These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 31326428)

  • 1. Lithotripsy-Assisted Aortic Valvuloplasty During TAVR.
    Sardella G; Salvi N; Bruno E; Colantonio R; Mancone M
    JACC Cardiovasc Interv; 2019 Aug; 12(15):e131-e132. PubMed ID: 31326428
    [No Abstract]   [Full Text] [Related]  

  • 2. Pinhole Balloon Rupture During Valve Alignment in TAVR Using SAPIEN 3.
    Kadoya Y; Zen K; Kuwabara K; Ito N; Yamano T; Nakamura T; Matoba S
    JACC Cardiovasc Interv; 2019 Jun; 12(12):1188-1189. PubMed ID: 31153839
    [No Abstract]   [Full Text] [Related]  

  • 3. Clinical and hemodynamic results after direct transcatheter aortic valve replacement versus pre-implantation balloon aortic valvuloplasty: A case-matched analysis.
    Ferrera C; Nombela-Franco L; Garcia E; Jimenez-Quevedo P; Biagioni C; Gonzalo N; Nuñez-Gil I; Viana-Tejedor A; Salinas P; Alberto de Agustin J; Almeria C; Islas F; Perez de Isla L; Fernandez-Perez C; Escaned J; Fernández-Ortiz A; Macaya C
    Catheter Cardiovasc Interv; 2017 Nov; 90(5):809-816. PubMed ID: 27515377
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Deformation of Stabilization Arch Following Post-Dilatation of Symetis ACURATE Neo Aortic Bioprosthesis.
    Putrino AL; Roper D; Raffel CO; Walters DL
    JACC Cardiovasc Interv; 2018 Mar; 11(6):605-606. PubMed ID: 29501541
    [No Abstract]   [Full Text] [Related]  

  • 5. Vascular Injury Caused by Retrieval of Ruptured and Detached Balloon Valvuloplasty Catheter During Transcatheter Aortic Valve Replacement.
    Kubo S; Fuku Y; Shimamoto T; Kuwayama A; Ohya M; Amano H; Maruo T; Goto T; Komiya T; Kadota K
    JACC Cardiovasc Interv; 2017 Aug; 10(15):1593-1595. PubMed ID: 28734884
    [No Abstract]   [Full Text] [Related]  

  • 6. Complicated Interaction Between Balloon Expandable Sheath and Self-Expanding Aortic Bioprosthesis.
    Ihdayhid AR; Michail M; McCormick L; Gooley R
    JACC Cardiovasc Interv; 2020 Jan; 13(2):e11-e13. PubMed ID: 31564595
    [No Abstract]   [Full Text] [Related]  

  • 7. Outcomes of Direct Transcatheter Aortic Valve Replacement Without Balloon Aortic Valvuloplasty Using a New Generation Valve.
    Aalaei-Andabili SH; Beaver TM; Bavry AA; Petersen JW; Karimi A; Wayangankar S; Arnaoutakis G; Anderson RD
    Cardiovasc Revasc Med; 2019 Dec; 20(12):1100-1104. PubMed ID: 30826204
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Novel 35-mm Balloon-Expandable Transcatheter Aortic Valve Replacement.
    Jose J; George PV; Riyaz Mirza SU; Mathen PG; Selvaraj S; Raja H
    JACC Cardiovasc Interv; 2024 Apr; 17(8):1057-1059. PubMed ID: 38520457
    [No Abstract]   [Full Text] [Related]  

  • 9. Urgent Balloon Aortic Valvuloplasty or Urgent TAVR in Patients With Severe Aortic Stenosis: A Propensity-Matched Analysis.
    Bandyopadhyay D; Chakraborty S; Amgai B; Patel N; Hajra A; Ghosh RK; Kolte D; Fonarow GC; Ramee SR; Lavie CJ; Abbott JD
    JACC Cardiovasc Interv; 2020 Jan; 13(2):274-275. PubMed ID: 31973805
    [No Abstract]   [Full Text] [Related]  

  • 10. Valvuloplasty balloon entrapment in a self-expanding aortic valve stent frame after inadvertent wire passage through the outflow struts.
    Piayda K; Hellhammer K; Veulemans V; Zeus T
    Catheter Cardiovasc Interv; 2019 Jan; 93(1):174-177. PubMed ID: 30244518
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Complications after Transfemoral Transcatheter Aortic Valve Replacement with a Balloon-Expandable Prosthesis: The Importance of Preventative Measures and Contingency Planning.
    Chakravarty T; Jilaihawi H; Doctor N; Fontana G; Forrester JS; Cheng W; Makkar R
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):E29-E42. PubMed ID: 23436313
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Aborted TAVR following aortic balloon valvuloplasty.
    Algarni KD; Greason KL; Suri RM; Michelena HI; Maalouf JF
    J Card Surg; 2015 Mar; 30(3):251-2. PubMed ID: 25202824
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mitral Regurgitation After Transcatheter Aortic Valve Replacement: Prognosis, Imaging Predictors, and Potential Management.
    Cortés C; Amat-Santos IJ; Nombela-Franco L; Muñoz-Garcia AJ; Gutiérrez-Ibanes E; De La Torre Hernandez JM; Córdoba-Soriano JG; Jimenez-Quevedo P; Hernández-García JM; Gonzalez-Mansilla A; Ruano J; Jimenez-Mazuecos J; Castrodeza J; Tobar J; Islas F; Revilla A; Puri R; Puerto A; Gómez I; Rodés-Cabau J; San Román JA
    JACC Cardiovasc Interv; 2016 Aug; 9(15):1603-14. PubMed ID: 27491611
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ninety years old in good shape: when valvuloplasty and when trans-catheter aortic valve implantation for aortic stenosis?
    Pilato G; Tamburino CI; Tamburino C
    J Cardiovasc Med (Hagerstown); 2018 Feb; 19 Suppl 1():e120-e122. PubMed ID: 29538159
    [No Abstract]   [Full Text] [Related]  

  • 15. A Highly Predictive Risk Model for Pacemaker Implantation After TAVR.
    Maeno Y; Abramowitz Y; Kawamori H; Kazuno Y; Kubo S; Takahashi N; Mangat G; Okuyama K; Kashif M; Chakravarty T; Nakamura M; Cheng W; Friedman J; Berman D; Makkar RR; Jilaihawi H
    JACC Cardiovasc Imaging; 2017 Oct; 10(10 Pt A):1139-1147. PubMed ID: 28412434
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High Gradient Following Transcatheter Aortic Valve Replacement.
    Kearney A; Alkhalil M; Spence MS; Owens C
    JACC Cardiovasc Interv; 2019 Sep; 12(18):1865-1866. PubMed ID: 31537288
    [No Abstract]   [Full Text] [Related]  

  • 17. Feasibility, safety, and efficacy of transcatheter aortic valve replacement without balloon predilation: A systematic review and meta-analysis.
    Auffret V; Regueiro A; Campelo-Parada F; Del Trigo M; Chiche O; Chamandi C; Puri R; Rodés-Cabau J
    Catheter Cardiovasc Interv; 2017 Nov; 90(5):839-850. PubMed ID: 28403562
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Neurological Events Following Transcatheter Aortic Valve Replacement and Their Predictors: A Report From the CoreValve Trials.
    Kleiman NS; Maini BJ; Reardon MJ; Conte J; Katz S; Rajagopal V; Kauten J; Hartman A; McKay R; Hagberg R; Huang J; Popma J;
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27601429
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pre-Dilatation Versus No Pre-Dilatation for Implantation of a Self-Expanding Valve in All Comers Undergoing TAVR: The DIRECT Trial.
    Toutouzas K; Benetos G; Voudris V; Drakopoulou M; Stathogiannis K; Latsios G; Synetos A; Antonopoulos A; Kosmas E; Iakovou I; Katsimagklis G; Mastrokostopoulos A; Moraitis S; Zeniou V; Danenberg H; Vavuranakis M; Tousoulis D
    JACC Cardiovasc Interv; 2019 Apr; 12(8):767-777. PubMed ID: 30928442
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of prosthesis-iteration evolution and sizing practice on the incidence of prosthesis-patient mismatch after transcatheter aortic valve replacement.
    Abdelghani M; Allali A; Kaur J; Hemetsberger R; Mehilli J; Neumann FJ; Frerker C; Kurz T; El-Mawardy M; Richardt G; Abdel-Wahab M
    Catheter Cardiovasc Interv; 2019 Apr; 93(5):971-979. PubMed ID: 30467966
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.