These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

236 related articles for article (PubMed ID: 31399093)

  • 21. Biomechanical comparison of intramedullary screw fixation, dorsal plating and K-wire fixation for stable metacarpal shaft fractures.
    Galbraith JG; Huntington LS; Borbas P; Ackland DC; Tham SK; Ek ET
    J Hand Surg Eur Vol; 2022 Feb; 47(2):172-178. PubMed ID: 34018870
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Single column plate plus other column lag screw fixation vs. both column plate fixation for anterior column with posterior hemitransverse acetabular fractures - a biomechanical analysis using different loading protocols.
    Le Quang H; Schmoelz W; Lindtner RA; Dammerer D; Schwendinger P; Krappinger D
    Injury; 2021 Apr; 52(4):699-704. PubMed ID: 33454060
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Double column acetabular fractures fixation using a novel dynamic anterior plate-screw system: A biomechanical analysis.
    Wu H; Song C; Shang R; Shao Q; Liu X; Zhang H; Cai X
    Injury; 2021 Mar; 52(3):407-413. PubMed ID: 33097200
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis.
    Graul I; Marintschev I; Pizanis A; Herath SC; Pohlemann T; Fritz T
    Eur J Trauma Emerg Surg; 2022 Oct; 48(5):3757-3764. PubMed ID: 34618166
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Biomechanical Comparison of Intramedullary Screw Versus Low-Profile Plate Fixation of a Jones Fracture.
    Huh J; Glisson RR; Matsumoto T; Easley ME
    Foot Ankle Int; 2016 Apr; 37(4):411-8. PubMed ID: 26637274
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures.
    Croley JS; Morris RP; Amin A; Lindsey RW; Gugala Z
    J Hand Surg Am; 2016 Jun; 41(6):703-11. PubMed ID: 27113909
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A biomechanical study of conventional acetabular internal fracture fixation versus locking plate fixation.
    Mehin R; Jones B; Zhu Q; Broekhuyse H
    Can J Surg; 2009 Jun; 52(3):221-8. PubMed ID: 19503667
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of three different fixation constructs for radial neck fractures: a biomechanical study.
    Chen H; Wu D; Pan T; Pan J; Zhang R; Shi X
    J Orthop Surg Res; 2017 Nov; 12(1):175. PubMed ID: 29137658
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Finite element analysis of the stability of transverse acetabular fractures in standing and sitting positions by different fixation options.
    Yildirim AO; Alemdaroglu KB; Yuksel HY; Öken ÖF; Ucaner A
    Injury; 2015 Jul; 46 Suppl 2():S29-35. PubMed ID: 26028425
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical comparison of fixation techniques for transverse acetabular fractures - Single-leg stance vs. sit-to-stand loading.
    Le Quang H; Schmoelz W; Lindtner RA; Schwendinger P; Blauth M; Krappinger D
    Injury; 2020 Oct; 51(10):2158-2164. PubMed ID: 32646647
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Osteosynthesis of Phalangeal Fractures: Biomechanical Comparison of Kirschner Wires, Plates, and Compression Screws.
    Rausch V; Harbrecht A; Kahmann SL; Fenten T; Jovanovic N; Hackl M; Müller LP; Staat M; Wegmann K
    J Hand Surg Am; 2020 Oct; 45(10):987.e1-987.e8. PubMed ID: 32499069
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?
    Stoffel K; Dieter U; Stachowiak G; Gächter A; Kuster MS
    Injury; 2003 Nov; 34 Suppl 2():B11-9. PubMed ID: 14580982
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Antegrade versus retrograde screw fixation of anterior column acetabular fractures: a biomechanical in vitro study.
    Osterhoff G; Wulsten D; Babu S; Heyland M; Pari C
    Eur J Trauma Emerg Surg; 2021 Oct; 47(5):1307-1312. PubMed ID: 31664465
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Locking Plate Fixation for Canine Acetabular Fractures.
    Piana F; Solano M; Kalff S; Yeadon R
    Vet Comp Orthop Traumatol; 2020 Jul; 33(4):294-300. PubMed ID: 32349136
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Finite element analysis of infra-acetabular screw fixation for the treatment of acetabular posterior column fracture.
    Wang T; Zhao B; Yan J; Shao B; Mu W
    Int Orthop; 2022 Mar; 46(3):623-634. PubMed ID: 34981159
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effect of pearl spacing on single-cycle load-to-failure and cyclic loading parameters of 2.0 mm pearl locking plates.
    Hyndman P; Worth AJ; Clark K
    N Z Vet J; 2021 Nov; 69(6):337-342. PubMed ID: 34085907
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Adjunct fixation with a Kirschner wire or a plate for lateral unicondylar humeral fracture stabilization.
    Coggeshall JD; Lewis DD; Iorgulescu A; Kim SE; Palm LS; Pozzi A
    Vet Surg; 2017 Oct; 46(7):933-941. PubMed ID: 28640455
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A biomechanical comparison of double-plate and Y-plate fixation for comminuted equine second phalangeal fractures.
    Galuppo LD; Stover SM; Willits NH
    Vet Surg; 2000; 29(2):152-62. PubMed ID: 10730708
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Biomechanical comparison of six different fixation techniques for treatment of metacarpal neck fractures].
    Gick S; Oppermann J; Owerst I; Pennig D; Dargel J
    Unfallchirurg; 2019 Aug; 122(8):587-595. PubMed ID: 31123800
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Fixation of Anteromedial Coronoid Facet Fractures: A Biomechanical Evaluation of Plated Versus Screw Constructs.
    Morellato J; Louati H; Desloges W; Papp S; Pollock JW
    J Orthop Trauma; 2018 Nov; 32(11):e451-e456. PubMed ID: 30339648
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.