These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

245 related articles for article (PubMed ID: 31347506)

  • 1. Extra-Cochlear Insertion in Cochlear Implantation: A Potentially Disastrous Condition.
    Gözen ED; Tevetoğlu F; Yener HM; Kara E; Ataş A; Şirolu S; Kızılkılıç O; Cansız H; Karaman E
    J Int Adv Otol; 2019 Dec; 15(3):358-363. PubMed ID: 31347506
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The misplaced cochlear implant electrode array.
    Mehanna AM; Gamaleldin OA; Fathalla MF
    Int J Pediatr Otorhinolaryngol; 2019 Feb; 117():96-104. PubMed ID: 30579097
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Rare Case of Cochlear Implant Electrode Array Misplacement Into the Posterior Semicircular Canal.
    Zhao CH; Quimby AE; Bigelow DC
    Laryngoscope; 2023 Jan; 133(1):175-177. PubMed ID: 35946580
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Incomplete electrode extraction during cochlear implant revision.
    Kang SY; Zwolan TA; Kileny PR; Niparko JK; Driscoll CL; Shelton C; Telian SA
    Otol Neurotol; 2009 Feb; 30(2):160-4. PubMed ID: 19180676
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Identification and revision of a displaced cochlear implant electrode in the internal auditory canal.
    Todt I; Rademacher G; Ernst A
    Cochlear Implants Int; 2013 Sep; 14(4):236-9. PubMed ID: 23510683
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Cochlear electrode array misplacement into the superior semicircular canal: a case report and literature review].
    Sun C; Huang Z; Ma Y; Gu Y; Li Q
    Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2023 Apr; 37(4):310-312. PubMed ID: 36987965
    [No Abstract]   [Full Text] [Related]  

  • 7. Management of electrode exposure after cochlear implantation.
    Walgama ES; Isaacson B; Kutz JW; Roland PS
    Otol Neurotol; 2012 Sep; 33(7):1197-200. PubMed ID: 22892807
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An unusual occurrence in cochlear implantation surgery: misplaced electrode.
    Ramalingam R; Ramalingam KK; Padmaja HS
    J Laryngol Otol; 2009 Jan; 123(1):e4. PubMed ID: 18980706
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characteristics of electrically evoked auditory brainstem responses in patients with cochlear nerve canal stenosis receiving cochlear implants.
    Wang Z; Liu Y; Wang L; Shen X; Han S; Wang W; Gao F; Liang W; Peng KA
    Int J Pediatr Otorhinolaryngol; 2018 Jan; 104():98-103. PubMed ID: 29287891
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cochlear implant electrode misplacement: incidence, evaluation, and management.
    Ying YL; Lin JW; Oghalai JS; Williamson RA
    Laryngoscope; 2013 Mar; 123(3):757-66. PubMed ID: 23299627
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cochlear Implant Electrode Misplacement: A Case Series and Contemporary Review.
    Shin TJ; Totten DJ; Tucker BJ; Nelson RF
    Otol Neurotol; 2022 Jun; 43(5):547-558. PubMed ID: 35239619
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Foreign body reaction after cochlear implantation.
    Lim HJ; Lee ES; Park HY; Park K; Choung YH
    Int J Pediatr Otorhinolaryngol; 2011 Nov; 75(11):1455-8. PubMed ID: 21880376
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Revision cochlear implantation following internal auditory canal insertion.
    Heman-Ackah SE; Friedmann DR; Cosetti MK; Waltzman SB; Roland JT
    Laryngoscope; 2013 Dec; 123(12):3141-7. PubMed ID: 24114888
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A cool approach to reducing electrode-induced trauma: Localized therapeutic hypothermia conserves residual hearing in cochlear implantation.
    Tamames I; King C; Bas E; Dietrich WD; Telischi F; Rajguru SM
    Hear Res; 2016 Sep; 339():32-9. PubMed ID: 27260269
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Migration and other electrode complications following cochlear implantation.
    Magos T; Kanona H; Morley S; Khalil S; Shaida A
    Cochlear Implants Int; 2024 May; 25(3):239-247. PubMed ID: 38383952
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Electrode array misplacement into the superior semicircular canal: as a rare complication of cochlear implantation.
    Sun JQ; Sun JW; Hou XY; Bie YZ; Chen JW
    Int J Pediatr Otorhinolaryngol; 2014 Sep; 78(9):1537-40. PubMed ID: 25063507
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Cochlear implantation with pericanal electrode insertion technique].
    Cui T; Jiang H; Chen X; Feng G; Zhang Z; Li F; Zhao C; Gao Z; Han D; Yang S; Dai P; Li J; Xi X; Ma X; Dong Y; Yu P
    Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2011 May; 25(10):457-9. PubMed ID: 21809558
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrode migration in cochlear implant patients: not an exception.
    van der Marel KS; Verbist BM; Briaire JJ; Joemai RM; Frijns JH
    Audiol Neurootol; 2012; 17(5):275-81. PubMed ID: 22627581
    [TBL] [Abstract][Full Text] [Related]  

  • 19. X-linked Malformation and Cochlear Implantation.
    Smeds H; Wales J; Asp F; Löfkvist U; Falahat B; Anderlid BM; Anmyr L; Karltorp E
    Otol Neurotol; 2017 Jan; 38(1):38-46. PubMed ID: 27779564
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low surgical complication rates in cochlear implantation for young children less than 1 year of age.
    Kalejaiye A; Ansari G; Ortega G; Davidson M; Kim HJ
    Laryngoscope; 2017 Mar; 127(3):720-724. PubMed ID: 27411677
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.