These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

233 related articles for article (PubMed ID: 31320256)

  • 1. Accuracy of Cardiac Nurse Acquired and Measured Three-Dimensional Echocardiographic Left Ventricular Ejection Fraction: Comparison to Echosonographer.
    Guppy-Coles KB; Prasad SB; Smith KC; Lo A; Beard P; Ng A; Atherton JJ
    Heart Lung Circ; 2020 May; 29(5):703-709. PubMed ID: 31320256
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of training nurses to perform semi-automated three-dimensional left ventricular ejection fraction using a customised workstation-based training protocol.
    Guppy-Coles KB; Prasad SB; Smith KC; Hillier S; Lo A; Atherton JJ
    J Clin Nurs; 2015 Jun; 24(11-12):1479-88. PubMed ID: 25256918
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility of New Transthoracic Three-Dimensional Echocardiographic Automated Software for Left Heart Chamber Quantification in Children.
    Amadieu R; Hadeed K; Jaffro M; Karsenty C; Ratsimandresy M; Dulac Y; Acar P
    J Am Soc Echocardiogr; 2019 Jan; 32(1):121-134.e1. PubMed ID: 30241929
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transthoracic 3D Echocardiographic Left Heart Chamber Quantification Using an Automated Adaptive Analytics Algorithm.
    Tsang W; Salgo IS; Medvedofsky D; Takeuchi M; Prater D; Weinert L; Yamat M; Mor-Avi V; Patel AR; Lang RM
    JACC Cardiovasc Imaging; 2016 Jul; 9(7):769-782. PubMed ID: 27318718
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Reliability of Automated Three-Dimensional Echocardiography-HeartModel
    Naser N; Stankovic I; Neskovic A
    Med Arch; 2022 Aug; 76(4):259-266. PubMed ID: 36313951
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of left ventricular ejection fraction determined by automated analysis of handheld echocardiograms: A comparison of experienced and novice examiners.
    Aldaas OM; Igata S; Raisinghani A; Kraushaar M; DeMaria AN
    Echocardiography; 2019 Dec; 36(12):2145-2151. PubMed ID: 31786824
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Three-Dimensional Echocardiographic Automated Quantification of Left Heart Chamber Volumes Using an Adaptive Analytics Algorithm: Feasibility and Impact of Image Quality in Nonselected Patients.
    Medvedofsky D; Mor-Avi V; Byku I; Singh A; Weinert L; Yamat M; Kruse E; Ciszek B; Nelson A; Otani K; Takeuchi M; Lang RM
    J Am Soc Echocardiogr; 2017 Sep; 30(9):879-885. PubMed ID: 28688857
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility and Accuracy of Automated Software for Transthoracic Three-Dimensional Left Ventricular Volume and Function Analysis: Comparisons with Two-Dimensional Echocardiography, Three-Dimensional Transthoracic Manual Method, and Cardiac Magnetic Resonance Imaging.
    Tamborini G; Piazzese C; Lang RM; Muratori M; Chiorino E; Mapelli M; Fusini L; Ali SG; Gripari P; Pontone G; Andreini D; Pepi M
    J Am Soc Echocardiogr; 2017 Nov; 30(11):1049-1058. PubMed ID: 28916243
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance of new automated transthoracic three-dimensional echocardiographic software for left ventricular volumes and function assessment in routine clinical practice: Comparison with 3 Tesla cardiac magnetic resonance.
    Levy F; Dan Schouver E; Iacuzio L; Civaia F; Rusek S; Dommerc C; Marechaux S; Dor V; Tribouilloy C; Dreyfus G
    Arch Cardiovasc Dis; 2017 Nov; 110(11):580-589. PubMed ID: 28566200
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantitative assessment of left ventricular volume and ejection fraction using two-dimensional speckle tracking echocardiography.
    Nishikage T; Nakai H; Mor-Avi V; Lang RM; Salgo IS; Settlemier SH; Husson S; Takeuchi M
    Eur J Echocardiogr; 2009 Jan; 10(1):82-8. PubMed ID: 18490270
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 3D and 2D left ventricular systolic function imaging-- from ejection fraction to deformation. Cardiac resynchronization therapy--substudy.
    Szulik M; Śliwińska A; Lenarczyk R; Szymała M; Kalinowski ME; Markowicz-Pawlus E; Kalarus Z; Kukulski T
    Acta Cardiol; 2015 Feb; 70(1):21-30. PubMed ID: 26137800
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Three-dimensional full automated software in the evaluation of the left ventricle function: from theory to clinical practice.
    Barletta V; Hinojar R; Carbonell A; González-Gómez A; Fabiani I; Di Bello V; Jiménez-Nacher JJ; Zamorano J; Fernández-Golfín C
    Int J Cardiovasc Imaging; 2018 Aug; 34(8):1205-1213. PubMed ID: 29605902
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Standardized Delineation of Endocardial Boundaries in Three-Dimensional Left Ventricular Echocardiograms.
    Papachristidis A; Galli E; Geleijnse ML; Heyde B; Alessandrini M; Barbosa D; Papitsas M; Pagnano G; Theodoropoulos KC; Zidros S; Donal E; Monaghan MJ; Bernard O; D'hooge J; Bosch JG
    J Am Soc Echocardiogr; 2017 Nov; 30(11):1059-1069. PubMed ID: 28870438
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison Between 3D Echocardiography and Cardiac Magnetic Resonance Imaging (CMRI) in the Measurement of Left Ventricular Volumes and Ejection Fraction.
    Benameur N; Arous Y; Ben Abdallah N; Kraiem T
    Curr Med Imaging Rev; 2019; 15(7):654-660. PubMed ID: 32008513
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reliability of Left Ventricular Ejection Fraction from Three-Dimensional Echocardiography for Cardiotoxicity Onset Detection in Patients with Breast Cancer.
    Lorenzini C; Lamberti C; Aquilina M; Rocca A; Cortesi P; Corsi C
    J Am Soc Echocardiogr; 2017 Nov; 30(11):1103-1110. PubMed ID: 28822666
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of three-dimensional speckle-tracking echocardiography for quantitative assessment of global left ventricular function: a comparative study to three-dimensional echocardiography.
    Luis SA; Yamada A; Khandheria BK; Speranza V; Benjamin A; Ischenko M; Platts DG; Hamilton-Craig CR; Haseler L; Burstow D; Chan J
    J Am Soc Echocardiogr; 2014 Mar; 27(3):285-91. PubMed ID: 24325960
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Evaluation of the clinical suitability of automated left ventricle's fraction and volume measurements in 3-dimensional echocardiography compared to values obtained in magnetic resonance imaging (pilot study)].
    Żygadło A; Kaźnica-Wiatr M; Błaut-Jurkowska J; Knap K; Lenart-Migdalska A; Smaś-Suska M; Skubera M; Urbańczyk-Zawadzka M; Podolec P; Olszowska M
    Pol Merkur Lekarski; 2017 Oct; 43(256):154-157. PubMed ID: 29084187
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Left ventricular volumes and ejection fraction quantification using an automated three-dimensional adaptive analytic echocardiographic algorithm in pediatric population.
    Carvajal-Rivera JJ; López-Quintero JC; González-Menchén C; de Agustín JA; Macaya C; Pérez de Isla L
    Echocardiography; 2018 Nov; 35(11):1827-1834. PubMed ID: 30151866
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy of an automated transthoracic echocardiographic tool for 3D assessment of left heart chamber volumes.
    Spitzer E; Ren B; Soliman OI; Zijlstra F; Van Mieghem NM; Geleijnse ML
    Echocardiography; 2017 Feb; 34(2):199-209. PubMed ID: 28240430
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Echocardiographic evaluation of left ventricular function using an automated analysis algorithm is feasible for beginners and experts: comparison with invasive and non-invasive methods.
    Nicol P; Rank A; Lenz T; Schürmann F; Syryca F; Trenkwalder T; Reinhard W; Adolf R; Hadamitzky M; Kastrati A; Joner M; Schunkert H; Engel LC
    J Echocardiogr; 2023 Jun; 21(2):65-73. PubMed ID: 36227498
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.