These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 31366769)

  • 1. Effects of magnetic fields from electric toothbrushes on fluoride- and oral bacteria-induced corrosion of orthodontic metallic wires.
    Kameda T; Oda H; Ohkuma K; Terada K
    Dent Mater J; 2019 Dec; 38(6):909-920. PubMed ID: 31366769
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires.
    Walker MP; White RJ; Kula KS
    Am J Orthod Dentofacial Orthop; 2005 Jun; 127(6):662-9. PubMed ID: 15953890
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetic fields from electric toothbrushes promote corrosion in orthodontic stainless steel appliances but not in titanium appliances.
    Kameda T; Ohkuma K; Oda H; Sano N; Batbayar N; Terashima Y; Sato S; Terada K
    Dent Mater J; 2013; 32(6):959-69. PubMed ID: 24240898
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Exposure to the oral environment enhances the corrosion of metal orthodontic appliances caused by fluoride-containing products: Cytotoxicity, metal ion release, and surface roughness.
    Chantarawaratit PO; Yanisarapan T
    Am J Orthod Dentofacial Orthop; 2021 Jul; 160(1):101-112. PubMed ID: 33966956
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires.
    Kim H; Johnson JW
    Angle Orthod; 1999 Feb; 69(1):39-44. PubMed ID: 10022183
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Galvanic corrosion behavior of orthodontic archwire alloys coupled to bracket alloys.
    Iijima M; Endo K; Yuasa T; Ohno H; Hayashi K; Kakizaki M; Mizoguchi I
    Angle Orthod; 2006 Jul; 76(4):705-11. PubMed ID: 16808581
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microbiologically influenced corrosion of orthodontic metallic appliances.
    Kameda T; Oda H; Ohkuma K; Sano N; Batbayar N; Terashima Y; Sato S; Terada K
    Dent Mater J; 2014; 33(2):187-95. PubMed ID: 24583645
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of pH, fluoride and tribocorrosion on the surface properties of dental archwires.
    Močnik P; Kosec T; Kovač J; Bizjak M
    Mater Sci Eng C Mater Biol Appl; 2017 Sep; 78():682-689. PubMed ID: 28576038
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Variations in surface characteristics and corrosion behaviour of metal brackets and wires in different electrolyte solutions.
    Kao CT; Huang TH
    Eur J Orthod; 2010 Oct; 32(5):555-60. PubMed ID: 20139132
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of intraoral application of antiseptics and fluorides during orthodontic treatment on corrosion and mechanical characteristics of nickel-titanium alloy in orthodontic appliances.
    Belasic TZ; Pejova B; Curkovic HO; Kamenar E; Cetenovic B; Spalj S
    Angle Orthod; 2021 Jul; 91(4):528-537. PubMed ID: 33566077
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of corrosion resistance and surface characteristics of orthodontic wires immersed in different mouthwashes.
    Nalbantgil D; Ulkur F; Kardas G; Culha M
    Biomed Mater Eng; 2016 Nov; 27(5):539-549. PubMed ID: 27886000
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Corrosion resistance and mechanical properties of titanium nitride plating on orthodontic wires.
    Sugisawa H; Kitaura H; Ueda K; Kimura K; Ishida M; Ochi Y; Kishikawa A; Ogawa S; Takano-Yamamoto T
    Dent Mater J; 2018 Mar; 37(2):286-292. PubMed ID: 29109336
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Corrosion resistance of NiTi in fluoride and acid environments.
    Benyahia H; Ebntouhami M; Forsal I; Zaoui F; Aalloula E
    Int Orthod; 2009 Dec; 7(4):322-34. PubMed ID: 20303919
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Surface changes induced by fluoride prophylactic agents on titanium-based orthodontic wires.
    Watanabe I; Watanabe E
    Am J Orthod Dentofacial Orthop; 2003 Jun; 123(6):653-6. PubMed ID: 12806345
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vitro corrosion characteristics of commercially available orthodontic wires.
    Yonekura Y; Endo K; Iijima M; Ohno H; Mizoguchi I
    Dent Mater J; 2004 Jun; 23(2):197-202. PubMed ID: 15287568
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of fluoride mouth rinses on various orthodontic archwire alloys tested by modified bending test: an in vitro study.
    Srivastava K; Chandra PK; Kamat N
    Indian J Dent Res; 2012; 23(3):433-4. PubMed ID: 23059594
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Localized corrosion behaviour in simulated human body fluids of commercial Ni-Ti orthodontic wires.
    Rondelli G; Vicentini B
    Biomaterials; 1999 Apr; 20(8):785-92. PubMed ID: 10353661
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of topographical features on the fluoride corrosion of Ni-Ti orthodontic archwires.
    Abalos C; Paúl A; Mendoza A; Solano E; Gil FJ
    J Mater Sci Mater Med; 2011 Dec; 22(12):2813-21. PubMed ID: 22042458
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An investigation into the effects of polishing on surface hardness and corrosion of orthodontic archwires.
    Hunt NP; Cunningham SJ; Golden CG; Sheriff M
    Angle Orthod; 1999 Oct; 69(5):433-40. PubMed ID: 10515141
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Corrosion behavior of shape memory, superelastic, and nonsuperelastic nickel-titanium-based orthodontic wires at various temperatures.
    Pun DK; Berzins DW
    Dent Mater; 2008 Feb; 24(2):221-7. PubMed ID: 17624421
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.