560 related articles for article (PubMed ID: 31296082)
21. Risk Factors for Closure Failure following Percutaneous Transfemoral Transcatheter Aortic Valve Implantation.
Lee CH; Ko YG; Park Y; Shim CY; Hong GR; Lee SH; Lee S; Jung HW; Hong SJ; Ahn CM; Kim JS; Kim BK; Choi D; Hong MK; Jang Y
Ann Vasc Surg; 2020 Jul; 66():406-414. PubMed ID: 31918036
[TBL] [Abstract][Full Text] [Related]
22. Safety and efficacy of hybrid vascular closure technique using both a suture- and collagen-mediated closure device after transfemoral transcatheter aortic valve implantation.
Al-Ani A; Hoffmann P; von Lueder T; Opdahl A
Catheter Cardiovasc Interv; 2020 May; 95(6):1171-1175. PubMed ID: 31379116
[TBL] [Abstract][Full Text] [Related]
23. Sheath Size Up and Down With Single Proglide - A Technique for Achieving Hemostasis With Use of Large Size Delivery System During Endovascular Graft Placement.
Singh G; Scalise F; Bianchi P; Cireni L; Sorropago G; Casana R; Tolva V
Ann Vasc Surg; 2022 Jan; 78():190-196. PubMed ID: 34464729
[TBL] [Abstract][Full Text] [Related]
24. Single suture-mediated closure system after transfemoral transcatheter aortic valve implantation: A single-center real-world experience.
Iacovelli F; Burattini O; Sturdà F; Branca M; Stabile E; Fimiani L; Salemme L; Cioppa A; Pucciarelli A; Cafaro A; Bortone AS; Contegiacomo G; Pignatelli A; Tesorio T
Catheter Cardiovasc Interv; 2024 Jun; 103(7):1125-1137. PubMed ID: 38639140
[TBL] [Abstract][Full Text] [Related]
25. Alternative Application Technique for the MANTA Vascular Closure Device for Percutaneous Large-Bore Arterial Access Closure: The Fluoroscopic DOT Technique.
Memon S; Goldman S; Rodriguez R; Ramlawi B; Coady PM; Gnall EM
J Endovasc Ther; 2023 Dec; 30(6):885-891. PubMed ID: 35766367
[TBL] [Abstract][Full Text] [Related]
26. Vascular complications with a plug-based vascular closure device after transcatheter aortic valve replacement: Predictors and bail-outs.
van Wiechen MP; Kroon H; Hokken TW; Ooms JF; de Ronde-Tillmans MJ; Daemen J; de Jaegere PP; Van Mieghem NM
Catheter Cardiovasc Interv; 2021 Nov; 98(5):E737-E745. PubMed ID: 33533544
[TBL] [Abstract][Full Text] [Related]
27. Percutaneous axillary arteriotomy closure during transcatheter aortic valve replacement using the MANTA device.
De Palma R; Rück A; Settergren M; Saleh N
Catheter Cardiovasc Interv; 2018 Nov; 92(5):998-1001. PubMed ID: 29068128
[TBL] [Abstract][Full Text] [Related]
28. Early Outcomes After Percutaneous Closure of Access Site in Transfemoral Transcatheter Valve Implantation Using the Novel Vascular Closure Device Collagen Plug-Based MANTA.
Gheorghe L; Brouwer J; Mathijssen H; Nijenhuis VJ; Rensing BJ; Swaans MJ; Chan Pin Yin DR; Heijmen RH; De Kroon T; Sonker U; Van der Heyden JA; Ten Berg JM
Am J Cardiol; 2019 Oct; 124(8):1265-1271. PubMed ID: 31443900
[TBL] [Abstract][Full Text] [Related]
29. Comparative data of single versus double proglide vascular preclose technique after percutaneous transfemoral transcatheter aortic valve implantation from the optimized catheter valvular intervention (OCEAN-TAVI) japanese multicenter registry.
Kodama A; Yamamoto M; Shimura T; Kagase A; Koyama Y; Tada N; Takagi K; Araki M; Yamanaka F; Shirai S; Watanabe Y; Hayashida K
Catheter Cardiovasc Interv; 2017 Sep; 90(3):E55-E62. PubMed ID: 27785881
[TBL] [Abstract][Full Text] [Related]
30. Frequency, Impact, and Predictors of Access Complications With Plug-Based Large-Bore Arteriotomy Closure - A Patient-Level Meta-Analysis.
Nuis RJ; Wood D; Kroon H; van Wiechen M; Bigelow D; Buller C; Daemen J; de Jaegere P; Krajcer Z; Webb J; Van Mieghem N
Cardiovasc Revasc Med; 2022 Jan; 34():69-74. PubMed ID: 33612412
[TBL] [Abstract][Full Text] [Related]
31. Clinical efficacy and safety of the PRO-glide device as a sUture-mediated ClosurE in Thoracic EndoVascular Aortic Repair in patients with previous groin intervention (from the PRODUCE-TEVAR Trial).
Çelik Ö; Şahin AA; Güner A; Demir AR; Uzun N; Ertürk M
Vascular; 2021 Apr; 29(2):237-243. PubMed ID: 32829695
[TBL] [Abstract][Full Text] [Related]
32. A multicenter, randomized, controlled trial of totally percutaneous access versus open femoral exposure for endovascular aortic aneurysm repair (the PEVAR trial).
Nelson PR; Kracjer Z; Kansal N; Rao V; Bianchi C; Hashemi H; Jones P; Bacharach JM
J Vasc Surg; 2014 May; 59(5):1181-93. PubMed ID: 24440678
[TBL] [Abstract][Full Text] [Related]
33. Outcomes of routine use of percutaneous access with large-bore introducer sheaths (>21F outer diameter) during endovascular aneurysm repair.
Melloni A; Grandi A; Spelta S; Salvati S; Loschi D; Lembo R; Melissano G; Chiesa R; Bertoglio L
J Vasc Surg; 2021 Jan; 73(1):81-91. PubMed ID: 32442603
[TBL] [Abstract][Full Text] [Related]
34. Percutaneous Axillary Artery Access in Complex Endovascular Aortic Repair.
Meertens M; Laturnus J; Ling A; Atkinson N; Mees B; Wagner T
J Vasc Interv Radiol; 2019 Jun; 30(6):830-835. PubMed ID: 31031090
[TBL] [Abstract][Full Text] [Related]
35. Percutaneous nitinol-based vascular closure device for large bore arterial access hemostasis: Results of a prospective multicenter study.
Barbash IM; Kornowski R; Berkovitch A; Assali A; Erlebach M; Guetta V; Vaknin Assa H; Lange R; Segev A; Ruge H
Catheter Cardiovasc Interv; 2020 Aug; 96(2):473-478. PubMed ID: 31912994
[TBL] [Abstract][Full Text] [Related]
36. Suture- or Plug-Based Large-Bore Arteriotomy Closure: A Pilot Randomized Controlled Trial.
van Wiechen MP; Tchétché D; Ooms JF; Hokken TW; Kroon H; Ziviello F; Ghattas A; Siddiqui S; Laperche C; Spitzer E; Daemen J; de Jaegere PP; Dumonteil N; Van Mieghem NM
JACC Cardiovasc Interv; 2021 Jan; 14(2):149-157. PubMed ID: 33358648
[TBL] [Abstract][Full Text] [Related]
37. First Experiences with MANTA Vascular Closure Device in Minimally Invasive Valve Surgery.
Ahmad AE; Salamate S; Amer M; Sirat S; Monsefi N; Bakhtiary F
Thorac Cardiovasc Surg; 2021 Aug; 69(5):455-460. PubMed ID: 33225434
[TBL] [Abstract][Full Text] [Related]
38. The ARAHKEY technique: A novel method for the management of access site bleeding during percutaneous transfemoral transcatheter aortic valve replacement.
Honda Y; Araki M; Yamawaki M; Hirano K; Kobayashi N; Sakamoto Y; Mori S; Tsutsumi M; Makino K; Ito Y
Catheter Cardiovasc Interv; 2020 Sep; 96(3):E355-E359. PubMed ID: 31815366
[TBL] [Abstract][Full Text] [Related]
39. Percutaneous endovascular abdominal aortic aneurysm repair: methods and initial outcomes from the first prospective, multicenter trial.
Krajcer Z; Nelson P; Bianchi C; Rao V; Morasch M; Bacharach J
J Cardiovasc Surg (Torino); 2011 Oct; 52(5):651-9. PubMed ID: 21796092
[TBL] [Abstract][Full Text] [Related]
40. Prophylactic Retrograde Distal Common Femoral Access as a Bail-out Strategy in Patients with Increased Risk for Femoral Access Complication During Transfemoral Aortic Valve Replacement.
Sanghvi K; Swarup S; Burns P; Kovach R; Ross R; Soussa T
Cardiovasc Revasc Med; 2020 Apr; 21(4):481-485. PubMed ID: 31375463
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]