BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 31338496)

  • 1. Portable linear ion trap mass spectrometer with compact multistage vacuum system and continuous atmospheric pressure interface.
    Li X; Zhang Y; Ge S; Qian J; Miao W
    Analyst; 2019 Aug; 144(17):5127-5135. PubMed ID: 31338496
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mini Mass Spectrometer Integrated with a Miniature Ion Funnel.
    Zhai Y; Zhang X; Xu H; Zheng Y; Yuan T; Xu W
    Anal Chem; 2017 Apr; 89(7):4177-4183. PubMed ID: 28252284
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and characterization of a field-deployable ion-trap mass spectrometer with an atmospheric pressure interface.
    Misharin A; Novoselov K; Laiko V; Doroshenko VM
    Anal Chem; 2012 Nov; 84(22):10105-12. PubMed ID: 23116334
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Atmospheric pressure ionization in a miniature mass spectrometer.
    Laughlin BC; Mulligan CC; Cooks RG
    Anal Chem; 2005 May; 77(9):2928-39. PubMed ID: 15859613
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of a low power miniature linear ion trap mass spectrometer with extended mass range.
    Li G; Li D; Cheng Y; Pei X; Zhang H; Wang Y; Sun J; Dong M
    Rev Sci Instrum; 2017 Dec; 88(12):123108. PubMed ID: 29289174
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Breaking the pumping speed barrier in mass spectrometry: discontinuous atmospheric pressure interface.
    Gao L; Cooks RG; Ouyang Z
    Anal Chem; 2008 Jun; 80(11):4026-32. PubMed ID: 18461971
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rectilinear ion trap mass spectrometer with atmospheric pressure interface and electrospray ionization source.
    Song Q; Kothari S; Senko MA; Schwartz JC; Amy JW; Stafford GC; Cooks RG; Ouyang Z
    Anal Chem; 2006 Feb; 78(3):718-25. PubMed ID: 16448044
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Discontinuous Subatmospheric Pressure Interface Reduces the Gas Flow Effects on Miniature CAPI Mass Spectrometer.
    Huo X; Zhu X; Tang F; Zhang J; Zhang X; Yu Q; Wang X
    Anal Chem; 2020 Mar; 92(5):3707-3715. PubMed ID: 31961668
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development and application of a miniature mass spectrometer with continuous sub-atmospheric pressure interface and integrated ionization source.
    Zhu Y; Zhang R; Wang K; Lu J; Lin L; Yang L; Zhang Q; Wang X; Yu Q
    Talanta; 2023 Feb; 253():123994. PubMed ID: 36228556
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of a miniature mass spectrometer with continuous atmospheric pressure interface.
    Zhai Y; Feng Y; Wei Y; Wang Y; Xu W
    Analyst; 2015 May; 140(10):3406-14. PubMed ID: 25860539
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An aerodynamic assisted miniature mass spectrometer for enhanced volatile sample analysis.
    Zhai Y; Jiang T; Huang G; Wei Y; Xu W
    Analyst; 2016 Sep; 141(18):5404-11. PubMed ID: 27379359
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ambient mass spectrometry with a handheld mass spectrometer at high pressure.
    Keil A; Talaty N; Janfelt C; Noll RJ; Gao L; Ouyang Z; Cooks RG
    Anal Chem; 2007 Oct; 79(20):7734-9. PubMed ID: 17867653
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Developing a Vacuum Electrospray Source To Implement Efficient Atmospheric Sampling for Miniature Ion Trap Mass Spectrometer.
    Yu Q; Zhang Q; Lu X; Qian X; Ni K; Wang X
    Anal Chem; 2017 Dec; 89(23):12938-12944. PubMed ID: 29091419
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design and characterization of a multisource hand-held tandem mass spectrometer.
    Gao L; Sugiarto A; Harper JD; Cooks RG; Ouyang Z
    Anal Chem; 2008 Oct; 80(19):7198-205. PubMed ID: 18754674
    [TBL] [Abstract][Full Text] [Related]  

  • 15. SR-Unet: A Super-Resolution Algorithm for Ion Trap Mass Spectrometers Based on the Deep Neural Network.
    Ai J; Zhao W; Yu Q; Qian X; Zhou J; Huo X; Tang F
    Anal Chem; 2023 Nov; 95(47):17407-17415. PubMed ID: 37963290
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multiplexing Quadrupole and Ion Trap Operation Modes on a "Brick" Miniature Mass Spectrometer.
    Feng C; Liu S; Jiang T; Xu W
    Molecules; 2023 Nov; 28(22):. PubMed ID: 38005361
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design and performance evaluation of a linear ion trap mass analyzer featuring half round rod electrodes.
    Li X; Zhang X; Yao R; He Y; Zhu Y; Qian J
    J Am Soc Mass Spectrom; 2015 May; 26(5):734-40. PubMed ID: 25753973
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Boosting the Sensitivity and Selectivity of a Miniature Mass Spectrometer Using a Hybrid Ion Funnel.
    Zhai Y; Xu Q; Tang Y; Liu S; Li D; Xu W
    Anal Chem; 2019 Jun; 91(12):7911-7919. PubMed ID: 31137927
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel asymmetrical arc-shaped electrode ion trap for improving the performance of a miniature mass spectrometer.
    Zhang ZY; Li C; Ding CF; Xu F; Li B; Huang Q; Xia H
    Rapid Commun Mass Spectrom; 2014 Aug; 28(15):1764-8. PubMed ID: 24975257
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mini 12, miniature mass spectrometer for clinical and other applications--introduction and characterization.
    Li L; Chen TC; Ren Y; Hendricks PI; Cooks RG; Ouyang Z
    Anal Chem; 2014 Mar; 86(6):2909-16. PubMed ID: 24521423
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.