These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 31332811)

  • 1. Hollow Notched K-Wires for Bone Drilling With Through-Tool Cooling.
    Luo Y; Chen L; Shih AJ
    J Orthop Res; 2019 Nov; 37(11):2297-2306. PubMed ID: 31332811
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Notched K-wire for low thermal damage bone drilling.
    Liu Y; Belmont B; Wang Y; Tai B; Holmes J; Shih A
    Med Eng Phys; 2017 Jul; 45():25-33. PubMed ID: 28462826
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of Heat Generation in Unidirectional Versus Oscillatory Modes During K-Wire Insertion in Bone.
    Luo Y; Chen L; Finney FT; Park DW; Talusan PG; Holmes JR; Shih AJ
    J Orthop Res; 2019 Sep; 37(9):1903-1909. PubMed ID: 31081555
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of k-wire insertion using oscillatory and unidirectional drilling modes under constant thrust force.
    Chen L; Li ADR; Symonds C; Holmes JR; Weick JW
    J Orthop Res; 2022 Jun; 40(6):1301-1311. PubMed ID: 34387900
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Temperature Rise in Kirschner Wires Inserted Using Two Drilling Methods: Forward and Oscillation.
    Anderson SR; Inceoglu S; Wongworawat MD
    Hand (N Y); 2018 Jul; 13(4):423-427. PubMed ID: 28511590
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro comparison of conventional surgical and rotary ultrasonic bone drilling techniques.
    Gupta V; Singh RP; Pandey PM; Gupta R
    Proc Inst Mech Eng H; 2020 Apr; 234(4):398-411. PubMed ID: 32026750
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of cortical bone drilling induced heat production among common drilling tools.
    Palmisano AC; Tai BL; Belmont B; Irwin TA; Shih A; Holmes JR
    J Orthop Trauma; 2015 May; 29(5):e188-93. PubMed ID: 25233167
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of K-wire Reuse and Drill Mode on Heat Generation in Bone.
    Muriuki MG; Reddy AK; Tauchen A; Havey RM; Patwardhan AG; Bindra RR
    Hand (N Y); 2023 Mar; 18(2):314-319. PubMed ID: 33985362
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental investigation of temperature rise in bone drilling with cooling: A comparison between modes of without cooling, internal gas cooling, and external liquid cooling.
    Shakouri E; Haghighi Hassanalideh H; Gholampour S
    Proc Inst Mech Eng H; 2018 Jan; 232(1):45-53. PubMed ID: 29153053
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Heat accumulation during sequential cortical bone drilling.
    Palmisano AC; Tai BL; Belmont B; Irwin TA; Shih A; Holmes JR
    J Orthop Res; 2016 Mar; 34(3):463-70. PubMed ID: 26334198
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rotary ultrasonic drilling on bone: A novel technique to put an end to thermal injury to bone.
    Gupta V; Pandey PM; Gupta RK; Mridha AR
    Proc Inst Mech Eng H; 2017 Mar; 231(3):189-196. PubMed ID: 28116985
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental study of bone drilling by Kirschner wire.
    Song S; Cheng X; Li T; Shi M; Zheng G; Liu H
    Med Eng Phys; 2022 Aug; 106():103835. PubMed ID: 35926958
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Drilling efficiency and temperature elevation of three types of Kirschner-wire point.
    Piska M; Yang L; Reed M; Saleh M
    J Bone Joint Surg Br; 2002 Jan; 84(1):137-40. PubMed ID: 11837819
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hammering versus drilling of sharp and obtuse trocar-point k-wires.
    Franssen BB; Schuurman AH; Mink Van Der Molen AB; Kon M
    J Hand Surg Eur Vol; 2009 Apr; 34(2):215-8. PubMed ID: 19282409
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Numerical evaluation of sequential bone drilling strategies based on thermal damage.
    Tai BL; Palmisano AC; Belmont B; Irwin TA; Holmes J; Shih AJ
    Med Eng Phys; 2015 Sep; 37(9):855-61. PubMed ID: 26163230
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Drilling K-wires, what about the osteocytes? An experimental study in rabbits.
    Franssen BB; van Diest PJ; Schuurman AH; Kon M
    Arch Orthop Trauma Surg; 2008 Jan; 128(1):83-7. PubMed ID: 17598116
    [TBL] [Abstract][Full Text] [Related]  

  • 17. One century of Kirschner wires and Kirschner wire insertion techniques: a historical review.
    Franssen BB; Schuurman AH; Van der Molen AM; Kon M
    Acta Orthop Belg; 2010 Feb; 76(1):1-6. PubMed ID: 20306956
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Exploring thermal anisotropy of cortical bone using temperature measurements in drilling.
    Alam K
    Biomed Mater Eng; 2016 May; 27(1):39-48. PubMed ID: 27175466
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill.
    Augustin G; Davila S; Udilljak T; Staroveski T; Brezak D; Babic S
    Int Orthop; 2012 Jul; 36(7):1449-56. PubMed ID: 22290154
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimal parameters to avoid thermal necrosis during bone drilling: A finite element analysis.
    Mediouni M; Schlatterer DR; Khoury A; Von Bergen T; Shetty SH; Arora M; Dhond A; Vaughan N; Volosnikov A
    J Orthop Res; 2017 Nov; 35(11):2386-2391. PubMed ID: 28181707
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.