188 related articles for article (PubMed ID: 31310389)
41. Mind the gap: Quantification of incomplete ablation patterns after pulmonary vein isolation using minimum path search.
Nuñez-Garcia M; Camara O; O'Neill MD; Razavi R; Chubb H; Butakoff C
Med Image Anal; 2019 Jan; 51():1-12. PubMed ID: 30347332
[TBL] [Abstract][Full Text] [Related]
42. Two-year clinical outcome after a single cryoballoon ablation procedure: A comparison of first- and second-generation cryoballoons.
Zhao A; Squara F; Marijon E; Thomas O
Arch Cardiovasc Dis; 2017 Oct; 110(10):543-549. PubMed ID: 28958871
[TBL] [Abstract][Full Text] [Related]
43. Recurrence of atrial fibrillation correlates with the extent of post-procedural late gadolinium enhancement: a pilot study.
Peters DC; Wylie JV; Hauser TH; Nezafat R; Han Y; Woo JJ; Taclas J; Kissinger KV; Goddu B; Josephson ME; Manning WJ
JACC Cardiovasc Imaging; 2009 Mar; 2(3):308-16. PubMed ID: 19356576
[TBL] [Abstract][Full Text] [Related]
44. Pressure-guided second-generation cryoballoon pulmonary vein isolation: Prospective comparison of the procedural and clinical outcomes with the conventional strategy.
Hasegawa K; Miyazaki S; Kaseno K; Hisazaki K; Amaya N; Miyahara K; Aiki T; Ishikawa E; Mukai M; Matsui A; Aoyama D; Shiomi Y; Tama N; Ikeda H; Fukuoka Y; Morishita T; Ishida K; Uzui H; Tada H
J Cardiovasc Electrophysiol; 2019 Oct; 30(10):1841-1847. PubMed ID: 31328311
[TBL] [Abstract][Full Text] [Related]
45. Vasovagal responses during cryoballoon pulmonary vein isolation in paroxysmal atrial fibrillation predict favorable mid-term outcomes.
Te ALD; Lo LW; Lin YJ; Chang SL; Hu YF; Chung FP; Tuan TC; Chao TF; Liao JN; Chang YT; Lin CY; Yamada S; Chang TY; Salim S; Hoang MQ; Huang TC; Chen SA
Int J Cardiol; 2018 May; 258():115-120. PubMed ID: 29467097
[TBL] [Abstract][Full Text] [Related]
46. Cryoballoon ablation versus radiofrequency ablation for atrial fibrillation.
Reissmann B; Metzner A; Kuck KH
Trends Cardiovasc Med; 2017 May; 27(4):271-277. PubMed ID: 28089202
[TBL] [Abstract][Full Text] [Related]
47. Characterization of conduction recovery after pulmonary vein isolation using the "single big cryoballoon" technique.
Fürnkranz A; Chun KR; Nuyens D; Metzner A; Köster I; Schmidt B; Ouyang F; Kuck KH
Heart Rhythm; 2010; 7(2):184-90. PubMed ID: 20129295
[TBL] [Abstract][Full Text] [Related]
48. Impact of Cryoballoon Freeze Duration on Long-Term Durability of Pulmonary Vein Isolation: ICE Re-Map Study.
Chen S; Schmidt B; Bordignon S; Perrotta L; Bologna F; Chun KRJ
JACC Clin Electrophysiol; 2019 May; 5(5):551-559. PubMed ID: 31122376
[TBL] [Abstract][Full Text] [Related]
49. Additional cryoapplications at the pulmonary vein antrum using a 28-mm second-generation cryoballoon: a pilot study of extra-pulmonary vein ablation.
Miyazaki S; Kajiyama T; Watanabe T; Ichijo S; Iesaka Y
Heart Vessels; 2018 Sep; 33(9):1052-1059. PubMed ID: 29464341
[TBL] [Abstract][Full Text] [Related]
50. Postprocedural LGE-CMR comparison of laser and radiofrequency ablation lesions after pulmonary vein isolation.
Figueras I Ventura RM; Mǎrgulescu AD; Benito EM; Alarcón F; Enomoto N; Prat-Gonzalez S; Perea RJ; Borràs R; Chipa F; Arbelo E; Tolosana JM; Brugada J; Berruezo A; Mont L
J Cardiovasc Electrophysiol; 2018 Aug; 29(8):1065-1072. PubMed ID: 29722466
[TBL] [Abstract][Full Text] [Related]
51. Sex-specific efficacy and safety of cryoballoon versus radiofrequency ablation for atrial fibrillation: A systematic review and meta-analysis.
du Fay de Lavallaz J; Clerc O; Pudenz C; Illigens B; Kühne M
J Cardiovasc Electrophysiol; 2019 Oct; 30(10):1819-1829. PubMed ID: 31310375
[TBL] [Abstract][Full Text] [Related]
52. Analysis of the anatomical features of pulmonary veins on pre-procedural cardiac CT images resulting in incomplete cryoballoon ablation for atrial fibrillation.
Matsumoto Y; Muraoka Y; Funama Y; Mito S; Masuda T; Sato T; Akita T; Awai K
J Cardiovasc Comput Tomogr; 2019; 13(2):118-127. PubMed ID: 30466810
[TBL] [Abstract][Full Text] [Related]
53. Repeat Ablation for Atrial Fibrillation Recurrence Post Cryoballoon or Radiofrequency Ablation in the FIRE AND ICE Trial.
Kuck KH; Albenque JP; Chun KJ; Fürnkranz A; Busch M; Elvan A; Schlüter M; Braegelmann KM; Kueffer FJ; Hemingway L; Arentz T; Tondo C; Brugada J;
Circ Arrhythm Electrophysiol; 2019 May; 12(6):e007247. PubMed ID: 31693319
[TBL] [Abstract][Full Text] [Related]
54. Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation.
Squara F; Zhao A; Marijon E; Latcu DG; Providencia R; Di Giovanni G; Jauvert G; Jourda F; Chierchia GB; De Asmundis C; Ciconte G; Alonso C; Grimard C; Boveda S; Cauchemez B; Saoudi N; Brugada P; Albenque JP; Thomas O
Europace; 2015 May; 17(5):718-24. PubMed ID: 25840289
[TBL] [Abstract][Full Text] [Related]
55. The predictive role of early recurrences of atrial arrhythmias after pulmonary vein cryoballoon ablation. Is blanking period an outdated concept? Insights from 12-month continuous cardiac monitoring.
Davtyan KV; Topchyan AH; Brutyan HA; Kalemberg EN; Kharlap MS; Simonyan GY; Kalemberg AA; Kuznetsova MV
BMC Cardiovasc Disord; 2021 Oct; 21(1):483. PubMed ID: 34620082
[TBL] [Abstract][Full Text] [Related]
56. Shortening of freezing cycles provides equal outcome to standard ablation procedure using second-generation 28 mm cryoballoon after 15-month follow-up.
Tebbenjohanns J; Höfer C; Bergmann L; Dedroogh M; Gaudin D; von Werder A; Rühmkorf K
Europace; 2016 Feb; 18(2):206-10. PubMed ID: 26071236
[TBL] [Abstract][Full Text] [Related]
57. Impact of an additional right pulmonary vein on second-generation cryoballoon ablation for atrial fibrillation: a propensity matched score study.
Takarada K; Ströker E; Abugattas JP; de Regibus V; Coutiño HE; Lusoc I; Capulzini L; Sieira J; Mugnai G; Salghetti F; Choudhury R; Iacopino S; de Asmundis C; Brugada P; Chierchia GB
J Interv Card Electrophysiol; 2019 Jan; 54(1):1-8. PubMed ID: 29679186
[TBL] [Abstract][Full Text] [Related]
58. Spontaneous and adenosine-induced pulmonary vein reconnection after cryoballoon ablation with the second-generation device.
Ciconte G; Chierchia GB; DE Asmundis C; Sieira J; Conte G; Juliá J; DI Giovanni G; Wauters K; Baltogiannis G; Saitoh Y; Mugnai G; Catanzariti D; Tondo C; Brugada P
J Cardiovasc Electrophysiol; 2014 Aug; 25(8):845-851. PubMed ID: 24678900
[TBL] [Abstract][Full Text] [Related]
59. High rate of durable pulmonary vein isolation after second-generation cryoballoon ablation: analysis of repeat procedures.
Bordignon S; Fürnkranz A; Perrotta L; Dugo D; Konstantinou A; Nowak B; Schulte-Hahn B; Schmidt B; Chun KR
Europace; 2015 May; 17(5):725-31. PubMed ID: 25618741
[TBL] [Abstract][Full Text] [Related]
60. Earliest pulmonary vein potential-guided cryoballoon ablation for atrial fibrillation.
Mizutani Y; Kanashiro M; Makino Y; Satake A; Suzuki W; Kurobe M; Mizutani K; Ichimiya H; Uchida Y; Watanabe J; Ichimiya S; Inden Y; Murohara T
Heart Vessels; 2020 Feb; 35(2):232-238. PubMed ID: 31297640
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]