1. Evaluation of a 3D surface imaging system for deep inspiration breath-hold patient positioning and intra-fraction monitoring.
Hamming VC; Visser C; Batin E; McDermott LN; Busz DM; Both S; Langendijk JA; Sijtsema NM
Radiat Oncol; 2019 Jul; 14(1):125. PubMed ID: 31296245
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of surface image guidance and Deep inspiration Breath Hold technique for breast treatments with Halcyon.
Crop F; Laffarguette J; Achag I; Pasquier D; Mirabel X; Cayez R; Lacornerie T
Phys Med; 2023 Apr; 108():102564. PubMed ID: 36989980
[TBL] [Abstract][Full Text] [Related]
3. Dose coverage and breath-hold analysis of breast cancer patients treated with surface-guided radiotherapy.
Dekker J; Essers M; Verheij M; Kusters M; de Kruijf W
Radiat Oncol; 2023 Apr; 18(1):72. PubMed ID: 37081477
[TBL] [Abstract][Full Text] [Related]
4. Accuracy evaluation of a 3-dimensional surface imaging system for guidance in deep-inspiration breath-hold radiation therapy.
Alderliesten T; Sonke JJ; Betgen A; Honnef J; van Vliet-Vroegindeweij C; Remeijer P
Int J Radiat Oncol Biol Phys; 2013 Feb; 85(2):536-42. PubMed ID: 22652107
[TBL] [Abstract][Full Text] [Related]
5. Estimation of heart-position variability in 3D-surface-image-guided deep-inspiration breath-hold radiation therapy for left-sided breast cancer.
Alderliesten T; Betgen A; Elkhuizen PH; van Vliet-Vroegindeweij C; Remeijer P
Radiother Oncol; 2013 Dec; 109(3):442-7. PubMed ID: 24161569
[TBL] [Abstract][Full Text] [Related]
6. Accuracy and potential improvements of surface-guided breast cancer radiotherapy in deep inspiration breath-hold with daily image-guidance.
Nankali S; Hansen R; Worm E; Yates ES; Thomsen MS; Offersen B; Poulsen PR
Phys Med Biol; 2022 Sep; 67(19):. PubMed ID: 36084626
[No Abstract] [Full Text] [Related]
7. Assessment of set-up variability during deep inspiration breath hold radiotherapy for breast cancer patients by 3D-surface imaging.
Betgen A; Alderliesten T; Sonke JJ; van Vliet-Vroegindeweij C; Bartelink H; Remeijer P
Radiother Oncol; 2013 Feb; 106(2):225-30. PubMed ID: 23414819
[TBL] [Abstract][Full Text] [Related]
8. AlignRT
Laaksomaa M; Sarudis S; Rossi M; Lehtonen T; Pehkonen J; Remes J; Luukkanen H; Skyttä T; Kapanen M
J Appl Clin Med Phys; 2019 Mar; 20(3):97-104. PubMed ID: 30861276
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of setup and intrafraction motion for surface guided whole-breast cancer radiotherapy.
Hattel SH; Andersen PA; Wahlstedt IH; Damkjaer S; Saini A; Thomsen JB
J Appl Clin Med Phys; 2019 Jun; 20(6):39-44. PubMed ID: 31187538
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of image-guided and surface-guided radiotherapy for breast cancer patients treated in deep inspiration breath-hold: A single institution experience.
Penninkhof J; Fremeijer K; Offereins-van Harten K; van Wanrooij C; Quint S; Kunnen B; Hoffmans-Holtzer N; Swaak A; Baaijens M; Dirkx M
Tech Innov Patient Support Radiat Oncol; 2022 Mar; 21():51-57. PubMed ID: 35243045
[TBL] [Abstract][Full Text] [Related]
11. Interfraction positional variation in pancreatic tumors using daily breath-hold cone-beam computed tomography with visual feedback.
Nakamura M; Akimoto M; Ono T; Nakamura A; Yano S; Nakata M; Itasaka S; Mizowaki T; Shibuya K; Hiraoka M
J Appl Clin Med Phys; 2015 Mar; 16(2):5123. PubMed ID: 26103180
[TBL] [Abstract][Full Text] [Related]
12. A voluntary breath-hold treatment technique for the left breast with unfavorable cardiac anatomy using surface imaging.
Gierga DP; Turcotte JC; Sharp GC; Sedlacek DE; Cotter CR; Taghian AG
Int J Radiat Oncol Biol Phys; 2012 Dec; 84(5):e663-8. PubMed ID: 22975605
[TBL] [Abstract][Full Text] [Related]
13. Assessment of the use of different imaging and delivery techniques for cranial treatments on the Halcyon linac.
Flores-Martinez E; Cerviño LI; Pawlicki T; Kim GY
J Appl Clin Med Phys; 2020 Jan; 21(1):53-61. PubMed ID: 31738473
[TBL] [Abstract][Full Text] [Related]
14. Optimal fractionation and timing of weekly cone-beam CT in daily surface-guided radiotherapy for breast cancer.
Peng H; Yang H; Lei J; Dai X; Cao P; Jin F; Luo H
Radiat Oncol; 2023 Jul; 18(1):112. PubMed ID: 37408037
[TBL] [Abstract][Full Text] [Related]
15. Patient setup accuracy in DIBH radiotherapy of breast cancer with lymph node inclusion using surface tracking and image guidance.
Rossi M; Laaksomaa M; Aula A
Med Dosim; 2022 Summer; 47(2):146-150. PubMed ID: 35039223
[TBL] [Abstract][Full Text] [Related]
16. Accuracy of surface-guided patient setup for conventional radiotherapy of brain and nasopharynx cancer.
Lee SK; Huang S; Zhang L; Ballangrud AM; Aristophanous M; Cervino Arriba LI; Li G
J Appl Clin Med Phys; 2021 May; 22(5):48-57. PubMed ID: 33792186
[TBL] [Abstract][Full Text] [Related]
17. Surface guided frameless positioning for lung stereotactic body radiation therapy.
Sarudis S; Karlsson A; Bäck A
J Appl Clin Med Phys; 2021 Sep; 22(9):215-226. PubMed ID: 34406710
[TBL] [Abstract][Full Text] [Related]
18. Use of surface-guided radiation therapy in combination with IGRT for setup and intrafraction motion monitoring during stereotactic body radiation therapy treatments of the lung and abdomen.
Heinzerling JH; Hampton CJ; Robinson M; Bright M; Moeller BJ; Ruiz J; Prabhu R; Burri SH; Foster RD
J Appl Clin Med Phys; 2020 May; 21(5):48-55. PubMed ID: 32196944
[TBL] [Abstract][Full Text] [Related]
19. Review of clinical applications and challenges with surface-guided radiation therapy.
Bellala R; Kuppusamy A; Bellala VM; Tyagi T; Manoharan S; Gangarapu G; Bellala R
J Cancer Res Ther; 2023; 19(5):1160-1169. PubMed ID: 37787279
[TBL] [Abstract][Full Text] [Related]
20. Prerequisites for the clinical implementation of a markerless SGRT-only workflow for the treatment of breast cancer patients.
Sauer TO; Ott OJ; Lahmer G; Fietkau R; Bert C
Strahlenther Onkol; 2023 Jan; 199(1):22-29. PubMed ID: 35788694
[TBL] [Abstract][Full Text] [Related]