These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 31350153)

  • 1. Horner Syndrome Caused by Internal Jugular Vein Catheterization.
    Zou ZY; Yao YT
    J Cardiothorac Vasc Anesth; 2020 Jun; 34(6):1636-1640. PubMed ID: 31350153
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A case of postganglionic Horner syndrome after catheterization of internal jugular vein confirmed with pharmacological tests.
    Büyüktortop N; Gürbüz-Köz O; Atalay T; Kural G
    Turk J Pediatr; 2008; 50(4):391-4. PubMed ID: 19014057
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasound evaluation of the anatomical characteristics of the internal jugular vein and carotid artery--facilitation of internal jugular vein cannulation.
    Sibai AN; Loutfi E; Itani M; Baraka A
    Middle East J Anaesthesiol; 2008 Oct; 19(6):1305-20. PubMed ID: 18942245
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Complications in internal jugular vs subclavian ultrasound-guided central venous catheterization: a comparative randomized trial.
    Shin HJ; Na HS; Koh WU; Ro YJ; Lee JM; Choi YJ; Park S; Kim JH
    Intensive Care Med; 2019 Jul; 45(7):968-976. PubMed ID: 31143996
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relationship of the internal jugular vein to the common carotid artery: implications for ultrasound-guided vascular access.
    Maecken T; Marcon C; Bomas S; Zenz M; Grau T
    Eur J Anaesthesiol; 2011 May; 28(5):351-5. PubMed ID: 21150630
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of the bevel direction of puncture needle on success rate and complications during internal jugular vein catheterization.
    Lim T; Ryu HG; Jung CW; Jeon Y; Bahk JH
    Crit Care Med; 2012 Feb; 40(2):491-4. PubMed ID: 21983370
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new method of internal jugular vein catheterization using the cricoid cartilage and the external jugular vein as a landmark.
    Jin Lee J; Sook Gwak M; Yang M; Soo Kim G
    Am J Emerg Med; 2006 Oct; 24(6):697-701. PubMed ID: 16984838
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Bernard-Horner syndrome after accidental lesion of carotid artery: case report].
    Spinelli G; Damiano G; Palumbo VD; Cillino G; Lo Monte AI
    Clin Ter; 2012 Jul; 163(4):e185-7. PubMed ID: 23007824
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasound simulation of internal jugular vein cannulation in pregnant and non-pregnant women.
    Siddiqui N; Goldszmidt E; Haque SU; Carvalho JC
    Can J Anaesth; 2010 Nov; 57(11):966-72. PubMed ID: 20830543
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of the central landmark for catheterization of the right internal jugular vein after placement of the ProSeal laryngeal mask airway.
    Tseng KY; Tsai CJ; Wu SH; Lu DV; Hsu HT; Lu IC; Chu KS
    Acta Anaesthesiol Taiwan; 2009 Sep; 47(3):118-22. PubMed ID: 19762301
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Ultrasound-guided puncture of the jugular vein using a posterior approach].
    Pérez Reyes JM; Bethencourt Muñoz S; Cabrejas Ibarz MT; Tejero García M; Valdivia Martín J; González Miranda F
    Rev Esp Anestesiol Reanim; 2008 Dec; 55(10):616-20. PubMed ID: 19177863
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography.
    Troianos CA; Kuwik RJ; Pasqual JR; Lim AJ; Odasso DP
    Anesthesiology; 1996 Jul; 85(1):43-8. PubMed ID: 8694381
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Horner's syndrome secondary to internal jugular venous cannulation.
    Suominen PK; Korhonen AM; Vaida SJ; Hiller AS
    J Clin Anesth; 2008 Jun; 20(4):304-6. PubMed ID: 18617132
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture.
    Sulek CA; Gravenstein N; Blackshear RH; Weiss L
    Anesth Analg; 1996 Jan; 82(1):125-8. PubMed ID: 8712386
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Position of the internal jugular vein in children. A study of the anatomy using ultrasonography.
    Mallinson C; Bennett J; Hodgson P; Petros AJ
    Paediatr Anaesth; 1999; 9(2):111-4. PubMed ID: 10189649
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Anatomic relationship of the internal jugular vein and the common carotid artery applied to percutaneous transjugular procedures.
    Turba UC; Uflacker R; Hannegan C; Selby JB
    Cardiovasc Intervent Radiol; 2005; 28(3):303-6. PubMed ID: 15770389
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of head rotation on vascular anatomy of the neck: an ultrasound study.
    Wang R; Snoey ER; Clements RC; Hern HG; Price D
    J Emerg Med; 2006 Oct; 31(3):283-6. PubMed ID: 16982362
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The success rate and safety of internal jugular vein cannulation using anatomical landmark technique in patients undergoing cardiothoracic surgery.
    Tempe DK; Virmani S; Agarwal J; Hemrajani M; Satyarthy S; Minhas HS
    Ann Card Anaesth; 2013; 16(1):16-20. PubMed ID: 23287081
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Application of ultrasonic surface location for internal jugular vein catheterization via central approach].
    Zhang YL; Mi WD; Yu DJ; Fu Q; Feng XX
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2011 Oct; 33(5):479-84. PubMed ID: 22338128
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ultrasound analysis of the relationship between right internal jugular vein and common carotid artery in the left head-rotation and head-flexion position.
    Saitoh T; Satoh H; Kumazawa A; Nobuhara M; Machii M; Tanaka T; Shiraki K; Saotome M; Urushida T; Katoh H; Hayashi H
    Heart Vessels; 2013 Sep; 28(5):620-5. PubMed ID: 22968853
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.