202 related articles for article (PubMed ID: 31374092)
1. Robotic middle ear access for cochlear implantation: First in man.
Caversaccio M; Wimmer W; Anso J; Mantokoudis G; Gerber N; Rathgeb C; Schneider D; Hermann J; Wagner F; Scheidegger O; Huth M; Anschuetz L; Kompis M; Williamson T; Bell B; Gavaghan K; Weber S
PLoS One; 2019; 14(8):e0220543. PubMed ID: 31374092
[TBL] [Abstract][Full Text] [Related]
2. In vitro accuracy evaluation of image-guided robot system for direct cochlear access.
Bell B; Gerber N; Williamson T; Gavaghan K; Wimmer W; Caversaccio M; Weber S
Otol Neurotol; 2013 Sep; 34(7):1284-90. PubMed ID: 23921934
[TBL] [Abstract][Full Text] [Related]
3. Robotic cochlear implantation: feasibility of a multiport approach in an ex vivo model.
Schneider D; Stenin I; Ansó J; Hermann J; Mueller F; Pereira Bom Braga G; Rathgeb C; Wimmer W; Schipper J; Kristin J; Caversaccio M; Anschuetz L; Weber S; Klenzner T
Eur Arch Otorhinolaryngol; 2019 May; 276(5):1283-1289. PubMed ID: 30739180
[TBL] [Abstract][Full Text] [Related]
4. Robotic cochlear implantation in post-meningitis ossified cochlea.
Al Saadi M; Heuninck E; De Raeve L; Van de Heyning P; Topsakal V
Am J Otolaryngol; 2023; 44(1):103668. PubMed ID: 36323158
[TBL] [Abstract][Full Text] [Related]
5. True keyhole cochlear implant surgery.
Abari J; Heuninck E; Al Saadi M; Topsakal V
Am J Otolaryngol; 2023; 44(4):103926. PubMed ID: 37229977
[TBL] [Abstract][Full Text] [Related]
6. Robotic cochlear implantation: surgical procedure and first clinical experience.
Caversaccio M; Gavaghan K; Wimmer W; Williamson T; Ansò J; Mantokoudis G; Gerber N; Rathgeb C; Feldmann A; Wagner F; Scheidegger O; Kompis M; Weisstanner C; Zoka-Assadi M; Roesler K; Anschuetz L; Huth M; Weber S
Acta Otolaryngol; 2017 Apr; 137(4):447-454. PubMed ID: 28145157
[TBL] [Abstract][Full Text] [Related]
7. Comparison of the Surgical Techniques and Robotic Techniques for Cochlear Implantation in Terms of the Trajectories Toward the Inner Ear.
Topsakal V; Matulic M; Assadi MZ; Mertens G; Rompaey VV; Van de Heyning P
J Int Adv Otol; 2020 Apr; 16(1):3-7. PubMed ID: 32209514
[TBL] [Abstract][Full Text] [Related]
8. Population Statistics Approach for Safety Assessment in Robotic Cochlear Implantation.
Williamson T; Gavaghan K; Gerber N; Weder S; Anschuetz L; Wagner F; Weisstanner C; Mantokoudis G; Caversaccio M; Weber S
Otol Neurotol; 2017 Jun; 38(5):759-764. PubMed ID: 28196000
[TBL] [Abstract][Full Text] [Related]
9. Clinical validation study of percutaneous cochlear access using patient-customized microstereotactic frames.
Labadie RF; Balachandran R; Mitchell JE; Noble JH; Majdani O; Haynes DS; Bennett ML; Dawant BM; Fitzpatrick JM
Otol Neurotol; 2010 Jan; 31(1):94-9. PubMed ID: 20019561
[TBL] [Abstract][Full Text] [Related]
10. Implantation of the completely ossified cochlea: an image-guided approach.
Wanna GB; Carlson ML; Blachon GS; Noble JH; Dawant BM; Labadie RF; Balachandran R
Otol Neurotol; 2013 Apr; 34(3):522-5. PubMed ID: 23370556
[TBL] [Abstract][Full Text] [Related]
11. Robotic Cochlear Implantation for Direct Cochlear Access.
Caversaccio M; Mantokoudis G; Wagner F; Aebischer P; Weder S; Wimmer W
J Vis Exp; 2022 Jun; (184):. PubMed ID: 35786698
[TBL] [Abstract][Full Text] [Related]
12. Image-Based Planning of Minimally Traumatic Inner Ear Access for Robotic Cochlear Implantation.
Mueller F; Hermann J; Weber S; O'Toole Bom Braga G; Topsakal V
Front Surg; 2021; 8():761217. PubMed ID: 34901143
[No Abstract] [Full Text] [Related]
13. Improved auditory performance of cochlear implant patients using the middle fossa approach.
Colletti V; Fiorino FG; Saccetto L; Giarbini N; Carner M
Audiology; 1999; 38(4):225-34. PubMed ID: 10431908
[TBL] [Abstract][Full Text] [Related]
14. Feasibility of Pediatric Robotic Cochlear Implantation in Phantoms.
Bom Braga GO; Schneider D; Muller F; Hermann J; Weber S; Caversaccio M
Otol Neurotol; 2020 Feb; 41(2):e192-e200. PubMed ID: 31789802
[TBL] [Abstract][Full Text] [Related]
15. The round window: is it the "cochleostomy" of choice? Experience in 130 consecutive cochlear implants.
Gudis DA; Montes M; Bigelow DC; Ruckenstein MJ
Otol Neurotol; 2012 Dec; 33(9):1497-501. PubMed ID: 22972422
[TBL] [Abstract][Full Text] [Related]
16. First Study in Men Evaluating a Surgical Robotic Tool Providing Autonomous Inner Ear Access for Cochlear Implantation.
Topsakal V; Heuninck E; Matulic M; Tekin AM; Mertens G; Van Rompaey V; Galeazzi P; Zoka-Assadi M; van de Heyning P
Front Neurol; 2022; 13():804507. PubMed ID: 35386404
[TBL] [Abstract][Full Text] [Related]
17. Feasibility of using EMG for early detection of the facial nerve during robotic direct cochlear access.
Ansó J; Stahl C; Gerber N; Williamson T; Gavaghan K; Rösler KM; Caversaccio MD; Weber S; Bell B
Otol Neurotol; 2014 Mar; 35(3):545-54. PubMed ID: 24492132
[TBL] [Abstract][Full Text] [Related]
18. The accuracy of image-based safety analysis for robotic cochlear implantation.
Rathgeb C; Wagner F; Wimmer W; Gerber N; Williamson T; Anschütz L; Weder S; Stadelmann M; Braga G; Anso J; Caversaccio M; Weber S; Gavaghan K
Int J Comput Assist Radiol Surg; 2019 Jan; 14(1):83-92. PubMed ID: 30073453
[TBL] [Abstract][Full Text] [Related]
19. Cochlear implantation: is hearing preservation necessary in severe to profound hearing loss?
Derinsu U; Serin GM; Akdaş F; Batman Ç
J Craniofac Surg; 2011 Mar; 22(2):520-2. PubMed ID: 21403538
[TBL] [Abstract][Full Text] [Related]
20. Robotics, automation, active electrode arrays, and new devices for cochlear implantation: A contemporary review.
De Seta D; Daoudi H; Torres R; Ferrary E; Sterkers O; Nguyen Y
Hear Res; 2022 Feb; 414():108425. PubMed ID: 34979455
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]