BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

646 related articles for article (PubMed ID: 31367161)

  • 1. Quantitative diffusion-weighted magnetic resonance enterography in ileal Crohn's disease: A systematic analysis of intra and interobserver reproducibility.
    Yu H; Shen YQ; Tan FQ; Zhou ZL; Li Z; Hu DY; Morelli JN
    World J Gastroenterol; 2019 Jul; 25(27):3619-3633. PubMed ID: 31367161
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diffusion-weighted MRI Enables to Accurately Grade Inflammatory Activity in Patients of Ileocolonic Crohn's Disease: Results from an Observational Study.
    Li XH; Sun CH; Mao R; Huang SY; Zhang ZW; Yang XF; Huang L; Lin JJ; Zhang J; Ben-Horin S; Feng ST; Chen MH; Li ZP
    Inflamm Bowel Dis; 2017 Feb; 23(2):244-253. PubMed ID: 28079618
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prospective comparison of diffusion-weighted magnetic resonance enterography and contrast enhanced computed tomography enterography for the detection of ileocolonic Crohn's disease.
    Yu H; Wang Y; Wang Z; Li J; Lu J; Hu D
    J Gastroenterol Hepatol; 2020 Jul; 35(7):1136-1142. PubMed ID: 31785602
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dynamic contrast-enhanced magnetic resonance imaging and diffusion-weighted imaging in the activity staging of terminal ileum Crohn's disease.
    Wu YC; Xiao ZB; Lin XH; Zheng XY; Cao DR; Zhang ZS
    World J Gastroenterol; 2020 Oct; 26(39):6057-6073. PubMed ID: 33132655
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of Activity of Crohn Disease by Diffusion-Weighted Magnetic Resonance Imaging.
    Li XH; Sun CH; Mao R; Zhang ZW; Jiang XS; Pui MH; Chen MH; Li ZP
    Medicine (Baltimore); 2015 Oct; 94(43):e1819. PubMed ID: 26512584
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intravoxel incoherent motion diffusion-weighted imaging in quantitative evaluation of Ileal Crohn's disease - A comparison with dynamic contrast-enhanced magnetic resonance imaging and ileocolonoscopy.
    Sun P; Zhu D; Li J; Zhang J; Zeng M; Fang L; Ruan J; Zhao X; Shi Y; Wang S; Zhao B
    Magn Reson Imaging; 2023 Apr; 97():82-90. PubMed ID: 36608907
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diffusion-weighted magnetic resonance imaging in ileocolonic Crohn's disease: validation of quantitative index of activity.
    Hordonneau C; Buisson A; Scanzi J; Goutorbe F; Pereira B; Borderon C; Da Ines D; Montoriol PF; Garcier JM; Boyer L; Bommelaer G; Petitcolin V
    Am J Gastroenterol; 2014 Jan; 109(1):89-98. PubMed ID: 24247212
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diffusion-weighted MR enterography for evaluating Crohn's disease: how does it add diagnostically to conventional MR enterography?
    Kim KJ; Lee Y; Park SH; Kang BK; Seo N; Yang SK; Ye BD; Park SH; Kim SY; Baek S; Ha HK
    Inflamm Bowel Dis; 2015 Jan; 21(1):101-9. PubMed ID: 25358063
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Apparent diffusion coefficient and enhancement patterns in MR imaging as markers of severe or moderate ileum inflammation in Crohn's disease.
    Faletti R; Ribaldone DG; Gatti M; Perazzini C; Robella M; Angelino F; Saracco GM; Astegiano M; Pellicano R; Fonio P
    Rev Esp Enferm Dig; 2019 Jan; 111(1):28-33. PubMed ID: 30284909
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diffusion-weighted magnetic resonance imaging for detecting and assessing ileal inflammation in Crohn's disease.
    Buisson A; Joubert A; Montoriol PF; Da Ines D; Hordonneau C; Pereira B; Garcier JM; Bommelaer G; Petitcolin V
    Aliment Pharmacol Ther; 2013 Mar; 37(5):537-45. PubMed ID: 23289713
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of the simplified magnetic resonance index of activity by using DWI without gadolinium enhancement to evaluate bowel inflammation in Crohn's disease.
    Bae H; Seo N; Kang EA; Cheon JH; Lim JS; Kim MJ
    Eur Radiol; 2023 May; 33(5):3266-3275. PubMed ID: 36899087
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Magnetic resonance enterography has good inter-rater agreement and diagnostic accuracy for detecting inflammation in pediatric Crohn disease.
    Church PC; Greer MC; Cytter-Kuint R; Doria AS; Griffiths AM; Turner D; Walters TD; Feldman BM
    Pediatr Radiol; 2017 May; 47(5):565-575. PubMed ID: 28283726
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Diffusion-weighted imaging in quiescent Crohn's disease: correlation with inflammatory biomarkers and video capsule endoscopy.
    Klang E; Kopylov U; Eliakim R; Rozendorn N; Yablecovitch D; Lahat A; Ben-Horin S; Amitai MM
    Clin Radiol; 2017 Sep; 72(9):798.e7-798.e13. PubMed ID: 28506799
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Utility of the diffusion-weighted imaging for activity evaluation in Crohn's disease patients underwent magnetic resonance enterography.
    Qi F; Jun S; Qi QY; Chen PJ; Chuan GX; Jiong Z; Rong XJ
    BMC Gastroenterol; 2015 Feb; 15():12. PubMed ID: 25653007
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of patency capsule retention using MR diffusion-weighted imaging.
    Klang E; Kopylov U; Ben-Horin S; Lahat A; Yablecovitch D; Rozendorn N; Eliakim R; Amitai MM
    Eur Radiol; 2017 Dec; 27(12):4979-4985. PubMed ID: 28677060
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Diffusion-weighted MRI of breast lesions: a prospective clinical investigation of the quantitative imaging biomarker characteristics of reproducibility, repeatability, and diagnostic accuracy.
    Spick C; Bickel H; Pinker K; Bernathova M; Kapetas P; Woitek R; Clauser P; Polanec SH; Rudas M; Bartsch R; Helbich TH; Baltzer PA
    NMR Biomed; 2016 Oct; 29(10):1445-53. PubMed ID: 27553252
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diffusion kurtosis MRI versus conventional diffusion-weighted imaging for evaluating inflammatory activity in Crohn's disease.
    Huang L; Li XH; Huang SY; Zhang ZW; Yang XF; Lin JJ; Jiang MJ; Feng ST; Sun CH; Li ZP
    J Magn Reson Imaging; 2018 Mar; 47(3):702-709. PubMed ID: 28577319
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preoperative evaluation of small bowel complications in Crohn's disease: comparison of diffusion-weighted and contrast-enhanced MR imaging.
    Barat M; Hoeffel C; Bouquot M; Jannot AS; Dautry R; Boudiaf M; Pautrat K; Kaci R; Camus M; Eveno C; Pocard M; Soyer P; Dohan A
    Eur Radiol; 2019 Apr; 29(4):2034-2044. PubMed ID: 30302591
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intravoxel incoherent motion diffusion-weighted magnetic resonance imaging for predicting histological grade of hepatocellular carcinoma: Comparison with conventional diffusion-weighted imaging.
    Zhu SC; Liu YH; Wei Y; Li LL; Dou SW; Sun TY; Shi DP
    World J Gastroenterol; 2018 Feb; 24(8):929-940. PubMed ID: 29491686
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diffusion-weighted imaging for evaluating inflammatory activity in Crohn's disease: comparison with histopathology, conventional MRI activity scores, and faecal calprotectin.
    Pendsé DA; Makanyanga JC; Plumb AA; Bhatnagar G; Atkinson D; Rodriguez-Justo M; Halligan S; Taylor SA
    Abdom Radiol (NY); 2017 Jan; 42(1):115-123. PubMed ID: 27567607
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 33.