These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

205 related articles for article (PubMed ID: 31298551)

  • 1. RAPID-CPU: a prospective study on implementation of the ESC 0/1-hour algorithm and safety of discharge after rule-out of myocardial infarction.
    Stoyanov KM; Hund H; Biener M; Gandowitz J; Riedle C; Löhr J; Mueller-Hennessen M; Vafaie M; Katus HA; Giannitsis E
    Eur Heart J Acute Cardiovasc Care; 2020 Feb; 9(1):39-51. PubMed ID: 31298551
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Randomized Trial of a 1-Hour Troponin T Protocol in Suspected Acute Coronary Syndromes: The Rapid Assessment of Possible Acute Coronary Syndrome in the Emergency Department With High-Sensitivity Troponin T Study (RAPID-TnT).
    Chew DP; Lambrakis K; Blyth A; Seshadri A; Edmonds MJR; Briffa T; Cullen LA; Quinn S; Karnon J; Chuang A; Nelson AJ; Wright D; Horsfall M; Morton E; French JK; Papendick C
    Circulation; 2019 Nov; 140(19):1543-1556. PubMed ID: 31478763
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Direct Comparison of 4 Very Early Rule-Out Strategies for Acute Myocardial Infarction Using High-Sensitivity Cardiac Troponin I.
    Boeddinghaus J; Nestelberger T; Twerenbold R; Wildi K; Badertscher P; Cupa J; Bürge T; Mächler P; Corbière S; Grimm K; Giménez MR; Puelacher C; Shrestha S; Flores Widmer D; Fuhrmann J; Hillinger P; Sabti Z; Honegger U; Schaerli N; Kozhuharov N; Rentsch K; Miró Ò; López B; Martin-Sanchez FJ; Rodriguez-Adrada E; Morawiec B; Kawecki D; Ganovská E; Parenica J; Lohrmann J; Kloos W; Buser A; Geigy N; Keller DI; Osswald S; Reichlin T; Mueller C
    Circulation; 2017 Apr; 135(17):1597-1611. PubMed ID: 28283497
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-Sensitivity Cardiac Troponin I and Clinical Risk Scores in Patients With Suspected Acute Coronary Syndrome.
    Chapman AR; Hesse K; Andrews J; Lee KK; Anand A; Shah ASV; Sandeman D; Ferry AV; Jameson J; Piya S; Stewart S; Marshall L; Strachan FE; Gray A; Newby DE; Mills NL
    Circulation; 2018 Oct; 138(16):1654-1665. PubMed ID: 30354460
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance of the European Society of Cardiology 0/1-Hour Algorithm With High-Sensitivity Cardiac Troponin T Among Patients With Known Coronary Artery Disease.
    Ashburn NP; Snavely AC; O'Neill JC; Allen BR; Christenson RH; Madsen T; Massoomi MR; McCord JK; Mumma BE; Nowak R; Stopyra JP; In't Veld MH; Wilkerson RG; Mahler SA
    JAMA Cardiol; 2023 Apr; 8(4):347-356. PubMed ID: 36857071
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cost-effectiveness of a rule-out algorithm of acute myocardial infarction in low-risk patients: emergency primary care versus hospital setting.
    Johannessen TR; Halvorsen S; Atar D; Munkhaugen J; Nore AK; Wisløff T; Vallersnes OM
    BMC Health Serv Res; 2022 Oct; 22(1):1274. PubMed ID: 36271364
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A single centre prospective cohort study addressing the effect of a rule-in/rule-out troponin algorithm on routine clinical practice.
    Marjot J; Kaier TE; Henderson K; Hunter L; Marber MS; Perera D
    Eur Heart J Acute Cardiovasc Care; 2019 Aug; 8(5):404-411. PubMed ID: 29199434
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multicentre cross-sectional observational registry to monitor the safety of early discharge after rule-out of acute myocardial infarction by copeptin and troponin: the Pro-Core registry.
    Giannitsis E; Clifford P; Slagman A; Ruedelstein R; Liebetrau C; Hamm C; Honnart D; Huber K; Vollert JO; Simonelli C; Schröder M; Wiemer JC; Mueller-Hennessen M; Schroer H; Kastner K; Möckel M
    BMJ Open; 2019 Jul; 9(7):e028311. PubMed ID: 31340965
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multicenter Evaluation of a 0-Hour/1-Hour Algorithm in the Diagnosis of Myocardial Infarction With High-Sensitivity Cardiac Troponin T.
    Mueller C; Giannitsis E; Christ M; Ordóñez-Llanos J; deFilippi C; McCord J; Body R; Panteghini M; Jernberg T; Plebani M; Verschuren F; French J; Christenson R; Weiser S; Bendig G; Dilba P; Lindahl B;
    Ann Emerg Med; 2016 Jul; 68(1):76-87.e4. PubMed ID: 26794254
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A randomized trial of a 1-hour troponin T protocol in suspected acute coronary syndromes: Design of the Rapid Assessment of Possible ACS In the emergency Department with high sensitivity Troponin T (RAPID-TnT) study.
    Papendick C; Blyth A; Seshadri A; Edmonds MJR; Briffa T; Cullen L; Quinn S; Karnon J; Chuang A; Nelson AJ; Horsfall M; Morton E; Chew DP
    Am Heart J; 2017 Aug; 190():25-33. PubMed ID: 28760210
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pre-hospital One-Hour Troponin in a Low-Prevalence Population of Acute Coronary Syndrome: OUT-ACS study.
    Johannessen TR; Vallersnes OM; Halvorsen S; Larstorp ACK; Mdala I; Atar D
    Open Heart; 2020 Jul; 7(2):. PubMed ID: 32719074
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay.
    Reichlin T; Twerenbold R; Wildi K; Gimenez MR; Bergsma N; Haaf P; Druey S; Puelacher C; Moehring B; Freese M; Stelzig C; Krivoshei L; Hillinger P; Jäger C; Herrmann T; Kreutzinger P; Radosavac M; Weidmann ZM; Pershyna K; Honegger U; Wagener M; Vuillomenet T; Campodarve I; Bingisser R; Miró Ò; Rentsch K; Bassetti S; Osswald S; Mueller C
    CMAJ; 2015 May; 187(8):E243-E252. PubMed ID: 25869867
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The HEART score in the era of the European Society of Cardiology 0/1-hour algorithm.
    Cortés M; Haseeb S; Lambardi F; Arbucci R; Ariznavarreta P; Resi S; Vergara JM; Katib C; Campos R; Trivi M; Costabel JP
    Eur Heart J Acute Cardiovasc Care; 2020 Feb; 9(1):30-38. PubMed ID: 31657616
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 0/1-Hour Triage Algorithm for Myocardial Infarction in Patients With Renal Dysfunction.
    Twerenbold R; Badertscher P; Boeddinghaus J; Nestelberger T; Wildi K; Puelacher C; Sabti Z; Rubini Gimenez M; Tschirky S; du Fay de Lavallaz J; Kozhuharov N; Sazgary L; Mueller D; Breidthardt T; Strebel I; Flores Widmer D; Shrestha S; Miró Ò; Martín-Sánchez FJ; Morawiec B; Parenica J; Geigy N; Keller DI; Rentsch K; von Eckardstein A; Osswald S; Reichlin T; Mueller C
    Circulation; 2018 Jan; 137(5):436-451. PubMed ID: 29101287
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A direct comparison of decision rules for early discharge of suspected acute coronary syndromes in the era of high sensitivity troponin.
    Chew PG; Frost F; Mullen L; Fisher M; Zadeh H; Grainger R; Albouaini K; Dodd J; Patel B; Velavan P; Kunadian B; Rawat A; Obafemi T; Tong S; Jones J; Khand A
    Eur Heart J Acute Cardiovasc Care; 2019 Aug; 8(5):421-431. PubMed ID: 29480016
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative Evaluation of 2-Hour Rapid Diagnostic Algorithms for Acute Myocardial Infarction Using High-Sensitivity Cardiac Troponin T.
    McRae AD; Innes G; Graham M; Lang E; Andruchow JE; Yang H; Ji Y; Vatanpour S; Southern DA; Wang D; Seiden-Long I; DeKoning L; Kavsak P
    Can J Cardiol; 2017 Aug; 33(8):1006-1012. PubMed ID: 28669701
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prognostic Utility of a Modified HEART Score in Chest Pain Patients in the Emergency Department.
    McCord J; Cabrera R; Lindahl B; Giannitsis E; Evans K; Nowak R; Frisoli T; Body R; Christ M; deFilippi CR; Christenson RH; Jacobsen G; Alquezar A; Panteghini M; Melki D; Plebani M; Verschuren F; French J; Bendig G; Weiser S; Mueller C;
    Circ Cardiovasc Qual Outcomes; 2017 Feb; 10(2):. PubMed ID: 28167641
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of the Efficacy and Safety of Early Rule-Out Pathways for Acute Myocardial Infarction.
    Chapman AR; Anand A; Boeddinghaus J; Ferry AV; Sandeman D; Adamson PD; Andrews J; Tan S; Cheng SF; D'Souza M; Orme K; Strachan FE; Nestelberger T; Twerenbold R; Badertscher P; Reichlin T; Gray A; Shah ASV; Mueller C; Newby DE; Mills NL
    Circulation; 2017 Apr; 135(17):1586-1596. PubMed ID: 28034899
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prospective comparative evaluation of the European Society of Cardiology (ESC) 1-hour and a 2-hour rapid diagnostic algorithm for myocardial infarction using high-sensitivity troponin-T.
    Andruchow JE; Boyne T; Seiden-Long I; Wang D; Vatanpour S; Innes G; McRae AD
    CJEM; 2020 Sep; 22(5):712-720. PubMed ID: 32624061
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Identifying Patients Suitable for Discharge After a Single-Presentation High-Sensitivity Troponin Result: A Comparison of Five Established Risk Scores and Two High-Sensitivity Assays.
    Carlton EW; Khattab A; Greaves K
    Ann Emerg Med; 2015 Dec; 66(6):635-645.e1. PubMed ID: 26260100
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.