These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 31395867)

  • 1. Noncanonical mechanism of voltage sensor coupling to pore revealed by tandem dimers of Shaker.
    Carvalho-de-Souza JL; Bezanilla F
    Nat Commun; 2019 Aug; 10(1):3584. PubMed ID: 31395867
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The isolated voltage sensing domain of the Shaker potassium channel forms a voltage-gated cation channel.
    Zhao J; Blunck R
    Elife; 2016 Oct; 5():. PubMed ID: 27710769
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mode shift of the voltage sensors in Shaker K+ channels is caused by energetic coupling to the pore domain.
    Haddad GA; Blunck R
    J Gen Physiol; 2011 May; 137(5):455-72. PubMed ID: 21518834
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Molecular basis for functional connectivity between the voltage sensor and the selectivity filter gate in
    Bassetto CA; Carvalho-de-Souza JL; Bezanilla F
    Elife; 2021 Feb; 10():. PubMed ID: 33620313
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reciprocal voltage sensor-to-pore coupling leads to potassium channel C-type inactivation.
    Conti L; Renhorn J; Gabrielsson A; Turesson F; Liin SI; Lindahl E; Elinder F
    Sci Rep; 2016 Jun; 6():27562. PubMed ID: 27278891
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Voltage-insensitive gating after charge-neutralizing mutations in the S4 segment of Shaker channels.
    Bao H; Hakeem A; Henteleff M; Starkus JG; Rayner MD
    J Gen Physiol; 1999 Jan; 113(1):139-51. PubMed ID: 9874694
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Inter-subunit interactions across the upper voltage sensing-pore domain interface contribute to the concerted pore opening transition of Kv channels.
    Shem-Ad T; Irit O; Yifrach O
    PLoS One; 2013; 8(12):e82253. PubMed ID: 24340010
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Voltage sensitivity and gating charge in Shaker and Shab family potassium channels.
    Islas LD; Sigworth FJ
    J Gen Physiol; 1999 Nov; 114(5):723-42. PubMed ID: 10539976
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An intersubunit interaction between S4-S5 linker and S6 is responsible for the slow off-gating component in Shaker K+ channels.
    Batulan Z; Haddad GA; Blunck R
    J Biol Chem; 2010 Apr; 285(18):14005-19. PubMed ID: 20202932
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The EAG Voltage-Dependent K
    Barros F; de la Peña P; Domínguez P; Sierra LM; Pardo LA
    Front Pharmacol; 2020; 11():411. PubMed ID: 32351384
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Functional interactions at the interface between voltage-sensing and pore domains in the Shaker K(v) channel.
    Soler-Llavina GJ; Chang TH; Swartz KJ
    Neuron; 2006 Nov; 52(4):623-34. PubMed ID: 17114047
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Coupling between voltage sensors and activation gate in voltage-gated K+ channels.
    Lu Z; Klem AM; Ramu Y
    J Gen Physiol; 2002 Nov; 120(5):663-76. PubMed ID: 12407078
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The twisted ion-permeation pathway of a resting voltage-sensing domain.
    Tombola F; Pathak MM; Gorostiza P; Isacoff EY
    Nature; 2007 Feb; 445(7127):546-9. PubMed ID: 17187057
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Helical motion of an S4 voltage sensor revealed by gating pore currents.
    Catterall WA; Yarov-Yarovoy V
    Channels (Austin); 2010; 4(2):75-7. PubMed ID: 20139706
    [TBL] [Abstract][Full Text] [Related]  

  • 15. S4-S5 linker movement during activation and inactivation in voltage-gated K
    Kalstrup T; Blunck R
    Proc Natl Acad Sci U S A; 2018 Jul; 115(29):E6751-E6759. PubMed ID: 29959207
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Nonsensing residues in S3-S4 linker's C terminus affect the voltage sensor set point in K
    Carvalho-de-Souza JL; Bezanilla F
    J Gen Physiol; 2018 Feb; 150(2):307-321. PubMed ID: 29321262
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tracking a complete voltage-sensor cycle with metal-ion bridges.
    Henrion U; Renhorn J; Börjesson SI; Nelson EM; Schwaiger CS; Bjelkmar P; Wallner B; Lindahl E; Elinder F
    Proc Natl Acad Sci U S A; 2012 May; 109(22):8552-7. PubMed ID: 22538811
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A single charged voltage sensor is capable of gating the Shaker K+ channel.
    Gagnon DG; Bezanilla F
    J Gen Physiol; 2009 May; 133(5):467-83. PubMed ID: 19398775
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Atomic mutagenesis in ion channels with engineered stoichiometry.
    Lueck JD; Mackey AL; Infield DT; Galpin JD; Li J; Roux B; Ahern CA
    Elife; 2016 Oct; 5():. PubMed ID: 27710770
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Role of hydrophobic and ionic forces in the movement of S4 of the Shaker potassium channel.
    Elliott DJ; Neale EJ; Munsey TS; Bannister JP; Sivaprasadarao A
    Mol Membr Biol; 2012 Dec; 29(8):321-32. PubMed ID: 22881396
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.