These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 31291136)

  • 21. Effect of decorrelation on 3-D grating detection with static and dynamic random-dot stereograms.
    Palmisano S; Allison RS; Howard IP
    Vision Res; 2006 Jan; 46(1-2):57-71. PubMed ID: 16307771
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Temporal properties of disparity processing revealed by dynamic random-dot stereograms.
    Gheorghiu E; Erkelens CJ
    Perception; 2005; 34(10):1205-19. PubMed ID: 16309115
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Occipital GABA levels in older adults and their relationship to visual perceptual suppression.
    Pitchaimuthu K; Wu QZ; Carter O; Nguyen BN; Ahn S; Egan GF; McKendrick AM
    Sci Rep; 2017 Oct; 7(1):14231. PubMed ID: 29079815
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Assessing differential effects of single and accelerated low-frequency rTMS to the visual cortex on GABA and glutamate concentrations.
    Rafique SA; Steeves JKE
    Brain Behav; 2020 Dec; 10(12):e01845. PubMed ID: 32964685
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Perceptual artifacts in random-dot stereograms.
    Tsirlin I; Wilcox LM; Allison RS
    Perception; 2010; 39(3):349-55. PubMed ID: 20465171
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Reduced prefrontal glutamate/glutamine and gamma-aminobutyric acid levels in major depression determined using proton magnetic resonance spectroscopy.
    Hasler G; van der Veen JW; Tumonis T; Meyers N; Shen J; Drevets WC
    Arch Gen Psychiatry; 2007 Feb; 64(2):193-200. PubMed ID: 17283286
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Form and depth in global stereopsis.
    Chung CS; Berbaum K
    J Exp Psychol Hum Percept Perform; 1984 Apr; 10(2):258-75. PubMed ID: 6232344
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Interhemispherical comparisons in the processing of contour and random texture sinewave stereograms.
    Shipley T; Garfinkel R; van Houten P
    Doc Ophthalmol; 1984 Nov; 58(3):269-305. PubMed ID: 6518980
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Disparity-tuning characteristics of neuronal responses to dynamic random-dot stereograms in macaque visual area V4.
    Tanabe S; Doi T; Umeda K; Fujita I
    J Neurophysiol; 2005 Oct; 94(4):2683-99. PubMed ID: 16000525
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Depth in anticorrelated stereograms: effects of spatial density and interocular delay.
    Cogan AI; Lomakin AJ; Rossi AF
    Vision Res; 1993 Sep; 33(14):1959-75. PubMed ID: 8249313
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Efficiency of stereopsis in random-dot stereograms.
    Harris JM; Parker AJ
    J Opt Soc Am A; 1992 Jan; 9(1):14-24. PubMed ID: 1738046
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Cortical areas mediating stereopsis in the human brain: a PET study.
    Fortin A; Ptito A; Faubert J; Ptito M
    Neuroreport; 2002 May; 13(6):895-8. PubMed ID: 11997709
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Using Functional Near Infrared Spectroscopy (fNIRS) to Study Dynamic Stereoscopic Depth Perception.
    Ward LM; Morison G; Simpson WA; Simmers AJ; Shahani U
    Brain Topogr; 2016 Jul; 29(4):515-23. PubMed ID: 26900069
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Visual persistence of stereoscopic stimuli: electric brain activity without perceptual correlate.
    Skrandies W
    Vision Res; 1987; 27(12):2109-18. PubMed ID: 3447360
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Increased thalamic glutamate/glutamine levels in migraineurs.
    Bathel A; Schweizer L; Stude P; Glaubitz B; Wulms N; Delice S; Schmidt-Wilcke T
    J Headache Pain; 2018 Jul; 19(1):55. PubMed ID: 30019230
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Depth attraction and repulsion in random dot stereograms.
    Stevenson SB; Cormack LK; Schor CM
    Vision Res; 1991; 31(5):805-13. PubMed ID: 2035265
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Systematic distortions of shape from stereopsis.
    Johnston EB
    Vision Res; 1991; 31(7-8):1351-60. PubMed ID: 1891823
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Eye movements and stereopsis during dichoptic viewing of moving random-dot stereograms.
    Erkelens CJ; Collewijn H
    Vision Res; 1985; 25(11):1689-700. PubMed ID: 3832593
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A proton magnetic resonance spectroscopy study of metabolites in the occipital lobes in epilepsy.
    Simister RJ; McLean MA; Barker GJ; Duncan JS
    Epilepsia; 2003 Apr; 44(4):550-8. PubMed ID: 12681004
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Stereopsis and positional acuity under dark adaptation.
    Livingstone MS; Hubel DH
    Vision Res; 1994 Mar; 34(6):799-802. PubMed ID: 8160394
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.