  • 1. Evaluation of a novel flow-controlled syringe infusion pump for precise and continuous drug delivery at low flow rates: a laboratory study.
    Batliner M; Weiss M; Dual SA; Grass B; Meboldt M; Schmid Daners M
    Anaesthesia; 2019 Nov; 74(11):1425-1431. PubMed ID: 31373391
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Performance of modern syringe infusion pump assemblies at low infusion rates in the perioperative setting.
    Baeckert M; Batliner M; Grass B; Buehler PK; Daners MS; Meboldt M; Weiss M
    Br J Anaesth; 2020 Feb; 124(2):173-182. PubMed ID: 31864721
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In-line filter included into the syringe infusion pump assembly reduces flow irregularities.
    Brotschi B; Grass B; Weiss M; Doell C; Bernet V
    Intensive Care Med; 2012 Mar; 38(3):518-22. PubMed ID: 22237747
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accurate continuous drug delivery at low infusion rate with a novel microvolumetric infusion pump (MVIP): pump design, evaluation and comparison to the current standard.
    Weiss M; Gerber S; Füchslin RM; Neff TA
    Anaesthesia; 2004 Nov; 59(11):1133-7. PubMed ID: 15479325
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps.
    Neff SB; Neff TA; Gerber S; Weiss MM
    Eur J Anaesthesiol; 2007 Jul; 24(7):602-8. PubMed ID: 17261217
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of syringe size on the performance of infusion pumps at low flow rates.
    Schmidt N; Saez C; Seri I; Maturana A
    Pediatr Crit Care Med; 2010 Mar; 11(2):282-6. PubMed ID: 19935442
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An analysis of drug delivery dynamics via a pediatric central venous infusion system: quantification of delays in achieving intended doses.
    Bartels K; Moss DR; Peterfreund RA
    Anesth Analg; 2009 Oct; 109(4):1156-61. PubMed ID: 19762743
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Do antisiphon valves reduce flow irregularities during vertical displacement of infusion pump systems?
    Weiss M; Fischer J; Neff T; Schulz G; Bänziger O
    Anaesth Intensive Care; 2000 Dec; 28(6):680-3. PubMed ID: 11153297
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Start-up delays of infusion syringe pumps.
    Neff T; Fischer J; Fehr S; Baenziger O; Weiss M
    Paediatr Anaesth; 2001; 11(5):561-5. PubMed ID: 11696120
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simulation Analysis of Flow Rate Variability During Microinfusions: The Effect of Vertical Displacement and Multidrug Infusion in Conventional Infusion Pumps Versus New Cylinder-Type Infusion Pumps.
    Oh EJ; Hong KY; Lee JH; Kim DK; Cho J; Min JJ
    Anesth Analg; 2022 Jan; 134(1):59-68. PubMed ID: 34517393
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lag times to steady state drug delivery by continuous intravenous infusion: direct comparison of peristaltic and syringe pump performance identifies contributions from infusion system dead volume and pump startup characteristics.
    Gibson LE; Knudsen AS; Arney D; Deng H; Sims NM; Peterfreund RA
    J Clin Monit Comput; 2022 Oct; 36(5):1489-1498. PubMed ID: 34878612
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Syringe Pump Performance Maintained with IV Filter Use During Low Flow Rate Delivery for Pediatric Patients.
    Chau DF; Vasilopoulos T; Schoepf M; Zhang C; Fahy BG
    Anesth Analg; 2016 Sep; 123(3):705-14. PubMed ID: 27074895
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Disturbance of continuous, pump administration of cardiovascular drugs by hydrostatic pressure].
    Krauskopf KH; Rauscher J; Brandt L
    Anaesthesist; 1996 May; 45(5):449-52. PubMed ID: 8779404
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An in vitro evaluation of infusion methods using a syringe pump to improve noradrenaline administration.
    Genay S; Décaudin B; Scoccia S; Barthélémy C; Debaene B; Lebuffe G; Odou P
    Acta Anaesthesiol Scand; 2015 Feb; 59(2):197-204. PubMed ID: 25476454
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Panomat P-10 micro-volumetric infusion pump is suitable for continuous drug administration at minimal flow rates.
    Neff TA; Fellmann C; Fuechslin RM; Gerber AC; Weiss M
    Can J Anaesth; 2002 Dec; 49(10):1048-52. PubMed ID: 12477676
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [[The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems] ].
    Schulz G; Fischer J; Neff T; Bänziger O; Weiss M
    Anaesthesist; 2000 Dec; 49(12):1018-23. PubMed ID: 11202074
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Infusion pump delivers over-dosage of propofol as a result of missing syringe support.
    Koch C; Hollister C; Breen PH
    Anesth Analg; 2006 Apr; 102(4):1154-6. PubMed ID: 16551915
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Syringe size and flow rate affect drug delivery from syringe pumps.
    Weiss M; Hug MI; Neff T; Fischer J
    Can J Anaesth; 2000 Oct; 47(10):1031-5. PubMed ID: 11032282
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Ohmeda 9000 syringe pump. The first of a new generation of syringe drivers.
    Stokes DN; Peacock JE; Lewis R; Hutton P
    Anaesthesia; 1990 Dec; 45(12):1062-6. PubMed ID: 2278331
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Factors altering low-flow drug delivery using syringe pumps: Consequences on vasoactive drug infusion in preterm infant].
    Rakza T; Richard A; Lelieur AC; Villaume I; Huyghe A; Nempont C; Storme L
    Arch Pediatr; 2005 May; 12(5):548-54. PubMed ID: 15885544
    [TBL] [Abstract][Full Text] [Related]  