BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 31300623)

  • 1. Electronics method to advance the coincidence time resolution with bismuth germanate.
    Cates JW; Levin CS
    Phys Med Biol; 2019 Sep; 64(17):175016. PubMed ID: 31300623
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental time resolution limits of modern SiPMs and TOF-PET detectors exploring different scintillators and Cherenkov emission.
    Gundacker S; Martinez Turtos R; Kratochwil N; Pots RH; Paganoni M; Lecoq P; Auffray E
    Phys Med Biol; 2020 Jan; 65(2):025001. PubMed ID: 31851947
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-frequency SiPM readout advances measured coincidence time resolution limits in TOF-PET.
    Gundacker S; Turtos RM; Auffray E; Paganoni M; Lecoq P
    Phys Med Biol; 2019 Feb; 64(5):055012. PubMed ID: 30630146
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On timing-optimized SiPMs for Cherenkov detection to boost low cost time-of-flight PET.
    Gundacker S; Borghi G; Cherry SR; Gola A; Lee D; Merzi S; Penna M; Schulz V; Kwon SI
    Phys Med Biol; 2023 Aug; 68(16):. PubMed ID: 37467766
    [No Abstract]   [Full Text] [Related]  

  • 5. Bismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET.
    Kwon SI; Gola A; Ferri A; Piemonte C; Cherry SR
    Phys Med Biol; 2016 Sep; 61(18):L38-L47. PubMed ID: 27589153
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved single photon time resolution for analog SiPMs with front end readout that reduces influence of electronic noise.
    Cates JW; Gundacker S; Auffray E; Lecoq P; Levin CS
    Phys Med Biol; 2018 Sep; 63(18):185022. PubMed ID: 30129562
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pushing Cherenkov PET with BGO via coincidence time resolution classification and correction.
    Kratochwil N; Gundacker S; Lecoq P; Auffray E
    Phys Med Biol; 2020 Jun; 65(11):115004. PubMed ID: 32268304
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a clinical TOF-PET detector design that achieves ⩽100 ps coincidence time resolution.
    Cates JW; Levin CS
    Phys Med Biol; 2018 Jun; 63(11):115011. PubMed ID: 29762136
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET.
    Cates JW; Choong WS
    Phys Med Biol; 2022 Sep; 67(19):. PubMed ID: 35961297
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 16-channel SiPM high-frequency readout with time-over-threshold discrimination for ultrafast time-of-flight applications.
    Nadig V; Hornisch M; Oehm J; Herweg K; Schulz V; Gundacker S
    EJNMMI Phys; 2023 Dec; 10(1):76. PubMed ID: 38044383
    [TBL] [Abstract][Full Text] [Related]  

  • 11. BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET.
    Brunner SE; Schaart DR
    Phys Med Biol; 2017 Jun; 62(11):4421-4439. PubMed ID: 28358722
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET.
    Cates JW; Choong WS; Brubaker E
    Phys Med Biol; 2024 Feb; 69(4):. PubMed ID: 38252971
    [No Abstract]   [Full Text] [Related]  

  • 13. Colored reflectors to improve coincidence timing resolution of BGO-based time-of-flight PET detectors.
    Lee D; Cherry SR; Kwon SI
    Phys Med Biol; 2023 Sep; 68(18):. PubMed ID: 37579768
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Highly multiplexed signal readout for a time-of-flight positron emission tomography detector based on silicon photomultipliers.
    Cates JW; Bieniosek MF; Levin CS
    J Med Imaging (Bellingham); 2017 Jan; 4(1):011012. PubMed ID: 28382312
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Timing advances of commercial divalent-ion co-doped LYSO:Ce and SiPMs in sub-100 ps time-of-flight positron emission tomography.
    Nadig V; Herweg K; Chou MMC; Lin JWC; Chin E; Li CA; Schulz V; Gundacker S
    Phys Med Biol; 2023 Mar; 68(7):. PubMed ID: 36808914
    [No Abstract]   [Full Text] [Related]  

  • 16. Performance evaluation of the FastIC readout ASIC with emphasis on Cherenkov emission in TOF-PET.
    Piller M; Castilla AM; Terragni G; Alozy J; Auffray E; Ballabriga R; Campbell M; Deutschmann B; Gascon D; Gola A; Merzi S; Michalowska-Forsyth A; Penna M; Gómez S; Kratochwil N
    Phys Med Biol; 2024 May; 69(11):. PubMed ID: 38657637
    [No Abstract]   [Full Text] [Related]  

  • 17. Development of capacitive multiplexing circuit for SiPM-based time-of-flight (TOF) PET detector.
    Choe HJ; Choi Y; Hu W; Yan J; Ho Jung J
    Phys Med Biol; 2017 Apr; 62(7):N120-N133. PubMed ID: 28263947
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Achieving fast timing performance with multiplexed SiPMs.
    Bieniosek MF; Cates JW; Levin CS
    Phys Med Biol; 2016 Apr; 61(7):2879-92. PubMed ID: 26987898
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Towards a metamaterial approach for fast timing in PET: experimental proof-of-concept.
    Turtos RM; Gundacker S; Auffray E; Lecoq P
    Phys Med Biol; 2019 Sep; 64(18):185018. PubMed ID: 30978716
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pushing the limit of BGO-based dual-ended Cherenkov PET detectors through photon transit time correction.
    Yi M; Ko GB; Lee JS
    Phys Med Biol; 2024 Jan; 69(2):. PubMed ID: 38091614
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 10.