119 related articles for article (PubMed ID: 31278546)
1. Event-triggered averaging of electrical impedance tomography (EIT) respiratory waveforms as compared to low-pass filtering for removal of cardiac related impedance changes.
Coppadoro A; Eronia N; Foti G; Bellani G
J Clin Monit Comput; 2020 Jun; 34(3):553-558. PubMed ID: 31278546
[TBL] [Abstract][Full Text] [Related]
2. Electrical Impedance Tomography as a monitoring tool during weaning from mechanical ventilation: an observational study during the spontaneous breathing trial.
Wisse JJ; Goos TG; Jonkman AH; Somhorst P; Reiss IKM; Endeman H; Gommers D
Respir Res; 2024 Apr; 25(1):179. PubMed ID: 38664685
[TBL] [Abstract][Full Text] [Related]
3. Automatic protective ventilation using the ARDSNet protocol with the additional monitoring of electrical impedance tomography.
Pomprapa A; Schwaiberger D; Pickerodt P; Tjarks O; Lachmann B; Leonhardt S
Crit Care; 2014 Jun; 18(3):R128. PubMed ID: 24957974
[TBL] [Abstract][Full Text] [Related]
4. Respiratory rate monitoring in ICU patients and healthy volunteers using electrical impedance tomography: a validation study.
Wisse JJ; Flinsenberg MJW; Jonkman AH; Goos TG; Gommers D
Physiol Meas; 2024 Jun; 45(5):. PubMed ID: 38588677
[No Abstract] [Full Text] [Related]
5. Absolute electrical impedance tomography (aEIT) guided ventilation therapy in critical care patients: simulations and future trends.
Denaï MA; Mahfouf M; Mohamad-Samuri S; Panoutsos G; Brown BH; Mills GH
IEEE Trans Inf Technol Biomed; 2010 May; 14(3):641-9. PubMed ID: 19906599
[TBL] [Abstract][Full Text] [Related]
6. Visualizing pursed lips breathing of patients with chronic obstructive pulmonary disease through evaluation of global and regional ventilation using electrical impedance tomography.
Yang L; Gao Z; Cao X; Wang C; Wang H; Dai J; Liu Y; Qin Y; Dai M; Zhang B; Zhao K; Zhao Z
Physiol Meas; 2024 Apr; 45(4):. PubMed ID: 38479002
[No Abstract] [Full Text] [Related]
7. Distribution of regional lung function in upright healthy subjects determined by electrical impedance tomography in two chest examination planes.
Frerichs I; Vogt B; Deuss K; Hennig V; Schädler D; Händel C
Physiol Meas; 2024 Jan; 45(1):. PubMed ID: 38096575
[No Abstract] [Full Text] [Related]
8. Improved filtering methods to suppress cardiovascular contamination in electrical impedance tomography recordings.
Wisse JJ; Somhorst P; Behr J; van Nieuw Amerongen AR; Gommers D; Jonkman AH
Physiol Meas; 2024 May; 45(5):. PubMed ID: 38697210
[No Abstract] [Full Text] [Related]
9. Evaluation of adjacent and opposite current injection patterns for a wearable chest electrical impedance tomography system.
Yang L; Gao Z; Wang C; Wang H; Dai J; Liu Y; Qin Y; Dai M; Cao X; Zhao Z
Physiol Meas; 2024 Feb; 45(2):. PubMed ID: 38266301
[No Abstract] [Full Text] [Related]
10. Review of electrical impedance tomography in the pediatric patient.
Cabezudo Ballesteros S; Sanabria Carretero P; Reinoso Barbero F
Rev Esp Anestesiol Reanim (Engl Ed); 2024; 71(6):479-485. PubMed ID: 38458492
[TBL] [Abstract][Full Text] [Related]
11. Validation of three-dimensional thoracic electrical impedance tomography of horses during normal and increased tidal volumes.
Byrne DP; Studer N; Secombe C; Cieslewicz A; Hosgood G; Raisis A; Adler A; Mosing M
Physiol Meas; 2024 Mar; 45(3):. PubMed ID: 38422515
[No Abstract] [Full Text] [Related]
12. [The mechanical ventilation guided by electrical impedance tomography in acute respiratory distress syndrome].
Sun Q; Liu L; Yang Y
Zhonghua Yi Xue Za Zhi; 2024 Apr; 104(15):1247-1252. PubMed ID: 38637164
[TBL] [Abstract][Full Text] [Related]
13. Can bronchoconstriction and bronchodilatation in horses be detected using electrical impedance tomography?
Secombe C; Adler A; Hosgood G; Raisis A; Mosing M
J Vet Intern Med; 2021 Jul; 35(4):2035-2044. PubMed ID: 33977584
[TBL] [Abstract][Full Text] [Related]
14. Estimating regions of air trapping from electrical impedance tomography data.
Mueller JL; Muller P; Mellenthin M; Murthy R; Capps M; Alsaker M; Deterding R; Sagel SD; DeBoer E
Physiol Meas; 2018 May; 39(5):05NT01. PubMed ID: 29726838
[TBL] [Abstract][Full Text] [Related]
15. Electrical impedance tomography in anaesthetised chickens (
Wong AM; Lum HY; Musk GC; Hyndman TH; Waldmann AD; Monks DJ; Bowden RS; Mosing M
Front Vet Sci; 2024; 11():1202931. PubMed ID: 38545561
[TBL] [Abstract][Full Text] [Related]
16. Functional validation and comparison framework for EIT lung imaging.
Grychtol B; Elke G; Meybohm P; Weiler N; Frerichs I; Adler A
PLoS One; 2014; 9(8):e103045. PubMed ID: 25110887
[TBL] [Abstract][Full Text] [Related]
17. [Application of electrical impedance tomography imaging technology combined with generative adversarial network in pulmonary ventilation monitoring].
Zhao M; Liu J; Guo Z; Chen X; Zhang S; Zheng T
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2024 Feb; 41(1):105-113. PubMed ID: 38403610
[TBL] [Abstract][Full Text] [Related]
18. Impact of model shape mismatch on reconstruction quality in electrical impedance tomography.
Grychtol B; Lionheart WR; Bodenstein M; Wolf GK; Adler A
IEEE Trans Med Imaging; 2012 Sep; 31(9):1754-60. PubMed ID: 22645263
[TBL] [Abstract][Full Text] [Related]
19. Electrical Impedance Tomography-based Ventilation Patterns in Patients after Major Surgery.
Iwata H; Yoshida T; Hoshino T; Aiyama Y; Maezawa T; Hashimoto H; Koyama Y; Yamada T; Fujino Y
Am J Respir Crit Care Med; 2024 Jun; 209(11):1328-1337. PubMed ID: 38346178
[No Abstract] [Full Text] [Related]
20. Influence of a Structural Prior Mask on EIT Image Reconstruction.
Chen R; Krueger-Ziolek S; Battistel A; Jalal NA; Rupitsch SJ; Moeller K
Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-4. PubMed ID: 38083310
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]