BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

678 related articles for article (PubMed ID: 31337425)

  • 1. Accuracy and complications of CT-guided pulmonary core biopsy in small nodules: a single-center experience.
    Huang MD; Weng HH; Hsu SL; Hsu LS; Lin WM; Chen CW; Tsai YH
    Cancer Imaging; 2019 Jul; 19(1):51. PubMed ID: 31337425
    [TBL] [Abstract][Full Text] [Related]  

  • 2. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions.
    Li Y; Du Y; Yang HF; Yu JH; Xu XX
    Clin Radiol; 2013 Jan; 68(1):e43-8. PubMed ID: 23177650
    [TBL] [Abstract][Full Text] [Related]  

  • 3. CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy.
    Andrade JR; Rocha RD; Falsarella PM; Rahal Junior A; Santos RSD; Franceschini JP; Fernando HC; Garcia RG
    J Bras Pneumol; 2018; 44(4):307-314. PubMed ID: 30328929
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CT-guided fine-needle aspiration and core needle biopsies of pulmonary lesions: a single-center experience with 750 biopsies in Japan.
    Takeshita J; Masago K; Kato R; Hata A; Kaji R; Fujita S; Katakami N
    AJR Am J Roentgenol; 2015 Jan; 204(1):29-34. PubMed ID: 25539234
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dependent lesion positioning at CT-guided lung biopsy to reduce risk of pneumothorax.
    Appel E; Dommaraju S; Camacho A; Nakhaei M; Siewert B; Ahmed M; Brook A; Brook OR
    Eur Radiol; 2020 Nov; 30(11):6369-6375. PubMed ID: 32591892
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients.
    Nour-Eldin NE; Alsubhi M; Emam A; Lehnert T; Beeres M; Jacobi V; Gruber-Rouh T; Scholtz JE; Vogl TJ; Naguib NN
    Cardiovasc Intervent Radiol; 2016 Feb; 39(2):261-70. PubMed ID: 26148648
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pneumothorax Rate and Diagnostic Adequacy of Computed Tomography-guided Lung Nodule Biopsies Performed With 18 G Versus 20 G Needles: A Cross-Sectional Study.
    Kolderman NC; Cheti DR; Hasbrook CD; Forsyth AJ; Coffey MP; Nair GB; Al-Katib SA
    J Thorac Imaging; 2020 Jul; 35(4):265-269. PubMed ID: 32032253
    [TBL] [Abstract][Full Text] [Related]  

  • 8. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years.
    Yin Z; Liang Z; Li P; Wang Q
    Eur Radiol; 2017 Aug; 27(8):3401-3407. PubMed ID: 28050696
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Risk factors for pneumothorax and pulmonary hemorrhage following computed tomography-guided transthoracic core-needle biopsy of subpleural lung lesions.
    Chiu JH; Chang YY; Weng CY; Lee YC; Yeh YC; Chen CK
    J Chin Med Assoc; 2022 Apr; 85(4):500-506. PubMed ID: 35383704
    [TBL] [Abstract][Full Text] [Related]  

  • 10. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate.
    Geraghty PR; Kee ST; McFarlane G; Razavi MK; Sze DY; Dake MD
    Radiology; 2003 Nov; 229(2):475-81. PubMed ID: 14595149
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Complications of CT-guided lung biopsy with a non-coaxial semi-automated 18 gauge biopsy system: Frequency, severity and risk factors.
    Elshafee AS; Karch A; Ringe KI; Shin HO; Raatschen HJ; Soliman NY; Wacker F; Vogel-Claussen J
    PLoS One; 2019; 14(3):e0213990. PubMed ID: 30883575
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Effect of Needle Gauge on the Risk of Pneumothorax and Chest Tube Placement After Percutaneous Computed Tomographic (CT)-Guided Lung Biopsy.
    Kuban JD; Tam AL; Huang SY; Ensor JE; Philip AS; Chen GJ; Ahrar J; Murthy R; Avritscher R; Madoff DC; Mahvash A; Ahrar K; Wallace MJ; Nachiappan AC; Gupta S
    Cardiovasc Intervent Radiol; 2015 Dec; 38(6):1595-602. PubMed ID: 25920917
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Diagnostic accuracy and complications of CT-guided core needle lung biopsy of solid and part-solid lesions.
    Yun S; Kang H; Park S; Kim BS; Park JG; Jung MJ
    Br J Radiol; 2018 Jul; 91(1088):20170946. PubMed ID: 29770737
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of CT-Guided Core Needle Biopsy in Pulmonary Ground-Glass and Solid Nodules Based on Propensity Score Matching Analysis.
    An W; Zhang H; Wang B; Zhong F; Wang S; Liao M
    Technol Cancer Res Treat; 2022; 21():15330338221085357. PubMed ID: 35297696
    [No Abstract]   [Full Text] [Related]  

  • 15. CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules.
    Ohno Y; Hatabu H; Takenaka D; Higashino T; Watanabe H; Ohbayashi C; Sugimura K
    AJR Am J Roentgenol; 2003 Jun; 180(6):1665-9. PubMed ID: 12760939
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy and Safety Analysis of Multislice Spiral CT-Guided Transthoracic Lung Biopsy in the Diagnosis of Pulmonary Nodules of Different Sizes.
    Liu H; Yao X; Xu B; Zhang W; Lei Y; Chen X
    Comput Math Methods Med; 2022; 2022():8192832. PubMed ID: 36060660
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diagnostic Accuracy and Safety of CT-Guided Percutaneous Transthoracic Needle Biopsies: 14-Gauge versus 22-Gauge Needles.
    Ocak S; Duplaquet F; Jamart J; Pirard L; Weynand B; Delos M; Eucher P; Rondelet B; Dupont M; Delaunois L; Sibille Y; Dahlqvist C
    J Vasc Interv Radiol; 2016 May; 27(5):674-81. PubMed ID: 27017121
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Small (Gupta S; Krishnamurthy S; Broemeling LD; Morello FA; Wallace MJ; Ahrar K; Madoff DC; Murthy R; Hicks ME
    Radiology; 2005 Feb; 234(2):631-7. PubMed ID: 15673500
    [TBL] [Abstract][Full Text] [Related]  

  • 19. CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle.
    Laurent F; Latrabe V; Vergier B; Montaudon M; Vernejoux JM; Dubrez J
    Clin Radiol; 2000 Apr; 55(4):281-7. PubMed ID: 10767187
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computed tomography fluoroscopy-guided cutting needle biopsy of pulmonary nodules ≤8 mm: A retrospective study including 117 nodules.
    Zhao Y; Matsui Y; Hiraki T; Iguchi T; Tomita K; Uka M; Gobara H; Toyooka S; Kanazawa S
    Eur J Radiol; 2020 Apr; 125():108903. PubMed ID: 32088660
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 34.