augmented Leaflet Modification With Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction and Laceration of the Anterior Mitral Leaflet to Prevent Outflow Obstruction: Benchtop Validation and First In-Man Experience.
Perdoncin E; Bruce CG; Babaliaros VC; Yildirim DK; Depta JP; McCabe JM; Gleason PT; Xie J; Grubb KJ; Paone G; Kohli K; Kamioka N; Khan JM; Rogers T; Lederman RJ; Greenbaum AB
Circ Cardiovasc Interv; 2021 Nov; 14(11):e011028. PubMed ID: 34674556
[TBL] [Abstract][Full Text] [Related]
15. Imaging of Aortic Valve Cusps Using Commissural Alignment: Guidance for Transcatheter Leaflet Laceration With BASILICA.
Komatsu I; Leipsic J; Webb JB; Blanke P; Mackensen GB; Don CW; McCabe JM; Rumer C; Tan CW; Levin DB; Ramos M; Aldea GS; Reisman M; Wijeysundera HC; Radhakrishnan S; Sathananthan J; Piazza N; Kornowski R; Dvir D
JACC Cardiovasc Imaging; 2019 Nov; 12(11 Pt 1):2262-2265. PubMed ID: 31202758
[No Abstract] [Full Text] [Related]
16. Aortic sinus flow stasis likely in valve-in-valve transcatheter aortic valve implantation.
Hatoum H; Moore BL; Maureira P; Dollery J; Crestanello JA; Dasi LP
J Thorac Cardiovasc Surg; 2017 Jul; 154(1):32-43.e1. PubMed ID: 28433356
[TBL] [Abstract][Full Text] [Related]
17. Risk Assessment of Coronary Obstruction During Transcatheter Aortic Valve Replacement: Insights From Post-BASILICA Computed Tomography.
Kitamura M; Wilde J; Dumpies O; Richter I; Obradovic D; Krieghoff C; Gohmann RF; Majunke N; Desch S; Gutberlet M; Borger M; Marwan M; Thiele H; Holzhey D; Abdel-Wahab M
JACC Cardiovasc Interv; 2022 Mar; 15(5):496-507. PubMed ID: 35272774
[TBL] [Abstract][Full Text] [Related]
18. Does Undersizing of Transcatheter Aortic Valve Bioprostheses during Valve-in-Valve Implantation Avoid Coronary Obstruction? An In Vitro Study.
Stock S; Scharfschwerdt M; Meyer-Saraei R; Richardt D; Charitos EI; Sievers HH; Hanke T
Thorac Cardiovasc Surg; 2017 Apr; 65(3):218-224. PubMed ID: 27304222
[No Abstract] [Full Text] [Related]
19. The role of flow stasis in transcatheter aortic valve leaflet thrombosis.
Trusty PM; Bhat SS; Sadri V; Salim MT; Funnell E; Kamioka N; Sharma R; Makkar R; Babaliaros V; Yoganathan AP
J Thorac Cardiovasc Surg; 2022 Sep; 164(3):e105-e117. PubMed ID: 33342573
[TBL] [Abstract][Full Text] [Related]
20. Risk of Coronary Obstruction Due to Sinus Sequestration in Redo Transcatheter Aortic Valve Replacement.
Ochiai T; Oakley L; Sekhon N; Komatsu I; Flint N; Kaewkes D; Yoon SH; Raschpichler M; Patel V; Tiwana R; Enta Y; Mahani S; Kim Y; Stegic J; Chakravarty T; Nakamura M; Cheng W; Makkar R
JACC Cardiovasc Interv; 2020 Nov; 13(22):2617-2627. PubMed ID: 33213747
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]