BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

397 related articles for article (PubMed ID: 31382253)

  • 1. Depth-of-interaction study of a dual-readout detector based on TOFPET2 application-specific integrated circuit.
    Li M; Abbaszadeh S
    Phys Med Biol; 2019 Sep; 64(17):175008. PubMed ID: 31382253
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.
    Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and initial characterization of a high-resolution PET detector module with DOI.
    Li M; Wang Y; Abbaszadeh S
    Biomed Phys Eng Express; 2020 Nov; 6(6):. PubMed ID: 34234961
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance evaluation of a staggered three-layer DOI PET detector using a 1 mm LYSO pitch with PETsys TOFPET2 ASIC: comparison of HAMAMATSU and KETEK SiPMs.
    Binder T; Kang HG; Nitta M; Schneider F; Yamaya T; Parodi K; Wiest F; Thirolf PG
    Phys Med Biol; 2021 Jun; 66(12):. PubMed ID: 33906179
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout.
    Seo M; Park H; Lee S; Ko GB; Lee JS
    Med Phys; 2023 Jul; 50(7):4112-4121. PubMed ID: 36907664
    [TBL] [Abstract][Full Text] [Related]  

  • 6. SiPM signal readout for inter-crystal scatter event identification in PET detectors.
    Park H; Lee JS
    Phys Med Biol; 2020 Oct; 65(20):205010. PubMed ID: 32702670
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance of long rectangular semi-monolithic scintillator PET detectors.
    Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Crystal surface and reflector optimization for the SiPM-based dual-ended readout TOF-DOI PET detector.
    Kang HG; Yamaya T; Han YB; Song SH; Ko GB; Lee JS; Hong SJ
    Biomed Phys Eng Express; 2020 Nov; 6(6):. PubMed ID: 34035192
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout.
    Ren S; Yang Y; Cherry SR
    Med Phys; 2014 Jul; 41(7):072503. PubMed ID: 24989406
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of a high-resolution depth encoding PET detector using barium sulfate reflector.
    Kuang Z; Wang X; Li C; Deng X; Feng K; Hu Z; Fu X; Ren N; Zhang X; Zheng Y; Liang D; Liu X; Zheng H; Yang Y
    Phys Med Biol; 2017 Jul; 62(15):5945-5958. PubMed ID: 28682792
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance comparison of dual-ended readout depth-encoding PET detectors based on BGO and LYSO crystals.
    Du J; Ariño-Estrada G; Bai X; Cherry SR
    Phys Med Biol; 2020 Nov; 65(23):. PubMed ID: 33086214
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 16-channel SiPM high-frequency readout with time-over-threshold discrimination for ultrafast time-of-flight applications.
    Nadig V; Hornisch M; Oehm J; Herweg K; Schulz V; Gundacker S
    EJNMMI Phys; 2023 Dec; 10(1):76. PubMed ID: 38044383
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of capacitive multiplexing circuit for SiPM-based time-of-flight (TOF) PET detector.
    Choe HJ; Choi Y; Hu W; Yan J; Ho Jung J
    Phys Med Biol; 2017 Apr; 62(7):N120-N133. PubMed ID: 28263947
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultra-high-resolution depth-encoding small animal PET detectors: Using GAGG and LYSO crystal arrays.
    Niu M; Liu Z; Kuang Z; Wang X; Ren N; Sang Z; Wu S; Cong L; Sun T; Hu Z; Yang Y
    Med Phys; 2022 May; 49(5):3006-3020. PubMed ID: 35301730
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High resolution detectors for whole-body PET scanners by using dual-ended readout.
    Liu Z; Niu M; Kuang Z; Ren N; Wu S; Cong L; Wang X; Sang Z; Williams C; Yang Y
    EJNMMI Phys; 2022 Apr; 9(1):29. PubMed ID: 35445890
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A depth encoding PET detector using four-crystals-to-one-SiPM coupling and light-sharing window method.
    Zhang X; Xie S; Yang J; Weng F; Xu J; Huang Q; Peng Q
    Med Phys; 2019 Aug; 46(8):3385-3398. PubMed ID: 31107969
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A thick semi-monolithic scintillator detector for clinical PET scanners.
    Zhang C; Wang X; Sun M; Kuang Z; Zhang X; Ren N; Wu S; Sang Z; Sun T; Hu Z; Yang Y; Liu Z
    Phys Med Biol; 2021 Mar; 66(6):065023. PubMed ID: 33709958
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An edge-readout, multilayer detector for positron emission tomography.
    Li X; Ruiz-Gonzalez M; Furenlid LR
    Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Interleaved signal multiplexing readout in depth encoding Prism-PET detectors.
    Li Y; LaBella A; Zeng X; Wang Z; Petersen E; Cao X; Zhao W; Goldan AH
    Med Phys; 2023 Jul; 50(7):4234-4243. PubMed ID: 37191309
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-Resolution Depth-Encoding PET Detector Module with Prismatoid Light-Guide Array.
    LaBella A; Cao X; Petersen E; Lubinsky R; Biegon A; Zhao W; Goldan AH
    J Nucl Med; 2020 Oct; 61(10):1528-1533. PubMed ID: 32111684
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.