These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 31340564)

  • 21. Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring.
    Schwartz G; Tee BC; Mei J; Appleton AL; Kim DH; Wang H; Bao Z
    Nat Commun; 2013; 4():1859. PubMed ID: 23673644
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Self-Powered Multiparameter Health Sensor.
    Tobola A; Leutheuser H; Pollak M; Spies P; Hofmann C; Weigand C; Eskofier BM; Fischer G
    IEEE J Biomed Health Inform; 2018 Jan; 22(1):15-22. PubMed ID: 28574370
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A system for monitoring heart pulse, respiration and posture in bed.
    Miyamoto Y; Yonezawa Y; Maki H; Ogawa H; Hahn AW; Caldwell WM
    Biomed Sci Instrum; 2002; 38():135-8. PubMed ID: 12085590
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Signal phase estimation for measurement of respiration waveform using a microwave Doppler sensor.
    Noguchi H; Kubo H; Mori T; Sato T; Sanada H
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():6740-3. PubMed ID: 24111290
    [TBL] [Abstract][Full Text] [Related]  

  • 25. New noninvasive piezoelectric transducer for recording of respiration, heart rate and body movements.
    Siivola J
    Med Biol Eng Comput; 1989 Jul; 27(4):423-5. PubMed ID: 2601470
    [No Abstract]   [Full Text] [Related]  

  • 26. Assessment of a new piezoelectric transducer sensor for noninvasive cardiorespiratory monitoring of newborn infants in the NICU.
    Sato S; Ishida-Nakajima W; Ishida A; Kawamura M; Miura S; Ono K; Inagaki N; Takada G; Takahashi T
    Neonatology; 2010; 98(2):179-90. PubMed ID: 20234143
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Fundamental study of measurement of cardiorespiratory signals in a sitting position using piezoelectric sensors.
    Igasaki T; Yoshikawa K; Murayama N
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():3841-4. PubMed ID: 24110569
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Camera-based system for contactless monitoring of respiration.
    Bartula M; Tigges T; Muehlsteff J
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():2672-5. PubMed ID: 24110277
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds.
    Andreozzi E; Gargiulo GD; Esposito D; Bifulco P
    Front Physiol; 2021; 12():725716. PubMed ID: 34867438
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Noninvasive respiration movement sensor based on distributed Bragg reflector fiber laser with beat frequency interrogation.
    Wo J; Wang H; Sun Q; Shum PP; Liu D
    J Biomed Opt; 2014 Jan; 19(1):17003. PubMed ID: 24441944
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Noncontact Monitoring of Respiration by Dynamic Air-Pressure Sensor.
    Takarada T; Asada T; Sumi Y; Higuchi Y
    Anesth Prog; 2015; 62(3):100-5. PubMed ID: 26398125
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Journal of Clinical Monitoring and Computing 2016 end of year summary: respiration.
    Karbing DS; Rees SE; Jaffe MB
    J Clin Monit Comput; 2017 Apr; 31(2):247-252. PubMed ID: 28255799
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Journal of Clinical Monitoring and Computing 2017 end of year summary: respiration.
    Karbing DS; Perchiazzi G; Rees SE; Jaffe MB
    J Clin Monit Comput; 2018 Apr; 32(2):197-205. PubMed ID: 29480384
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Flexible Piezoelectric Sensor-Based Gait Recognition.
    Cha Y; Kim H; Kim D
    Sensors (Basel); 2018 Feb; 18(2):. PubMed ID: 29401752
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Phantom study evaluating detection of simulated upper airway occlusion using piezoelectric ultrasound transducers.
    Al-Abed M; Antich P; Watenpaugh DE; Behbehani K
    Comput Biol Med; 2017 Oct; 89():325-336. PubMed ID: 28863405
    [TBL] [Abstract][Full Text] [Related]  

  • 36. REM sleep estimation only using respiratory dynamics.
    Chung GS; Choi BH; Lee JS; Lee JS; Jeong DU; Park KS
    Physiol Meas; 2009 Dec; 30(12):1327-40. PubMed ID: 19864705
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Noninvasive respiratory monitoring system based on the piezoceramic transducer's pyroelectric effect.
    Huang YP; Young MS; Tai CC
    Rev Sci Instrum; 2008 Mar; 79(3):035103. PubMed ID: 18377041
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Paper-Based Electrical Respiration Sensor.
    Güder F; Ainla A; Redston J; Mosadegh B; Glavan A; Martin TJ; Whitesides GM
    Angew Chem Int Ed Engl; 2016 May; 55(19):5727-32. PubMed ID: 27059088
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Unobtrusive online monitoring of sleep at home.
    Paalasmaa J; Waris M; Toivonen H; Leppäkorpi L; Partinen M
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():3784-8. PubMed ID: 23366752
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Use of a piezoelectric film sensor for monitoring vascular grafts.
    Gupta SK; Dietzek AM; Veith FJ; Torres M; Kram HB; Wengerter KR
    Am J Surg; 1990 Aug; 160(2):182-5; discussion 185-6. PubMed ID: 2382771
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.