These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 31294748)

  • 21. Microsurgical clipping of previously coiled intracranial aneurysms.
    Nakamura M; Montibeller GR; Götz F; Krauss JK
    Clin Neurol Neurosurg; 2013 Aug; 115(8):1343-9. PubMed ID: 23352715
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of Local Coil Density on Blood Flow Stagnation in Densely Coiled Cerebral Aneurysms: A Computational Study Using a Cartesian Grid Method.
    Otani T; Shindo T; Ii S; Hirata M; Wada S
    J Biomech Eng; 2018 Apr; 140(4):. PubMed ID: 29383379
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Prediction of the extent of thrombus formation in the parent artery after endovascular occlusion of a distal anterior cerebral artery aneurysm using computational fluid dynamics.
    Tanioka S; Ishida F; Kishimoto T; Tanaka K; Shimosaka S; Suzuki H
    J Clin Neurosci; 2020 Apr; 74():210-212. PubMed ID: 31420275
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Fast virtual coiling algorithm for intracranial aneurysms using pre-shape path planning.
    Patel P; Mousavi Janbeh Sarayi SM; Chen D; Hammond AL; Damiano RJ; Davies JM; Xu J; Meng H
    Comput Biol Med; 2021 Jul; 134():104496. PubMed ID: 34077817
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Modeling the Mechanical Microenvironment of Coiled Cerebral Aneurysms.
    Bass DI; Marsh LMM; Fillingham P; Lim D; Chivukula VK; Kim LJ; Aliseda A; Levitt MR
    J Biomech Eng; 2023 Apr; 145(4):. PubMed ID: 36193892
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Stent-assisted coil embolization of a recurrent posterior cerebral artery aneurysm following surgical clipping.
    Takeshita T; Nagamine T; Ishihara K; Kaku Y
    Neuroradiol J; 2017 Feb; 30(1):99-103. PubMed ID: 27903923
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Higher oscillatory shear index is related to aneurysm recanalization after coil embolization in posterior communicating artery aneurysms.
    Kim T; Oh CW; Bang JS; Ban SP; Lee SU; Kim YD; Kwon OK
    Acta Neurochir (Wien); 2021 Aug; 163(8):2327-2337. PubMed ID: 33037924
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The significant impact of framing coils on long-term outcomes in endovascular coiling for intracranial aneurysms: how to select an appropriate framing coil.
    Ishida W; Sato M; Amano T; Matsumaru Y
    J Neurosurg; 2016 Sep; 125(3):705-12. PubMed ID: 26745474
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Causes of early rebleeding after coil embolization of ruptured cerebral aneurysms.
    Kim ST; Baek JW; Lee WH; Lee KS; Kwon WH; Pyo S; Jeong HW; Jeong YG
    Clin Neurol Neurosurg; 2018 Nov; 174():108-116. PubMed ID: 30232054
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Endovascular treatment of intracranial aneurysms: comparative evaluation in a terminal bifurcation aneurysm model in dogs.
    Yoshino Y; Niimi Y; Song JK; Silane M; Berenstein A
    J Neurosurg; 2004 Dec; 101(6):996-1003. PubMed ID: 15597760
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Modeling the interaction of coils with the local blood flow after coil embolization of intracranial aneurysms.
    Cha KS; Balaras E; Lieber BB; Sadasivan C; Wakhloo AK
    J Biomech Eng; 2007 Dec; 129(6):873-79. PubMed ID: 18067391
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Initial experience with an extremely soft bare platinum coil, ED coil-10 Extra Soft, for endovascular treatment of cerebral aneurysms.
    Harada K; Morioka J
    J Neurointerv Surg; 2013 Nov; 5(6):577-81. PubMed ID: 23190564
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Assessing the Hemodynamics in Residual Cavities of Intracranial Aneurysm after Coil Embolization with Combined Computational Flow Dynamics and Silent Magnetic Resonance Angiography.
    Suzuki T; Genkai N; Nomura T; Abe H
    J Stroke Cerebrovasc Dis; 2020 Dec; 29(12):105290. PubMed ID: 32992205
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Quantitative effects of coil packing density on cerebral aneurysm fluid dynamics: an in vitro steady flow study.
    Babiker MH; Gonzalez LF; Albuquerque F; Collins D; Elvikis A; Frakes DH
    Ann Biomed Eng; 2010 Jul; 38(7):2293-301. PubMed ID: 20306135
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A collagen-based coil for embolization of saccular aneurysms in a New Zealand White rabbit model.
    Kallmes DF; Fujiwara NH; Yuen D; Dai D; Li ST
    AJNR Am J Neuroradiol; 2003 Apr; 24(4):591-6. PubMed ID: 12695186
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Neurosurgical management of previously coiled recurrent intracranial aneurysms.
    König RW; Kretschmer T; Antoniadis G; Seitz K; Braun V; Richter HP; Perez de Laborda M; Scheller C; Börm W
    Zentralbl Neurochir; 2007 Feb; 68(1):8-13. PubMed ID: 17487802
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Endovascular coil embolization for unruptured intracranial aneurysms in patients over 80 years of age.
    Lee SW; Kwon HJ; Jeong EO; Koh HS; Kim KH; Choi SW; Kim SH; Youm JY
    J Cerebrovasc Endovasc Neurosurg; 2020 Dec; 22(4):237-244. PubMed ID: 33050684
    [TBL] [Abstract][Full Text] [Related]  

  • 38. In vitro measurement of the permeability of endovascular coils deployed in cerebral aneurysms.
    Sadasivan C; Swartwout E; Kappel AD; Woo HH; Fiorella DJ; Lieber BB
    J Neurointerv Surg; 2018 Sep; 10(9):896-900. PubMed ID: 29298858
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Blood Flow Into Basilar Tip Aneurysms: A Predictor for Recanalization After Coil Embolization.
    Sugiyama S; Niizuma K; Sato K; Rashad S; Kohama M; Endo H; Endo T; Matsumoto Y; Ohta M; Tominaga T
    Stroke; 2016 Oct; 47(10):2541-7. PubMed ID: 27625377
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Progressive thrombosis of small saccular aneurysms filled with contrast immediately after coil embolization: analysis of related factors and long-term follow-up.
    Cho YD; Jeon JP; Rhim JK; Park JJ; Yoo RE; Kang HS; Kim JE; Cho WS; Han MH
    Neuroradiology; 2015 Jun; 57(6):615-23. PubMed ID: 25808124
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.