BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

427 related articles for article (PubMed ID: 31310033)

  • 21. Electrophysiologic and anatomic factors predictive of a need for touch-up radiofrequency application for complete pulmonary vein isolation: Comparison between hot balloon- and cryoballoon-based ablation.
    Wakamatsu Y; Nagashima K; Nakahara S; Iso K; Watanabe R; Arai M; Otsuka N; Yagyu S; Kurokawa S; Ohkubo K; Nakai T; Okumura Y
    J Cardiovasc Electrophysiol; 2019 Aug; 30(8):1261-1269. PubMed ID: 31111558
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: lessons from repeat ablation procedures.
    Ciconte G; Velagić V; Mugnai G; Saitoh Y; Irfan G; Hunuk B; Ströker E; Conte G; Sieira J; Di Giovanni G; Baltogiannis G; Brugada P; de Asmundis C; Chierchia GB
    Europace; 2016 Jan; 18(1):71-7. PubMed ID: 26445821
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Cryoballoon versus radiofrequency catheter ablation of paroxysmal atrial fibrillation: biomarkers of myocardial injury, recurrence rates, and pulmonary vein reconnection patterns.
    Kühne M; Suter Y; Altmann D; Ammann P; Schaer B; Osswald S; Sticherling C
    Heart Rhythm; 2010 Dec; 7(12):1770-6. PubMed ID: 20817019
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Supplemental Radiofrequency Ablation After Acutely Unsuccessful Cryoballoon Pulmonary Vein Isolation is Associated With Increased Risk of Recurrent Atrial Fibrillation.
    Huang HD; Pietrasik G; Abid QU; Sharma PS; Krishnan K; Larsen TR; Trohman RG
    J Am Heart Assoc; 2020 May; 9(10):e015979. PubMed ID: 32394797
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis.
    Aryana A; Singh SM; Mugnai G; de Asmundis C; Kowalski M; Pujara DK; Cohen AI; Singh SK; Fuenzalida CE; Prager N; Bowers MR; O'Neill PG; Brugada P; d'Avila A; Chierchia GB
    J Interv Card Electrophysiol; 2016 Dec; 47(3):341-348. PubMed ID: 27475949
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Cryoballoon versus radiofrequency for pulmonary vein re-isolation after a failed initial ablation procedure in patients with paroxysmal atrial fibrillation.
    Pokushalov E; Romanov A; Artyomenko S; Baranova V; Losik D; Bairamova S; Karaskov A; Mittal S; Steinberg JS
    J Cardiovasc Electrophysiol; 2013 Mar; 24(3):274-9. PubMed ID: 23210695
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cryoballoon versus radiofrequency ablation for paroxysmal atrial fibrillation in hemodialysis patients.
    Takamiya T; Nitta J; Inaba O; Sato A; Inamura Y; Kato N; Murata K; Ikenouchi T; Kono T; Nitta G; Matsumura Y; Takahashi Y; Goya M; Sasano T
    Heart Vessels; 2020 Dec; 35(12):1709-1716. PubMed ID: 32524235
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Quantitative Analysis of the Isolation Area During the Chronic Phase After a 28-mm Second-Generation Cryoballoon Ablation Demarcated by High-Resolution Electroanatomic Mapping.
    Miyazaki S; Taniguchi H; Hachiya H; Nakamura H; Takagi T; Iwasawa J; Hirao K; Iesaka Y
    Circ Arrhythm Electrophysiol; 2016 May; 9(5):e003879. PubMed ID: 27146418
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Differences in scar lesion formation between radiofrequency and cryoballoon in atrial fibrillation ablation: a comparison study using ultra-high-density mapping.
    Ruiz-Granell R; Ballesteros G; Andreu D; Erkiaga A; Ferrero-De-Loma-Osorio A; Ramos P; Martínez-Brotons A; Vives-Rodríguez E; Izquierdo-de-Francisco M; García-Bolao I
    Europace; 2019 Feb; 21(2):250-258. PubMed ID: 30321320
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The fourth cryoballoon generation with a shorter tip to facilitate real-time pulmonary vein potential recording: Feasibility and safety results.
    Straube F; Dorwarth U; Pongratz J; Brück B; Wankerl M; Hartl S; Hoffmann E
    J Cardiovasc Electrophysiol; 2019 Jun; 30(6):918-925. PubMed ID: 30907462
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Functional disconnection of arrhythmogenic pulmonary veins in patients with paroxysmal atrial fibrillation guided by combined electroanatomical (CARTO) and conventional mapping.
    Weiss C; Willems S; Risius T; Hoffmann M; Ventura R; Meinertz T
    J Interv Card Electrophysiol; 2002 Jul; 6(3):267-75. PubMed ID: 12154329
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Cryoballoon vs. radiofrequency ablation for paroxysmal atrial fibrillation: an updated meta-analysis of randomized and observational studies.
    Buiatti A; von Olshausen G; Barthel P; Schneider S; Luik A; Kaess B; Laugwitz KL; Hoppmann P
    Europace; 2017 Mar; 19(3):378-384. PubMed ID: 27702864
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Cryoballoon versus Radiofrequency Catheter Ablation in Atrial Fibrillation: A Meta-Analysis.
    Cardoso R; Mendirichaga R; Fernandes G; Healy C; Lambrakos LK; Viles-Gonzalez JF; Goldberger JJ; Mitrani RD
    J Cardiovasc Electrophysiol; 2016 Oct; 27(10):1151-1159. PubMed ID: 27422848
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Regular atrial tachycardias developing after cryoballoon pulmonary vein isolation: incidence, characteristics, and predictors.
    Mikhaylov EN; Bhagwandien R; Janse PA; Theuns DA; Szili-Torok T
    Europace; 2013 Dec; 15(12):1710-7. PubMed ID: 23689485
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Additional cryoapplications at the pulmonary vein antrum using a 28-mm second-generation cryoballoon: a pilot study of extra-pulmonary vein ablation.
    Miyazaki S; Kajiyama T; Watanabe T; Ichijo S; Iesaka Y
    Heart Vessels; 2018 Sep; 33(9):1052-1059. PubMed ID: 29464341
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Propensity-matched comparison of cryoballoon and radiofrequency ablation for atrial fibrillation in elderly patients.
    Ikenouchi T; Nitta J; Nitta G; Kato S; Iwasaki T; Murata K; Junji M; Hirao T; Kanoh M; Takamiya T; Kato N; Inamura Y; Negi K; Sato A; Yamato T; Matsumura Y; Takahashi Y; Goya M; Hirao K
    Heart Rhythm; 2019 Jun; 16(6):838-845. PubMed ID: 30576880
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Incidence of early pulmonary vein reconnections using different energy sources for pulmonary vein isolation: Multielectrode phased radiofrequency vs second-generation cryoballoon.
    Wieczorek M; Tajtaraghi S; Sassani K; Hoeltgen R
    J Cardiovasc Electrophysiol; 2019 Sep; 30(9):1428-1435. PubMed ID: 31111548
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Incidence of silent cerebral infarctions after catheter ablation of atrial fibrillation utilizing the second-generation cryoballoon.
    Nakamura T; Okishige K; Kanazawa T; Yamashita M; Kawaguchi N; Kato N; Aoyagi H; Yamauchi Y; Sasano T; Hirao K
    Europace; 2017 Oct; 19(10):1681-1688. PubMed ID: 27702854
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Differential gap location after radiofrequency versus cryoballoon pulmonary vein isolation: Insights from a randomized trial with protocol-mandated repeat procedure.
    Sørensen SK; Johannessen A; Worck R; Hansen ML; Ruwald MH; Hansen J
    J Cardiovasc Electrophysiol; 2023 Mar; 34(3):519-526. PubMed ID: 36640430
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Repeat procedures using the second-generation cryoballoon for recurrence of atrial fibrillation after initial ablation with conventional radiofrequency.
    De Regibus V; Iacopino S; Abugattas JP; Mugnai G; Moran D; Ströker E; Coutino HE; Takarada K; Choudhury R; Paparella G; Umbrain V; Brugada P; de Asmundis C; Chierchia GB
    J Interv Card Electrophysiol; 2017 Aug; 49(2):119-125. PubMed ID: 28315135
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 22.