These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 31283480)

  • 1. Grain Scattering Noise Modeling and Its Use in the Detection and Characterization of Defects Using Ultrasonic Arrays.
    Bai L; Velichko A; Drinkwater BW
    IEEE Trans Ultrason Ferroelectr Freq Control; 2019 Nov; 66(11):1798-1813. PubMed ID: 31283480
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dimensionality reduction of ultrasonic array data for characterization of inclined defects based on supervised locality preserving projection.
    Bai L; Liu M; Liu N; Su X; Lai F; Xu J
    Ultrasonics; 2022 Feb; 119():106625. PubMed ID: 34739950
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Combining Simulated and Experimental Data to Simulate Ultrasonic Array Data From Defects in Materials With High Structural Noise.
    Bloxham HA; Velichko A; Wilcox PD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Dec; 63(12):2198-2206. PubMed ID: 27705856
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ultrasonic signal enhancement for coarse grain materials by machine learning analysis.
    Xu W; Li X; Zhang J; Xue Z; Cao J
    Ultrasonics; 2021 Dec; 117():106550. PubMed ID: 34399134
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ultrasonic defect characterization using parametric-manifold mapping.
    Velichko A; Bai L; Drinkwater BW
    Proc Math Phys Eng Sci; 2017 Jun; 473(2202):20170056. PubMed ID: 28690410
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A New Physically Motivated Clutter Model With Applications to Nondestructive Ultrasonic Testing.
    Rawashdeh Y; Kay S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Aug; 67(8):1679-1690. PubMed ID: 32149629
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measuring predictability in ultrasonic signals: an application to scattering material characterization.
    CarriĆ³n A; Miralles R; Lara G
    Ultrasonics; 2014 Sep; 54(7):1904-11. PubMed ID: 24952468
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Defect characterization using an ultrasonic array to measure the scattering coefficient matrix.
    Zhang J; Drinkwater BW; Wilcox PD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Oct; 55(10):2254-65. PubMed ID: 18986873
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Finite element modeling of grain size effects on the ultrasonic microstructural noise backscattering in polycrystalline materials.
    Bai X; Tie B; Schmitt JH; Aubry D
    Ultrasonics; 2018 Jul; 87():182-202. PubMed ID: 29547790
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Application of Ultrasonic Array Method for the Inspection of TC18 Addictive Manufacturing Titanium Alloy.
    Li W; Zhou Z; Li Y
    Sensors (Basel); 2019 Oct; 19(20):. PubMed ID: 31658623
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Flaw Detection in Highly Scattering Materials Using a Simple Ultrasonic Sensor Employing Adaptive Template Matching.
    Wu B; Huang Y
    Sensors (Basel); 2021 Dec; 22(1):. PubMed ID: 35009809
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of microstructural grain-size distribution on ultrasonic scattering.
    Norouzian M; Islam S; Turner JA
    Ultrasonics; 2020 Mar; 102():106032. PubMed ID: 31670233
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Signal quality enhancement using higher order wavelets for ultrasonic TOFD signals from austenitic stainless steel welds.
    Praveen A; Vijayarekha K; Abraham ST; Venkatraman B
    Ultrasonics; 2013 Sep; 53(7):1288-92. PubMed ID: 23623414
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison between experimental and 2-D numerical studies of multiple scattering in Inconel600 by means of array probes.
    Shahjahan S; Rupin F; Aubry A; Chassignole B; Fouquet T; Derode A
    Ultrasonics; 2014 Jan; 54(1):358-67. PubMed ID: 23880120
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultrasonic backscatter from elongated grains using line focused ultrasound.
    Kube CM; Arguelles AP; Turner JA
    Ultrasonics; 2018 Jan; 82():79-83. PubMed ID: 28759759
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mode-converted ultrasonic scattering in polycrystals with elongated grains.
    Arguelles AP; Kube CM; Hu P; Turner JA
    J Acoust Soc Am; 2016 Sep; 140(3):1570. PubMed ID: 27914376
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Statistics associated with the scattering of ultrasound from microstructure.
    Song Y; Kube CM; Turner JA; Li X
    Ultrasonics; 2017 Sep; 80():58-61. PubMed ID: 28499125
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultrasonic attenuation of polycrystalline materials with a distribution of grain sizes.
    Arguelles AP; Turner JA
    J Acoust Soc Am; 2017 Jun; 141(6):4347. PubMed ID: 28618813
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving Depth Resolution of Ultrasonic Phased Array Imaging to Inspect Aerospace Composite Structures.
    Mohammadkhani R; Zanotti Fragonara L; Padiyar M J; Petrunin I; Raposo J; Tsourdos A; Gray I
    Sensors (Basel); 2020 Jan; 20(2):. PubMed ID: 31968541
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ultrasonic Defect Characterization Using the Scattering Matrix: A Performance Comparison Study of Bayesian Inversion and Machine Learning Schemas.
    Bai L; Le Bourdais F; Miorelli R; Calmon P; Velichko A; Drinkwater BW
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Oct; 68(10):3143-3155. PubMed ID: 34048342
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.