These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

235 related articles for article (PubMed ID: 31315014)

  • 1. Minimally Invasive Plate Osteosynthesis (MIPO) technique for complex tibial shaft fracture.
    Choi S; Lee TJ; Kim S; Cho C; Shim S; Kang H
    Acta Orthop Belg; 2019 Jun; 85(2):224-233. PubMed ID: 31315014
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of intramedullary nailing and minimal invasive plate osteosynthesis in the treatment of simple intra-articular fractures of the distal tibia (AO-OTA type 43 C1-C2).
    Beytemür O; Barış A; Albay C; Yüksel S; Çağlar S; Alagöz E
    Acta Orthop Traumatol Turc; 2017 Jan; 51(1):12-16. PubMed ID: 27825761
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Minimally invasive plate osteosynthesis for open fractures of the proximal tibia.
    Kim JW; Oh CW; Jung WJ; Kim JS
    Clin Orthop Surg; 2012 Dec; 4(4):313-20. PubMed ID: 23205242
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical and radiological outcome of Gustilo type III open distal tibial and tibial shaft fractures after staged treatment with posterolateral minimally invasive plate osteosynthesis (MIPO) technique.
    He X; Hu C; Zhou K; Zhai Q; Wen W; Pan F
    Arch Orthop Trauma Surg; 2018 Aug; 138(8):1097-1102. PubMed ID: 29748878
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Minimally-invasive plate osteosynthesis in distal tibial fractures: Results and complications.
    Vidović D; Matejčić A; Ivica M; Jurišić D; Elabjer E; Bakota B
    Injury; 2015 Nov; 46 Suppl 6():S96-9. PubMed ID: 26584733
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Limited open reduction is better for simple- distal tibial shaft fractures than minimally invasive plate osteosynthesis.
    Li Q; Zeng BF; Luo CF; Song S; Zhang CQ; Kong WQ
    Genet Mol Res; 2014 Jul; 13(3):5361-8. PubMed ID: 25078592
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Minimally Invasive Plate Osteosynthesis Using Locking Plates for AO 43-Type Fractures: Lessons Learnt From a Prospective Study.
    Shukla R; Jain N; Jain RK; Patidar S; Kiyawat V
    Foot Ankle Spec; 2018 Jun; 11(3):236-241. PubMed ID: 28814102
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Minimally invasive plate osteosynthesis has equal safety to reamed intramedullary nails in treating Gustilo-Anderson type I, II and III-A open tibial shaft fractures.
    Galal S
    Injury; 2018 Apr; 49(4):866-870. PubMed ID: 29530513
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome.
    Kim JW; Oh CW; Oh JK; Kyung HS; Park KH; Kim HJ; Jung JW; Jung YS
    Injury; 2017 Jun; 48(6):1190-1193. PubMed ID: 28320508
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fracture gap and working length are important actionable factors affecting bone union after minimally invasive plate osteosynthesis for the treatment of simple diaphyseal or distal metaphyseal tibia fractures.
    Kim TH; Heo YM; Kim KK; Kang C; Kim TG; Lee GS; Shin WJ; Song JH
    Orthop Traumatol Surg Res; 2024 Apr; 110(2):103770. PubMed ID: 37979671
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Treatment of Fractures of the Distal Third of Tibia Diaphysis by MIPO Technique].
    Schwarz O; Majerníček M; Chomiak J
    Acta Chir Orthop Traumatol Cech; 2020; 87(2):114-119. PubMed ID: 32396512
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison between intramedullary nailing and minimally invasive plate osteosynthesis for tibial shaft fractures.
    Kang H; Rho JY; Song JK; Choi J; Kwon YS; Choi S
    Injury; 2021 Apr; 52(4):1011-1016. PubMed ID: 33563414
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Minimally invasive plate osteosynthesis with locking compression plate for distal diametaphyseal tibia fracture.
    Shrestha D; Acharya BM; Shrestha PM
    Kathmandu Univ Med J (KUMJ); 2011; 9(34):62-8. PubMed ID: 22610872
    [TBL] [Abstract][Full Text] [Related]  

  • 14. May minimally invasive plate osteosynthesis be an alternative to intramedullary nailing in selected spiral oblique and spiral wedge tibial shaft fractures?
    Katı YA; Öken ÖF; Yıldırım AÖ; Köse Ö; Ünal M
    Jt Dis Relat Surg; 2020; 31(3):494-501. PubMed ID: 32962581
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Prospective Randomized Study on Operative Treatment for Simple Distal Tibial Fractures-Minimally Invasive Plate Osteosynthesis Versus Minimal Open Reduction and Internal Fixation.
    Kim JW; Kim HU; Oh CW; Kim JW; Park KC
    J Orthop Trauma; 2018 Jan; 32(1):e19-e24. PubMed ID: 28834822
    [TBL] [Abstract][Full Text] [Related]  

  • 16. AO distractor and manual traction reduction techniques repair in distal tibial fractures: a comparative study.
    Wu HJ; He YX; Hang C; Hao L; Lin TK
    BMC Musculoskelet Disord; 2022 Dec; 23(1):1081. PubMed ID: 36503513
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Comparison study on two operations for treatment of extra-articular distal tibial fracture].
    Qi H; Li W; Zhao Y; Zhang Y; Liu Z; Jia J
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Nov; 27(11):1286-90. PubMed ID: 24501883
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Successful outcome with minimally invasive plate osteosynthesis for periprosthetic tibial fracture after total knee arthroplasty.
    Kim HJ; Park KC; Kim JW; Oh CW; Kyung HS; Oh JK; Park KH; Yoon SD
    Orthop Traumatol Surg Res; 2017 Apr; 103(2):263-268. PubMed ID: 27890690
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcomes following minimally invasive plate osteosynthesis (MIPO) application in tibial pilon fractures - A systematic review.
    Sourougeon Y; Barzilai Y; Haba Y; Spector B; Prat D
    Foot Ankle Surg; 2023 Dec; 29(8):566-575. PubMed ID: 37532663
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Minimally invasive plate osteosynthesis of distal tibial fractures: a comparison of medial and lateral plating.
    Shon OJ; Park CH
    J Orthop Sci; 2012 Sep; 17(5):562-6. PubMed ID: 22570013
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.