These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
97 related articles for article (PubMed ID: 3127663)
1. The influence of beam parameters on percentage depth dose in electron arc therapy. Pla M; Pla C; Podgorsak EB Med Phys; 1988; 15(1):49-55. PubMed ID: 3127663 [TBL] [Abstract][Full Text] [Related]
2. Electron dose rate and photon contamination in electron arc therapy. Pla M; Podgorsak EB; Pla C Med Phys; 1989; 16(5):692-7. PubMed ID: 2509864 [TBL] [Abstract][Full Text] [Related]
3. Physical aspects of the angle-beta concept in electron arc therapy. Pla M; Podgorsak EB; Pla C; Freeman CR; Souhami L; Guerra J Int J Radiat Oncol Biol Phys; 1991 Jun; 20(6):1331-9. PubMed ID: 1904412 [TBL] [Abstract][Full Text] [Related]
4. Electron arc dose distributions as a function of beam energy. Olivares-Pla M; Podgorsak EB; Pla C Med Phys; 1997 Jan; 24(1):127-32. PubMed ID: 9029546 [TBL] [Abstract][Full Text] [Related]
5. Application of the electron pencil beam redefinition algorithm to electron arc therapy. Chi PC; Hogstrom KR; Starkschall G; Boyd RA; Tucker SL; Antolak JA Med Phys; 2006 Jul; 33(7):2369-83. PubMed ID: 16898439 [TBL] [Abstract][Full Text] [Related]
6. Electron-beam arc therapy using a high energy betatron. Ruegsegger DR; Lerude SD; Lyle D Radiology; 1979 Nov; 133(2):483-9. PubMed ID: 115060 [TBL] [Abstract][Full Text] [Related]
7. Electron beam characteristics on a Philips SL25. Palta JR; Daftari IK; Ayyangar KM; Suntharalingam N Med Phys; 1990; 17(1):27-34. PubMed ID: 2106612 [TBL] [Abstract][Full Text] [Related]
8. Comparison of electron beam characteristics from multiple accelerators. Followill DS; Davis DS; Ibbott GS Int J Radiat Oncol Biol Phys; 2004 Jul; 59(3):905-10. PubMed ID: 15183494 [TBL] [Abstract][Full Text] [Related]
9. Matching the dosimetry characteristics of a dual-field Stanford technique to a customized single-field Stanford technique for total skin electron therapy. Chen Z; Agostinelli AG; Wilson LD; Nath R Int J Radiat Oncol Biol Phys; 2004 Jul; 59(3):872-85. PubMed ID: 15183491 [TBL] [Abstract][Full Text] [Related]
10. Physical aspects of electron-beam arc therapy. Khan FM; Fullerton GD; Lee JM; Moore VC; Levitt SH Radiology; 1977 Aug; 124(2):497-500. PubMed ID: 406643 [TBL] [Abstract][Full Text] [Related]
11. Effect of electron beam obliquity on lateral buildup ratio: a Monte Carlo dosimetry evaluation. Chow JC; Grigorov GN Phys Med Biol; 2007 Jul; 52(13):3965-77. PubMed ID: 17664588 [TBL] [Abstract][Full Text] [Related]
12. Bremsstrahlung dose to patients in rotational electron therapy. Kase KR; Bjarngard BE Radiology; 1979 Nov; 133(2):531-2. PubMed ID: 115062 [TBL] [Abstract][Full Text] [Related]
13. [Characteristics of thermoluminescent dosimeters for the brehmsstrahlung and electron radiation of the betatron B5M-25]. Popov VI; Motriĭ NIa Med Radiol (Mosk); 1983 Mar; 28(3):49-55. PubMed ID: 6403800 [TBL] [Abstract][Full Text] [Related]
14. Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25. Gerbi BJ; Antolak JA; Deibel FC; Followill DS; Herman MG; Higgins PD; Huq MS; Mihailidis DN; Yorke ED; Hogstrom KR; Khan FM Med Phys; 2009 Jul; 36(7):3239-79. PubMed ID: 19673223 [TBL] [Abstract][Full Text] [Related]
15. Influence of cone design on the electron beam characteristics on clinical accelerators. Kassaee A; Altschuler MD; Ayyalsomayajula S; Bloch P Med Phys; 1994 Nov; 21(11):1671-6. PubMed ID: 7891626 [TBL] [Abstract][Full Text] [Related]
16. Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams. Tzedakis A; Damilakis JE; Mazonakis M; Stratakis J; Varveris H; Gourtsoyiannis N Med Phys; 2004 Apr; 31(4):907-13. PubMed ID: 15125009 [TBL] [Abstract][Full Text] [Related]
17. Choosing a therapy electron accelerator target. Hutcheon RM; Schriber SO; Funk LW; Sherman NK Med Phys; 1979; 6(3):211-5. PubMed ID: 112371 [TBL] [Abstract][Full Text] [Related]
18. Physical aspects of a rotational total skin electron irradiation. Podgorsak EB; Pla C; Pla M; Lefebvre PY; Heese R Med Phys; 1983; 10(2):159-68. PubMed ID: 6408365 [TBL] [Abstract][Full Text] [Related]
19. Characteristics of electron beams from a medical microtron. George RE; Frost SV; Hartson-Eaton M Med Phys; 1986; 13(4):533-8. PubMed ID: 3090411 [TBL] [Abstract][Full Text] [Related]
20. Comparison of broad beam central axis depth dose curves from different accelerators using the universal depth dose curve model. Werner BL Acta Radiol Suppl; 1983; 364():35-41. PubMed ID: 6316738 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]