BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 31302871)

  • 21. Photon beams for radiosurgery produced by laser Compton backscattering from relativistic electrons.
    Girolami B; Larsson B; Preger M; Schaerf C; Stepanek J
    Phys Med Biol; 1996 Sep; 41(9):1581-96. PubMed ID: 8884899
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Emission of fluorescent x-radiation from non-lead based shielding materials of protective clothing: a radiobiological problem?
    Schmid E; Panzer W; Schlattl H; Eder H
    J Radiol Prot; 2012 Sep; 32(3):N129-39. PubMed ID: 22809876
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Shielding performance of multi-metal nanoparticle composites for diagnostic radiology: an MCNPX and Geant4 study.
    Asadpour N; Malekzadeh R; Rajabpour S; Refahi S; Mehnati P; Shanei A
    Radiol Phys Technol; 2023 Mar; 16(1):57-68. PubMed ID: 36562940
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Radiation shielding assessment for interventional radiology personnel: Geant4 dosimetry of lead-free compositions.
    Moradi F; Jalili M; Saraee KRE; Abdi MR; Rashid HAA
    Biomed Phys Eng Express; 2024 Feb; 10(2):. PubMed ID: 38320327
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Assessment of patient dose reduction by bismuth shielding in CT using measurements, GEANT4 and MCNPX simulations.
    Mendes M; Costa F; Figueira C; Madeira P; Teles P; Vaz P
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):175-81. PubMed ID: 25813483
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of the contribution of capture gamma rays, x-ray leakage, and scatter to the photon dose at the maze door for a high energy medical electron accelerator using a Monte Carlo particle transport code.
    McGinley PH; Dhaba'an AH; Reft CS
    Med Phys; 2000 Jan; 27(1):225-30. PubMed ID: 10659761
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Physical characterization of single convergent beam device for teletherapy: theoretical and Monte Carlo approach.
    Figueroa RG; Valente M
    Phys Med Biol; 2015 Sep; 60(18):7191-206. PubMed ID: 26348025
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Mass attenuation coefficients of clear-Pb for photons from 125I, 103Pd, 99mTc, 192Ir, 137Cs and 60Co.
    Rivard MJ; Waid DS; Wierzbicki JG
    Health Phys; 1999 Nov; 77(5):571-8. PubMed ID: 10524511
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Shielding evaluation for solar particle events using MCNPX, PHITS and OLTARIS codes.
    Aghara SK; Sriprisan SI; Singleterry RC; Sato T
    Life Sci Space Res (Amst); 2015 Jan; 4():79-91. PubMed ID: 26177623
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Overestimations in zero frequency DQE of x-ray imaging converters assessed by Monte Carlo techniques based on the study of energy impartation events.
    Liaparinos PF; Kandarakis IS
    Med Phys; 2011 Jul; 38(7):4440-50. PubMed ID: 21859045
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Monte Carlo simulation of diagnostic x-ray scatter.
    Papin PJ; Rielly PS
    Med Phys; 1988; 15(6):909-14. PubMed ID: 3237150
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of gadolinium nanoparticles and molecular contrast agents for radiation therapy-enhancement.
    Delorme R; Taupin F; Flaender M; Ravanat JL; Champion C; Agelou M; Elleaume H
    Med Phys; 2017 Nov; 44(11):5949-5960. PubMed ID: 28886212
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Radiation shielding evaluation of the BNCT treatment room at THOR: a TORT-coupled MCNP Monte Carlo simulation study.
    Chen AY; Liu YW; Sheu RJ
    Appl Radiat Isot; 2008 Jan; 66(1):28-38. PubMed ID: 17825572
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes.
    Al-Affan IA; Hugtenburg RP; Bari DS; Al-Saleh WM; Piliero M; Evans S; Al-Hasan M; Al-Zughul B; Al-Kharouf S; Ghaith A
    Med Phys; 2015 Feb; 42(2):606-14. PubMed ID: 25771559
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Scattered radiation in scanning slot mammography.
    Jing Z; Huda W; Walker JK
    Med Phys; 1998 Jul; 25(7 Pt 1):1111-7. PubMed ID: 9682196
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Monte Carlo studies on photon interactions in radiobiological experiments.
    Shahmohammadi Beni M; Krstic D; Nikezic D; Yu KN
    PLoS One; 2018; 13(3):e0193575. PubMed ID: 29561871
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Monte Carlo calculation of dose rate conversion factors for external exposure to photon emitters in soil.
    Clouvas A; Xanthos S; Antonopoulos-Domis M; Silva J
    Health Phys; 2000 Mar; 78(3):295-302. PubMed ID: 10688452
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Analytic model of energy-absorption response functions in compound X-ray detector materials.
    Yun S; Kim HK; Youn H; Tanguay J; Cunningham IA
    IEEE Trans Med Imaging; 2013 Oct; 32(10):1819-28. PubMed ID: 23744671
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effects of shielding on pelvic and abdominal IORT dose distributions.
    Esposito A; Sakellaris T; Limede P; Costa F; Cunha LT; Dias AG; Lencart J; Sarmento S; Rosa CC
    Phys Med; 2016 Nov; 32(11):1397-1404. PubMed ID: 27780674
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Transmission of broad W/Rh and W/Al (target/filter) x-ray beams operated at 25-49 kVp through common shielding materials.
    Li X; Zhang D; Liu B
    Med Phys; 2012 Jul; 39(7):4132-8. PubMed ID: 22830746
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.