These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

247 related articles for article (PubMed ID: 31311570)

  • 41. OPTY-LINE remote-controlled adjustable intramedullary device implantation in open-wedge high tibial osteotomy: A prospective proof-of-concept pilot and comparison with Tomofix fixed-plate device method.
    Jonker L; Fallahi F; Saraswathy JJ; Edge J; Dawson M
    J Orthop Surg (Hong Kong); 2019; 27(3):2309499019864721. PubMed ID: 31379259
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study.
    Spahn G; Wittig R
    J Orthop Sci; 2002; 7(6):683-7. PubMed ID: 12486473
    [TBL] [Abstract][Full Text] [Related]  

  • 43. The impact of plate length, fibula integrity and plate placement on tibial shaft fixation stability: a finite element study.
    Cao Y; Zhang Y; Huang L; Huang X
    J Orthop Surg Res; 2019 Feb; 14(1):52. PubMed ID: 30767784
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Hinge location and apical drill holes in opening wedge high tibial osteotomy: A finite element analysis.
    Boström A; Amin AK; Macpherson GJ; Pankaj P; Scott CEH
    J Orthop Res; 2021 Mar; 39(3):628-636. PubMed ID: 32352597
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Development and validation of a finite element model to simulate the opening of a medial opening wedge high tibial osteotomy.
    Carranza VA; Reeves J; Getgood A; Burkhart TA
    Comput Methods Biomech Biomed Engin; 2019 Mar; 22(4):442-449. PubMed ID: 30714405
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Stability of two angular stable locking plates for open wedge high tibial osteotomy (HTO): TomoFix™ versus LOQTEQ® HTO plate.
    Petersen W; Wall A; Paulin T; Park HU; Heymann L
    Arch Orthop Trauma Surg; 2014 Oct; 134(10):1437-42. PubMed ID: 25015791
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A customized fixation plate with novel structure designed by topological optimization for mandibular angle fracture based on finite element analysis.
    Liu YF; Fan YY; Jiang XF; Baur DA
    Biomed Eng Online; 2017 Nov; 16(1):131. PubMed ID: 29141673
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Reinforcement strategy for medial open-wedge high tibial osteotomy: a finite element evaluation of the additional opposite screw technique and bone grafts.
    Zhao XW; Fan ZR; Ma JX; Ma XL; Wang Y; Bai HH; Lu B; Sun L
    Comput Methods Programs Biomed; 2022 Jan; 213():106523. PubMed ID: 34808530
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Large correction in opening wedge high tibial osteotomy with resultant joint-line obliquity induces excessive shear stress on the articular cartilage.
    Nakayama H; Schröter S; Yamamoto C; Iseki T; Kanto R; Kurosaka K; Kambara S; Yoshiya S; Higa M
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1873-1878. PubMed ID: 28831525
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Primary stability of four different implants for opening wedge high tibial osteotomy.
    Agneskirchner JD; Freiling D; Hurschler C; Lobenhoffer P
    Knee Surg Sports Traumatol Arthrosc; 2006 Mar; 14(3):291-300. PubMed ID: 16284740
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Total knee arthroplasty after failed high tibial osteotomy: a systematic review of open versus closed wedge osteotomy.
    Han JH; Yang JH; Bhandare NN; Suh DW; Lee JS; Chang YS; Yeom JW; Nha KW
    Knee Surg Sports Traumatol Arthrosc; 2016 Aug; 24(8):2567-77. PubMed ID: 26423055
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Health-related quality of life and clinical outcomes following medial open wedge high tibial osteotomy: a prospective study.
    Ihle C; Ateschrang A; Grünwald L; Stöckle U; Saier T; Schröter S
    BMC Musculoskelet Disord; 2016 May; 17():215. PubMed ID: 27189005
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Comparison of Lateral Closing-Wedge Versus Medial Opening-Wedge High Tibial Osteotomy on Knee Joint Alignment and Kinematics in the ACL-Deficient Knee.
    Ranawat AS; Nwachukwu BU; Pearle AD; Zuiderbaan HA; Weeks KD; Khamaisy S
    Am J Sports Med; 2016 Dec; 44(12):3103-3110. PubMed ID: 27496910
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy.
    Diffo Kaze A; Maas S; Waldmann D; Zilian A; Dueck K; Pape D
    J Exp Orthop; 2015 Dec; 2(1):14. PubMed ID: 26914882
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Comparison of sagittal and frontal plane alignment after open- and closed-wedge osteotomy: a matched-pair analysis.
    Schaefer TK; Majewski M; Hirschmann MT; Friederich NF
    J Int Med Res; 2008; 36(5):1085-93. PubMed ID: 18831905
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Biomechanical comparison of two different locking plates for open wedge high tibial osteotomy.
    van Egmond N; Janssen D; Hannink G; Verdonschot N; van Kampen A
    J Orthop Sci; 2018 Jan; 23(1):105-111. PubMed ID: 29032860
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Use of simple algorithms to predict screw length facilitates navigation-controlled medial opening-wedge osteotomy using the TomoFix HTO system.
    Kim TK; Chang CB; Lee KH; Cho HJ; Je MS; Won HH; Kang YG
    Orthopedics; 2012 Oct; 35(10 Suppl):22-8. PubMed ID: 23026248
    [TBL] [Abstract][Full Text] [Related]  

  • 58. How plate positioning impacts the biomechanics of the open wedge tibial osteotomy; a finite element analysis.
    Blecha LD; Zambelli PY; Ramaniraka NA; Bourban PE; Månson JA; Pioletti DP
    Comput Methods Biomech Biomed Engin; 2005 Oct; 8(5):307-13. PubMed ID: 16298852
    [TBL] [Abstract][Full Text] [Related]  

  • 59. [Cartilage regeneration after high tibial osteotomy. Results of an arthroscopic study].
    Spahn G; Klinger HM; Harth P; Hofmann GO
    Z Orthop Unfall; 2012 Jun; 150(3):272-9. PubMed ID: 22729374
    [TBL] [Abstract][Full Text] [Related]  

  • 60. The stability of three commercially available implants used in medial opening wedge high tibial osteotomy.
    Dorsey WO; Miller BS; Tadje JP; Bryant CR
    J Knee Surg; 2006 Apr; 19(2):95-8. PubMed ID: 16642884
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.