149 related articles for article (PubMed ID: 31397037)
1. Diffusion tensor imaging of the abdominal organs: Influence of oriented intravoxel flow compartments.
Phi van V; Reiner CS; Klarhoefer M; Ciritsis A; Eberhardt C; Wurnig MC; Rossi C
NMR Biomed; 2019 Nov; 32(11):e4159. PubMed ID: 31397037
[TBL] [Abstract][Full Text] [Related]
2. Correction for fast pseudo-diffusive fluid motion contaminations in diffusion tensor imaging.
Stieb S; Klarhoefer M; Finkenstaedt T; Wurnig MC; Becker AS; Ciritsis A; Rossi C
Magn Reson Imaging; 2020 Feb; 66():50-56. PubMed ID: 31655141
[TBL] [Abstract][Full Text] [Related]
3. Combined intravoxel incoherent motion and diffusion tensor imaging of renal diffusion and flow anisotropy.
Notohamiprodjo M; Chandarana H; Mikheev A; Rusinek H; Grinstead J; Feiweier T; Raya JG; Lee VS; Sigmund EE
Magn Reson Med; 2015 Apr; 73(4):1526-32. PubMed ID: 24752998
[TBL] [Abstract][Full Text] [Related]
4. An intravoxel oriented flow model for diffusion-weighted imaging of the kidney.
Hilbert F; Bock M; Neubauer H; Veldhoen S; Wech T; Bley TA; Köstler H
NMR Biomed; 2016 Oct; 29(10):1403-13. PubMed ID: 27488570
[TBL] [Abstract][Full Text] [Related]
5. REnal Flow and Microstructure AnisotroPy (REFMAP) MRI in Normal and Peritumoral Renal Tissue.
Liu AL; Mikheev A; Rusinek H; Huang WC; Wysock JS; Babb JS; Feiweier T; Stoffel D; Chandarana H; Sigmund EE
J Magn Reson Imaging; 2018 Jul; 48(1):188-197. PubMed ID: 29331053
[TBL] [Abstract][Full Text] [Related]
6. The IVIM signal in the healthy cerebral gray matter: A play of spherical and non-spherical components.
Finkenstaedt T; Klarhoefer M; Eberhardt C; Becker AS; Andreisek G; Boss A; Rossi C
Neuroimage; 2017 May; 152():340-347. PubMed ID: 28263927
[TBL] [Abstract][Full Text] [Related]
7. Intravoxel incoherent motion analysis of abdominal organs: computation of reference parameters in a large cohort of C57Bl/6 mice and correlation to microvessel density.
Eberhardt C; Wurnig MC; Wirsching A; Rossi C; Rottmar M; Özbay PS; Filli L; Lesurtel M; Boss A
MAGMA; 2016 Oct; 29(5):751-63. PubMed ID: 27094553
[TBL] [Abstract][Full Text] [Related]
8. Integrated intravoxel incoherent motion tensor and diffusion tensor brain MRI in a single fast acquisition.
Dietrich O; Cai M; Tuladhar AM; Jacob MA; Drenthen GS; Jansen JFA; Marques JP; Topalis J; Ingrisch M; Ricke J; de Leeuw FE; Duering M; Backes WH
NMR Biomed; 2023 Jul; 36(7):e4905. PubMed ID: 36637237
[TBL] [Abstract][Full Text] [Related]
9. Optimal acquisition scheme for flow-compensated intravoxel incoherent motion diffusion-weighted imaging in the abdomen: An accurate and precise clinically feasible protocol.
Gurney-Champion OJ; Rauh SS; Harrington K; Oelfke U; Laun FB; Wetscherek A
Magn Reson Med; 2020 Mar; 83(3):1003-1015. PubMed ID: 31566262
[TBL] [Abstract][Full Text] [Related]
10. Cardiac Phase and Flow Compensation Effects on REnal Flow and Microstructure AnisotroPy MRI in Healthy Human Kidney.
Sigmund EE; Mikheev A; Brinkmann IM; Gilani N; Babb JS; Basukala D; Benkert T; Veraart J; Chandarana H
J Magn Reson Imaging; 2023 Jul; 58(1):210-220. PubMed ID: 36399101
[TBL] [Abstract][Full Text] [Related]
11. Intravoxel incoherent motion modeling in the kidneys: Comparison of mono-, bi-, and triexponential fit.
van Baalen S; Leemans A; Dik P; Lilien MR; Ten Haken B; Froeling M
J Magn Reson Imaging; 2017 Jul; 46(1):228-239. PubMed ID: 27787931
[TBL] [Abstract][Full Text] [Related]
12. Is there evidence for more than two diffusion components in abdominal organs? - A magnetic resonance imaging study in healthy volunteers.
Wurnig MC; Germann M; Boss A
NMR Biomed; 2018 Jan; 31(1):. PubMed ID: 29105178
[TBL] [Abstract][Full Text] [Related]
13. Initial experience of generalized intravoxel incoherent motion imaging and diffusion tensor imaging (GIVIM-DTI) in healthy subjects.
Ye Q; Chen Z; Zhao Y; Zhang Z; Miao H; Xiao Q; Wang M; Li J
J Magn Reson Imaging; 2016 Sep; 44(3):732-8. PubMed ID: 27079733
[TBL] [Abstract][Full Text] [Related]
14. Intravoxel incoherent motion and diffusion-tensor imaging in renal tissue under hydration and furosemide flow challenges.
Sigmund EE; Vivier PH; Sui D; Lamparello NA; Tantillo K; Mikheev A; Rusinek H; Babb JS; Storey P; Lee VS; Chandarana H
Radiology; 2012 Jun; 263(3):758-69. PubMed ID: 22523327
[TBL] [Abstract][Full Text] [Related]
15. Chronic kidney disease: Pathological and functional evaluation with intravoxel incoherent motion diffusion-weighted imaging.
Mao W; Zhou J; Zeng M; Ding Y; Qu L; Chen C; Ding X; Wang Y; Fu C
J Magn Reson Imaging; 2018 May; 47(5):1251-1259. PubMed ID: 28940646
[TBL] [Abstract][Full Text] [Related]
16. Effect of flow-encoding strength on intravoxel incoherent motion in the liver.
Moulin K; Aliotta E; Ennis DB
Magn Reson Med; 2019 Mar; 81(3):1521-1533. PubMed ID: 30276853
[TBL] [Abstract][Full Text] [Related]
17. Capability of intravoxel incoherent motion and diffusion tensor imaging to detect early kidney injury in type 2 diabetes.
Zhang H; Wang P; Shi D; Yao X; Li Y; Liu X; Sun Y; Ding J; Wang S; Wang G; Ren K
Eur Radiol; 2022 May; 32(5):2988-2997. PubMed ID: 35031840
[TBL] [Abstract][Full Text] [Related]
18. Comparison of Turbo Spin Echo and Echo Planar Imaging for intravoxel incoherent motion and diffusion tensor imaging of the kidney at 3Tesla.
Hilbert F; Wech T; Neubauer H; Veldhoen S; Bley TA; Köstler H
Z Med Phys; 2017 Sep; 27(3):193-201. PubMed ID: 28410964
[TBL] [Abstract][Full Text] [Related]
19. Intravoxel Incoherent Motion Analysis of Abdominal Organs: Application of Simultaneous Multislice Acquisition.
Phi Van VD; Becker AS; Ciritsis A; Reiner CS; Boss A
Invest Radiol; 2018 Mar; 53(3):179-185. PubMed ID: 29112516
[TBL] [Abstract][Full Text] [Related]
20. Investigation of intravoxel incoherent motion tensor imaging for the characterization of the in vivo human heart.
Zhang XS; Sang XQ; Kuai ZX; Zhang HX; Lou J; Lu Q; Zhu YM
Magn Reson Med; 2021 Mar; 85(3):1414-1426. PubMed ID: 32989786
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]