BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

999 related articles for article (PubMed ID: 31343826)

  • 21. Helical tomotherapy vs. intensity-modulated proton therapy for whole pelvis irradiation in high-risk prostate cancer patients: dosimetric, normal tissue complication probability, and generalized equivalent uniform dose analysis.
    Widesott L; Pierelli A; Fiorino C; Lomax AJ; Amichetti M; Cozzarini C; Soukup M; Schneider R; Hug E; Di Muzio N; Calandrino R; Schwarz M
    Int J Radiat Oncol Biol Phys; 2011 Aug; 80(5):1589-600. PubMed ID: 21167651
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Introducing Proton Track-End Objectives in Intensity Modulated Proton Therapy Optimization to Reduce Linear Energy Transfer and Relative Biological Effectiveness in Critical Structures.
    Traneus E; Ödén J
    Int J Radiat Oncol Biol Phys; 2019 Mar; 103(3):747-757. PubMed ID: 30395906
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions.
    Zeng C; Giantsoudi D; Grassberger C; Goldberg S; Niemierko A; Paganetti H; Efstathiou JA; Trofimov A
    Med Phys; 2013 May; 40(5):051708. PubMed ID: 23635256
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Monte Carlo evaluation of tissue heterogeneities corrections in the treatment of head and neck cancer patients using stereotactic radiotherapy.
    Pokhrel D; McClinton C; Sood S; Badkul R; Saleh H; Jiang H; Lominska C
    J Appl Clin Med Phys; 2016 Mar; 17(2):258-270. PubMed ID: 27074489
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Investigation of four-dimensional (4D) Monte Carlo dose calculation in real-time tumor tracking stereotatic body radiotherapy for lung cancers.
    Chan MK; Kwong DL; Ng SC; Tam EK; Tong AS
    Med Phys; 2012 Sep; 39(9):5479-87. PubMed ID: 22957615
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Impact of TPS calculation algorithms on dose delivered to the patient in proton therapy treatments.
    Molinelli S; Russo S; Magro G; Maestri D; Mairani A; Mastella E; Mirandola A; Vai A; Vischioni B; Valvo F; Ciocca M
    Phys Med Biol; 2019 Apr; 64(7):075016. PubMed ID: 30802887
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Small spot size versus large spot size: Effect on plan quality for lung cancer in pencil beam scanning proton therapy.
    Rana S; Rosenfeld AB
    J Appl Clin Med Phys; 2022 Feb; 23(2):e13512. PubMed ID: 34989458
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Clinical evaluation of X-ray voxel Monte Carlo versus pencil beam-based dose calculation in stereotactic body radiotherapy of lung cancer under normal and deep inspiration breath hold.
    Landoni V; Borzì GR; Strolin S; Bruzzaniti V; Soriani A; D'Alessio D; Ambesi F; Di Grazia AM; Strigari L
    Technol Cancer Res Treat; 2015 Jun; 14(3):334-42. PubMed ID: 25223324
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Validation of the RayStation Monte Carlo dose calculation algorithm using a realistic lung phantom.
    Schreuder AN; Bridges DS; Rigsby L; Blakey M; Janson M; Hedrick SG; Wilkinson JB
    J Appl Clin Med Phys; 2019 Dec; 20(12):127-137. PubMed ID: 31763759
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Spot scanning proton arc therapy reduces toxicity in oropharyngeal cancer patients.
    de Jong BA; Battinelli C; Free J; Wagenaar D; Engwall E; Janssens G; Langendijk JA; Korevaar EW; Both S
    Med Phys; 2023 Mar; 50(3):1305-1317. PubMed ID: 36373893
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of the ray-casting analytical algorithm for pencil beam scanning proton therapy.
    Winterhalter C; Zepter S; Shim S; Meier G; Bolsi A; Fredh A; Hrbacek J; Oxley D; Zhang Y; Weber DC; Lomax A; Safai S
    Phys Med Biol; 2019 Mar; 64(6):065021. PubMed ID: 30641496
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Difference in LET-based biological doses between IMPT optimization techniques: Robust and PTV-based optimizations.
    Hirayama S; Matsuura T; Yasuda K; Takao S; Fujii T; Miyamoto N; Umegaki K; Shimizu S
    J Appl Clin Med Phys; 2020 Apr; 21(4):42-50. PubMed ID: 32150329
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans.
    Bazalova-Carter M; Qu B; Palma B; Hårdemark B; Hynning E; Jensen C; Maxim PG; Loo BW
    Med Phys; 2015 May; 42(5):2615-25. PubMed ID: 25979053
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Treatment planning comparison of IMPT, VMAT and 4π radiotherapy for prostate cases.
    Tran A; Zhang J; Woods K; Yu V; Nguyen D; Gustafson G; Rosen L; Sheng K
    Radiat Oncol; 2017 Jan; 12(1):10. PubMed ID: 28077128
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Transitioning from measurement-based to combined patient-specific quality assurance for intensity-modulated proton therapy.
    Chen M; Yepes P; Hojo Y; Poenisch F; Li Y; Chen J; Xu C; He X; Gunn GB; Frank SJ; Sahoo N; Li H; Zhu XR; Zhang X
    Br J Radiol; 2020 Mar; 93(1107):20190669. PubMed ID: 31799859
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Advanced proton beam dosimetry part II: Monte Carlo
    Maes D; Saini J; Zeng J; Rengan R; Wong T; Bowen SR
    Transl Lung Cancer Res; 2018 Apr; 7(2):114-121. PubMed ID: 29876310
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Improve the dosimetric outcome in bilateral head and neck cancer (HNC) treatment using spot-scanning proton arc (SPArc) therapy: a feasibility study.
    Liu G; Li X; Qin A; Zheng W; Yan D; Zhang S; Stevens C; Kabolizadeh P; Ding X
    Radiat Oncol; 2020 Jan; 15(1):21. PubMed ID: 32000817
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer.
    Liu W; Schild SE; Chang JY; Liao Z; Chang YH; Wen Z; Shen J; Stoker JB; Ding X; Hu Y; Sahoo N; Herman MG; Vargas C; Keole S; Wong W; Bues M
    Int J Radiat Oncol Biol Phys; 2016 May; 95(1):523-533. PubMed ID: 26725727
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Impact of dose engine algorithm in pencil beam scanning proton therapy for breast cancer.
    Tommasino F; Fellin F; Lorentini S; Farace P
    Phys Med; 2018 Jun; 50():7-12. PubMed ID: 29891097
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Technical Note: Dosimetric evaluation of Monte Carlo algorithm in iPlan for stereotactic ablative body radiotherapy (SABR) for lung cancer patients using RTOG 0813 parameters.
    Pokhrel D; Badkul R; Jiang H; Kumar P; Wang F
    J Appl Clin Med Phys; 2015 Jan; 16(1):5058. PubMed ID: 25679161
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 50.