These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

341 related articles for article (PubMed ID: 31359232)

  • 21. Comparison of in-stent neoatherosclerosis and tissue characteristics between early and late in-stent restenosis in second-generation drug-eluting stents: an optical coherence tomography study.
    Sabbah M; Kadota K; El-Eraky A; Kamal HM; Abdellah AT; El Hawary A
    Int J Cardiovasc Imaging; 2017 Oct; 33(10):1463-1472. PubMed ID: 28444549
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Impact of coronary anatomy and stenting technique on long-term outcome after drug-eluting stent implantation for unprotected left main coronary artery disease.
    Tiroch K; Mehilli J; Byrne RA; Schulz S; Massberg S; Laugwitz KL; Vorpahl M; Seyfarth M; Kastrati A;
    JACC Cardiovasc Interv; 2014 Jan; 7(1):29-36. PubMed ID: 24332416
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of long-term in-stent vascular response between abluminal groove-filled biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent: 3-year OCT follow-up from the TARGET I trial.
    Xu B; Zhang YJ; Sun ZW; Qiao SB; Chen SL; Zhang RY; Pan DR; Pang S; Zhang Q; Xu L; Yang YJ; Leon MB; Gao RL
    Int J Cardiovasc Imaging; 2015 Dec; 31(8):1489-96. PubMed ID: 26208685
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials.
    Alsidawi S; Effat M; Rahman S; Abdallah M; Leesar M
    Cardiovasc Ther; 2015 Dec; 33(6):360-6. PubMed ID: 26363283
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A Randomized Trial Comparing the NeoVas Sirolimus-Eluting Bioresorbable Scaffold and Metallic Everolimus-Eluting Stents.
    Han Y; Xu B; Fu G; Wang X; Xu K; Jin C; Tao L; Li L; Hou Y; Su X; Fang Q; Chen L; Liu H; Wang B; Yuan Z; Gao C; Zhou S; Sun Z; Zhao Y; Guan C; Stone GW;
    JACC Cardiovasc Interv; 2018 Feb; 11(3):260-272. PubMed ID: 29413240
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Early healing assessment with optical coherence tomography of everolimus-eluting stents with bioabsorbable polymer (synergy™) at 3 and 6 months after implantation.
    de la Torre Hernández JM; Tejedor P; Camarero TG; Duran JM; Lee DH; Monedero J; Laso FS; Calderón MA; Veiga G; Zueco J
    Catheter Cardiovasc Interv; 2016 Sep; 88(3):E67-73. PubMed ID: 26526783
    [TBL] [Abstract][Full Text] [Related]  

  • 27. An optical coherence tomography study of neointimal morphology and strut coverage at different time intervals from implantation of biodegradable polymer-coated sirolimus-eluting stents.
    Legutko J; Gil RJ; Buszman PE; Kaluza GL; Mintz GS; Roleder T; Krol M; Wojdyla R; Pawlowski T; Brzezinski M; Kondys M; Skwarna B; Jakala J; Zasada W; Partyka L; Dudek D
    Catheter Cardiovasc Interv; 2018 Aug; 92(2):302-309. PubMed ID: 29027737
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound.
    Kitabata H; Loh JP; Pendyala LK; Omar A; Ota H; Minha S; Magalhaes MA; Torguson R; Chen F; Satler LF; Pichard AD; Waksman R
    Cardiovasc Revasc Med; 2014 Apr; 15(3):149-55. PubMed ID: 24767313
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Randomized comparison of acute stent malapposition between platinum-chromium versus cobalt-chromium everolimus-eluting stents.
    Kim BK; Shin DH; Kim JS; Ko YG; Choi D; Jang Y; Hong MK
    Int J Cardiovasc Imaging; 2015 Feb; 31(2):269-77. PubMed ID: 25345751
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparative assessment of three drug eluting stents with different platforms but with the same biodegradable polymer and the drug based on quantitative coronary angiography and optical coherence tomography at 12-month follow-up.
    Gil RJ; Bil J; Legutko J; Pawłowski T; Gil KE; Dudek D; Costa RA
    Int J Cardiovasc Imaging; 2018 Mar; 34(3):353-365. PubMed ID: 28965166
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Elutax paclitaxel-eluting balloon followed by bare-metal stent compared with Xience V drug-eluting stent in the treatment of de novo coronary stenosis: a randomized trial.
    Liistro F; Porto I; Angioli P; Grotti S; Ducci K; Falsini G; Bolognese L
    Am Heart J; 2013 Nov; 166(5):920-6. PubMed ID: 24176449
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Very early neointimal coverage of new biodegradable polymer drug-eluting stent compared with durable polymer everolimus-eluting stent evaluated by optical frequency domain imaging.
    Kobayashi N; Ito Y; Yamawaki M; Araki M; Sakai T; Sakamoto Y; Mori S; Tsutsumi M; Nauchi M; Honda Y; Tokuda T; Makino K; Shirai S; Hirano K
    Int J Cardiovasc Imaging; 2018 Apr; 34(4):515-522. PubMed ID: 29159531
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Neoatherosclerosis assessed with optical coherence tomography in restenotic bare metal and first- and second-generation drug-eluting stents.
    Song L; Mintz GS; Yin D; Yamamoto MH; Chin CY; Matsumura M; Fall K; Kirtane AJ; Parikh MA; Moses JW; Ali ZA; Shlofmitz RA; Maehara A
    Int J Cardiovasc Imaging; 2017 Aug; 33(8):1115-1124. PubMed ID: 28281026
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Chronic stent recoil in severely calcified coronary artery lesions. A serial optical coherence tomography study.
    Amemiya K; Maehara A; Yamamoto MH; Oyama Y; Igawa W; Ono M; Kido T; Ebara S; Okabe T; Yamashita K; Isomura N; Mintz GS; Ochiai M
    Int J Cardiovasc Imaging; 2020 Sep; 36(9):1617-1626. PubMed ID: 32462449
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Incidence and imaging outcomes of acute scaffold disruption and late structural discontinuity after implantation of the absorb Everolimus-Eluting fully bioresorbable vascular scaffold: optical coherence tomography assessment in the ABSORB cohort B Trial (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions).
    Onuma Y; Serruys PW; Muramatsu T; Nakatani S; van Geuns RJ; de Bruyne B; Dudek D; Christiansen E; Smits PC; Chevalier B; McClean D; Koolen J; Windecker S; Whitbourn R; Meredith I; Garcia-Garcia HM; Veldhof S; Rapoza R; Ormiston JA
    JACC Cardiovasc Interv; 2014 Dec; 7(12):1400-11. PubMed ID: 25523532
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Optical coherence tomographic observation of in-stent neoatherosclerosis in lesions with more than 50% neointimal area stenosis after second-generation drug-eluting stent implantation.
    Lee SY; Hur SH; Lee SG; Kim SW; Shin DH; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Hong MK
    Circ Cardiovasc Interv; 2015 Feb; 8(2):e001878. PubMed ID: 25613674
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Serial Assessment of Strut Coverage of Biodegradable Polymer Drug-Eluting Stent at 1, 2, and 3 Months After Stent Implantation by Optical Frequency Domain Imaging: The DISCOVERY 1TO3 Study (Evaluation With OFDI of Strut Coverage of Terumo New Drug Eluting Stent With Biodegradable Polymer at 1, 2, and 3 Months).
    Chevalier B; Smits PC; Carrié D; Mehilli J; Van Boven AJ; Regar E; Sawaya FJ; Chamié D; Kraaijeveld AO; Hovasse T; Vlachojannis GJ
    Circ Cardiovasc Interv; 2017 Dec; 10(12):. PubMed ID: 29246909
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Impact of late stent malapposition after drug-eluting stent implantation on long-term clinical outcomes.
    Im E; Lee SY; Hong SJ; Ahn CM; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Hong MK
    Atherosclerosis; 2019 Sep; 288():118-123. PubMed ID: 31357039
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Optical coherence tomography findings in lesions after sirolimus-eluting stent implantation with peri-stent contrast staining.
    Tada T; Kadota K; Hosogi S; Kubo S; Ozaki M; Yoshino M; Miyake K; Eguchi H; Ohashi N; Hayakawa Y; Saito N; Otsuru S; Hasegawa D; Shigemoto Y; Habara S; Imai M; Tanaka H; Fuku Y; Oka N; Kato H; Yamamoto H; Fujii S; Goto T; Mitsudo K
    Circ Cardiovasc Interv; 2012 Oct; 5(5):649-56. PubMed ID: 23011265
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation.
    Izumi D; Miyahara M; Fujimoto N; Fukuoka S; Sakai M; Dohi K; Ito M
    Heart Vessels; 2016 Aug; 31(8):1247-56. PubMed ID: 26334709
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.