These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
215 related articles for article (PubMed ID: 31327776)
1. [Characterization of Small Volume Plastic Scintillation Detector]. Fukui Y; Hamada Y; Noma K; Harada N Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(7):652-658. PubMed ID: 31327776 [TBL] [Abstract][Full Text] [Related]
2. Dosimetric characterization and behaviour in small X-ray fields of a microchamber and a plastic scintillator detector. Pasquino M; Cutaia C; Radici L; Valzano S; Gino E; Cavedon C; Stasi M Br J Radiol; 2017 Jan; 90(1069):20160596. PubMed ID: 27826990 [TBL] [Abstract][Full Text] [Related]
3. Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry. Galavis PE; Hu L; Holmes S; Das IJ Med Phys; 2019 May; 46(5):2468-2476. PubMed ID: 30897221 [TBL] [Abstract][Full Text] [Related]
4. Fabrication and characterization of a stemless plastic scintillation detector. Hupman MA; Monajemi T; Valitova I; Hill IG; Syme A Med Phys; 2020 Nov; 47(11):5882-5889. PubMed ID: 32966652 [TBL] [Abstract][Full Text] [Related]
5. Dosimetric characterization of a novel commercial plastic scintillation detector with an MR-Linac. Ferrer C; Huertas C; García D; Sáez M Med Phys; 2023 Apr; 50(4):2525-2539. PubMed ID: 36611266 [TBL] [Abstract][Full Text] [Related]
6. Technical Note: Evaluation of plastic scintillator detector for small field stereotactic patient-specific quality assurance. Qin Y; Gardner SJ; Kim J; Huang Y; Wen N; Doemer A; Chetty IJ Med Phys; 2017 Oct; 44(10):5509-5516. PubMed ID: 28714067 [TBL] [Abstract][Full Text] [Related]
7. High spatial resolution inorganic scintillator detector for high-energy X-ray beam at small field irradiation. Debnath SBC; Fauquet C; Tallet A; Goncalves A; Lavandier S; Jandard F; Tonneau D; Darreon J Med Phys; 2020 Mar; 47(3):1364-1371. PubMed ID: 31883388 [TBL] [Abstract][Full Text] [Related]
8. Characterizing the response of miniature scintillation detectors when irradiated with proton beams. Archambault L; Polf JC; Beaulieu L; Beddar S Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543 [TBL] [Abstract][Full Text] [Related]
9. Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors. Klein DM; Tailor RC; Archambault L; Wang L; Therriault-Proulx F; Beddar AS Med Phys; 2010 Oct; 37(10):5541-9. PubMed ID: 21089789 [TBL] [Abstract][Full Text] [Related]
10. A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy. Guillot M; Beaulieu L; Archambault L; Beddar S; Gingras L Med Phys; 2011 Dec; 38(12):6763-74. PubMed ID: 22149858 [TBL] [Abstract][Full Text] [Related]
11. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife. Morin J; Beliveau-Nadeau D; Chung E; Seuntjens J; Theriault D; Archambault L; Beddar S; Beaulieu L Med Phys; 2013 Jan; 40(1):011719. PubMed ID: 23298089 [TBL] [Abstract][Full Text] [Related]
12. Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy. Ebenau M; Radeck D; Bambynek M; Sommer H; Flühs D; Spaan B; Eichmann M Med Phys; 2016 Aug; 43(8):4598. PubMed ID: 27487876 [TBL] [Abstract][Full Text] [Related]
13. Small field dose measurements using plastic scintillation detector in heterogeneous media. Xue J; McKay JD; Grimm J; Cheng CW; Berg R; Grimm SL; Xu Q; Subedi G; Das IJ Med Phys; 2017 Jul; 44(7):3815-3820. PubMed ID: 28398596 [TBL] [Abstract][Full Text] [Related]
14. Exradin W1 plastic scintillation detector for in vivo skin dosimetry in passive scattering proton therapy. Alsanea F; Wootton L; Sahoo N; Kudchadker R; Mahmood U; Beddar S Phys Med; 2018 Mar; 47():58-63. PubMed ID: 29609819 [TBL] [Abstract][Full Text] [Related]
15. Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. Beddar AS; Mackie TR; Attix FH Phys Med Biol; 1992 Oct; 37(10):1901-13. PubMed ID: 1438555 [TBL] [Abstract][Full Text] [Related]
16. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography. Hoerner MR; Stepusin EJ; Hyer DE; Hintenlang DE Med Phys; 2015 Mar; 42(3):1268-79. PubMed ID: 25735282 [TBL] [Abstract][Full Text] [Related]
17. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance. Gagnon JC; Thériault D; Guillot M; Archambault L; Beddar S; Gingras L; Beaulieu L Med Phys; 2012 Jan; 39(1):429-36. PubMed ID: 22225313 [TBL] [Abstract][Full Text] [Related]
18. Passively scattered proton beam entrance dosimetry with a plastic scintillation detector. Wootton L; Holmes C; Sahoo N; Beddar S Phys Med Biol; 2015 Feb; 60(3):1185-98. PubMed ID: 25591037 [TBL] [Abstract][Full Text] [Related]
19. Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques. Togno M; Wilkens JJ; Menichelli D; Oechsner M; Perez-Andujar A; Morin O Med Phys; 2016 May; 43(5):2283. PubMed ID: 27147340 [TBL] [Abstract][Full Text] [Related]
20. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range. Lessard F; Archambault L; Plamondon M; Despres P; Therriault-Proulx F; Beddar S; Beaulieu L Med Phys; 2012 Sep; 39(9):5308-16. PubMed ID: 22957599 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]