These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 31371158)

  • 21. The contact area of the radiocapitellar joint under pronation and supination with axial load using a 3-dimensional computed tomography: an in vivo study.
    Bian H; Kim H; Kholinne E; Sun Y; Kwak JM; Tan J
    J Shoulder Elbow Surg; 2021 Jun; 30(6):1238-1244. PubMed ID: 32950672
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Radial head replacement with a bipolar system: an average 10-year follow-up.
    Sershon RA; Luchetti TJ; Cohen MS; Wysocki RW
    J Shoulder Elbow Surg; 2018 Feb; 27(2):e38-e44. PubMed ID: 29128376
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Cemented bipolar radial head arthroplasty: midterm follow-up results.
    Heijink A; Kodde IF; Mulder PGH; Van Dijk CN; Eygendaal D
    J Shoulder Elbow Surg; 2016 Nov; 25(11):1829-1838. PubMed ID: 27521138
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Contribution of monoblock and bipolar radial head prostheses to valgus stability of the elbow.
    Pomianowski S; Morrey BF; Neale PG; Park MJ; O'Driscoll SW; An KN
    J Bone Joint Surg Am; 2001 Dec; 83(12):1829-34. PubMed ID: 11741062
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The load transfer effect of monopolar and bipolar radial head prosthesis designs on capitellar cartilage: A comparative biomechanical cadaver study.
    Aşık MO; Akdemir M; Turgut N; Ünal AM; Özkan M; Ekin A
    Acta Orthop Traumatol Turc; 2022 Jan; 56(1):58-63. PubMed ID: 35234131
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Forearm and elbow injury: the influence of rotational position.
    McGinley JC; Hopgood BC; Gaughan JP; Sadeghipour K; Kozin SH
    J Bone Joint Surg Am; 2003 Dec; 85(12):2403-9. PubMed ID: 14668511
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Radiocapitellar contact characteristics during prosthetic radial head subluxation.
    Sahu D; Fitzsimmons JS; Thoreson AR; An KN; O'Driscoll SW
    J Shoulder Elbow Surg; 2017 Jan; 26(1):170-177. PubMed ID: 27727059
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The effect of prosthetic radial head geometry on the distribution and magnitude of radiocapitellar joint contact pressures.
    Bachman DR; Thaveepunsan S; Park S; Fitzsimmons JS; An KN; O'Driscoll SW
    J Hand Surg Am; 2015 Feb; 40(2):281-8. PubMed ID: 25542439
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Axial load transmission through the elbow during forearm rotation.
    Hwang JT; Kim Y; Bachman DR; Shields MN; Berglund LJ; Fitzsimmons AT; Fitzsimmons JS; O'Driscoll SW
    J Shoulder Elbow Surg; 2018 Mar; 27(3):530-537. PubMed ID: 29290603
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The effect of hemiarthroplasty implant modulus on contact mechanics: an experimental investigation.
    Berkmortel CJ; Szmit J; Langohr GD; King GJW; Johnson JA
    J Shoulder Elbow Surg; 2021 Dec; 30(12):2845-2851. PubMed ID: 34293420
    [TBL] [Abstract][Full Text] [Related]  

  • 31. In vivo three-dimensional elbow biomechanics during forearm rotation.
    Omori S; Miyake J; Oka K; Tanaka H; Yoshikawa H; Murase T
    J Shoulder Elbow Surg; 2016 Jan; 25(1):112-9. PubMed ID: 26422527
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Radiocapitellar joint contacts after bipolar radial head arthroplasty.
    Moungondo F; El Kazzi W; van Riet R; Feipel V; Rooze M; Schuind F
    J Shoulder Elbow Surg; 2010 Mar; 19(2):230-5. PubMed ID: 20036580
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Downsizing effect of a modular radial head prosthesis on the lateral collateral ligament of the elbow: A cadaveric study.
    Hatta T; Shinagawa K; Kawakami J; Yamamoto N; Kitada M; Itoi E
    Clin Biomech (Bristol, Avon); 2020 Dec; 80():105140. PubMed ID: 32745705
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Loose-fitting radial head prosthesis replacement for treatment of comminuted fracture of the radial head.
    Hao W; Cheng L; Ming C
    Minerva Chir; 2017 Feb; 72(1):31-35. PubMed ID: 27456265
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The impact of capitellar arthroplasty on elbow contact mechanics: Implications for implant design.
    Sabo MT; Shannon H; Ng J; Ferreira LM; Johnson JA; King GJ
    Clin Biomech (Bristol, Avon); 2011 Jun; 26(5):458-63. PubMed ID: 21474220
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effect of radiocapitellar Achilles disc arthroplasty on coronoid and capitellar contact pressures after radial head excision.
    Ramazanian T; Müller-Lebschi JA; Chuang MY; Vaichinger AM; Fitzsimmons JS; O'Driscoll SW
    J Shoulder Elbow Surg; 2018 Oct; 27(10):1785-1791. PubMed ID: 30007821
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Contact mechanics of reverse engineered distal humeral hemiarthroplasty implants.
    Willing R; King GJW; Johnson JA
    J Biomech; 2015 Nov; 48(15):4037-4042. PubMed ID: 26493347
    [TBL] [Abstract][Full Text] [Related]  

  • 38. In vitro assessment of the contact mechanics of reverse-engineered distal humeral hemiarthroplasty prostheses.
    Willing R; Lapner M; King GJ; Johnson JA
    Clin Biomech (Bristol, Avon); 2014 Nov; 29(9):990-6. PubMed ID: 25238687
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow.
    Van Glabbeek F; Van Riet RP; Baumfeld JA; Neale PG; O'Driscoll SW; Morrey BF; An KN
    J Bone Joint Surg Am; 2004 Dec; 86(12):2629-35. PubMed ID: 15590846
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The Effect of Radial Head Hemiarthroplasty Geometry on Proximal Radioulnar Joint Contact Mechanics.
    Langohr GD; Willing R; Medley JB; King GJ; Johnson JA
    J Hand Surg Am; 2016 Jul; 41(7):745-52. PubMed ID: 27241850
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.