196 related articles for article (PubMed ID: 31278575)
1. How patient off-centering impacts organ dose and image noise in pediatric head and thoracoabdominal CT.
Euler A; Saltybaeva N; Alkadhi H
Eur Radiol; 2019 Dec; 29(12):6790-6793. PubMed ID: 31278575
[TBL] [Abstract][Full Text] [Related]
2. Vertical off-centering affects organ dose in chest CT: Evidence from Monte Carlo simulations in anthropomorphic phantoms.
Saltybaeva N; Alkadhi H
Med Phys; 2017 Nov; 44(11):5697-5704. PubMed ID: 28817195
[TBL] [Abstract][Full Text] [Related]
3. Effect of vertical positioning on organ dose, image noise and contrast in pediatric chest CT--phantom study.
Kaasalainen T; Palmu K; Lampinen A; Kortesniemi M
Pediatr Radiol; 2013 Jun; 43(6):673-84. PubMed ID: 23341090
[TBL] [Abstract][Full Text] [Related]
4. The effect of head size∕shape, miscentering, and bowtie filter on peak patient tissue doses from modern brain perfusion 256-slice CT: how can we minimize the risk for deterministic effects?
Perisinakis K; Seimenis I; Tzedakis A; Papadakis AE; Damilakis J
Med Phys; 2013 Jan; 40(1):011911. PubMed ID: 23298102
[TBL] [Abstract][Full Text] [Related]
5. Effect of patient centering on patient dose and image noise in chest CT.
Kaasalainen T; Palmu K; Reijonen V; Kortesniemi M
AJR Am J Roentgenol; 2014 Jul; 203(1):123-30. PubMed ID: 24951205
[TBL] [Abstract][Full Text] [Related]
6. Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality.
Papadakis AE; Damilakis J
Invest Radiol; 2019 May; 54(5):265-272. PubMed ID: 30562273
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of an organ-based tube current modulation tool in pediatric CT examinations.
Papadakis AE; Damilakis J
Eur Radiol; 2020 Oct; 30(10):5728-5737. PubMed ID: 32435930
[TBL] [Abstract][Full Text] [Related]
8. The impact of vertical off-centering on image noise and breast dose in chest CT with organ-based tube current modulation: A phantom study.
Mäkelä T; Kortesniemi M; Kaasalainen T
Phys Med; 2022 Aug; 100():153-163. PubMed ID: 35853275
[TBL] [Abstract][Full Text] [Related]
9. Vertical Off-Centering in Reduced Dose Chest-CT: Impact on Effective Dose and Image Noise Values.
Eberhard M; Blüthgen C; Barth BK; Frauenfelder T; Saltybaeva N; Martini K
Acad Radiol; 2020 Apr; 27(4):508-517. PubMed ID: 31358357
[TBL] [Abstract][Full Text] [Related]
10. [Influence of Bowtie Filter and Patient Positioning on In-plane Dose Distribution and Image Quality in ECG-gated CT].
Minami K; Matsubara K; Hayashi Y; Fujiwara Y; Morimoto K; Kobatake T
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(6):536-545. PubMed ID: 31217404
[TBL] [Abstract][Full Text] [Related]
11. Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality.
Papadakis AE; Perisinakis K; Damilakis J
Eur Radiol; 2014 Oct; 24(10):2520-31. PubMed ID: 25027840
[TBL] [Abstract][Full Text] [Related]
12. The effects of mis-centering on radiation dose during CT head examination: A phantom study.
Isa INC; Rahmat SMS; Dom SM; Kayun Z; Karim MKA
J Xray Sci Technol; 2019; 27(4):631-639. PubMed ID: 31205011
[TBL] [Abstract][Full Text] [Related]
13. Radiation dose reduction to the breast in thoracic CT: comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current.
Wang J; Duan X; Christner JA; Leng S; Yu L; McCollough CH
Med Phys; 2011 Nov; 38(11):6084-92. PubMed ID: 22047373
[TBL] [Abstract][Full Text] [Related]
14. Point Organ Radiation Dose in Abdominal CT: Effect of Patient Off-Centering in an Experimental Human Cadaver Study.
Ali Khawaja RD; Singh S; Padole A; Otrakji A; Lira D; Zhang D; Liu B; Primak A; Xu G; Kalra MK
Radiat Prot Dosimetry; 2017 Aug; 175(4):440-449. PubMed ID: 28074019
[TBL] [Abstract][Full Text] [Related]
15. The influence of patient centering on CT dose and image noise.
Toth T; Ge Z; Daly MP
Med Phys; 2007 Jul; 34(7):3093-101. PubMed ID: 17822016
[TBL] [Abstract][Full Text] [Related]
16. Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique.
Gandhi D; Crotty DJ; Stevens GM; Schmidt TG
Med Phys; 2015 Nov; 42(11):6572-8. PubMed ID: 26520748
[TBL] [Abstract][Full Text] [Related]
17. The effect of vertical centering and scout direction on automatic tube voltage selection in chest CT: a preliminary phantom study on two different CT equipments.
Kaasalainen T; Mäkelä T; Kortesniemi M
Eur J Radiol Open; 2019; 6():24-32. PubMed ID: 30619916
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of detector readout gain mode and bowtie filters for cone-beam CT imaging of the head.
Xu J; Sisniega A; Zbijewski W; Dang H; Stayman JW; Wang X; Foos DH; Aygun N; Koliatsos VE; Siewerdsen JH
Phys Med Biol; 2016 Aug; 61(16):5973-92. PubMed ID: 27435162
[TBL] [Abstract][Full Text] [Related]
19. Chest CT performed with 3D and z-axis automatic tube current modulation technique: breast and effective doses.
Matsubara K; Takata T; Koshida K; Noto K; Shimono T; Horii J; Yamamoto T; Matsui O
Acad Radiol; 2009 Apr; 16(4):450-5. PubMed ID: 19268857
[TBL] [Abstract][Full Text] [Related]
20. Use of automatic tube current modulation with a standardized noise index in young children undergoing chest computed tomography scans with 64-slice multidetector computed tomography.
Peng Y; Li J; Ma D; Zhang Q; Liu Y; Zeng J; Sun G
Acta Radiol; 2009 Dec; 50(10):1175-81. PubMed ID: 19922316
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]