These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
209 related articles for article (PubMed ID: 31399827)
1. Diagnostic accuracy of somatosensory evoked potentials during intracranial aneurysm clipping for perioperative stroke. Kashkoush AI; Nguyen C; Balzer J; Habeych M; Crammond DJ; Thirumala PD J Clin Monit Comput; 2020 Aug; 34(4):811-819. PubMed ID: 31399827 [TBL] [Abstract][Full Text] [Related]
2. Impact of changes in intraoperative somatosensory evoked potentials on stroke rates after clipping of intracranial aneurysms. Wicks RT; Pradilla G; Raza SM; Hadelsberg U; Coon AL; Huang J; Tamargo RJ Neurosurgery; 2012 May; 70(5):1114-24; discussion 1124. PubMed ID: 22067420 [TBL] [Abstract][Full Text] [Related]
3. Diagnostic Value of Somatosensory-Evoked Potential Monitoring During Cerebral Aneurysm Clipping: A Systematic Review. Thirumala PD; Udesh R; Muralidharan A; Thiagarajan K; Crammond DJ; Chang YF; Balzer JR World Neurosurg; 2016 May; 89():672-80. PubMed ID: 26709156 [TBL] [Abstract][Full Text] [Related]
4. The incidence of and risk factors for ischemic complications after microsurgical clipping of unruptured middle cerebral artery aneurysms and the efficacy of intraoperative monitoring of somatosensory evoked potentials: A retrospective study. Byoun HS; Bang JS; Oh CW; Kwon OK; Hwang G; Han JH; Kim T; Lee SU; Jo SR; Kim DG; Park KS Clin Neurol Neurosurg; 2016 Dec; 151():128-135. PubMed ID: 27838495 [TBL] [Abstract][Full Text] [Related]
5. Somatosensory Evoked Potentials During Temporary Arterial Occlusion for Intracranial Aneurysm Surgery: Predictive Value for Perioperative Stroke. Kashkoush AI; Jankowitz BT; Gardner P; Friedlander RM; Chang YF; Crammond DJ; Balzer JR; Thirumala PD World Neurosurg; 2017 Aug; 104():442-451. PubMed ID: 28526648 [TBL] [Abstract][Full Text] [Related]
8. Transcranial motor evoked potentials during basilar artery aneurysm surgery: technique application for 30 consecutive patients. Quiñones-Hinojosa A; Alam M; Lyon R; Yingling CD; Lawton MT Neurosurgery; 2004 Apr; 54(4):916-24; discussion 924. PubMed ID: 15046658 [TBL] [Abstract][Full Text] [Related]
9. Sensitivity and Specificity of Intraoperative Neuromonitoring for Identifying Safety and Duration of Temporary Aneurysm Clipping Based on Vascular Territory, a Multimodal Strategy. Staarmann B; O'Neal K; Magner M; Zuccarello M World Neurosurg; 2017 Apr; 100():522-530. PubMed ID: 28089809 [TBL] [Abstract][Full Text] [Related]
10. The Diagnostic Accuracy of Evoked Potential Monitoring Techniques During Intracranial Aneurysm Surgery for Predicting Postoperative Ischemic Damage: A Systematic Review and Meta-Analysis. Thomas B; Guo D World Neurosurg; 2017 Jul; 103():829-840.e3. PubMed ID: 28433839 [TBL] [Abstract][Full Text] [Related]
11. Effectiveness of MEP and SSEP Monitoring in the Diagnosis of Neurological Dysfunction Immediately After Craniotomy Aneurysm Clipping. Tang F; Guo P; Lan X; Shi M; Feng Y J Craniofac Surg; 2024 Jan-Feb 01; 35(1):e38-e44. PubMed ID: 37943050 [TBL] [Abstract][Full Text] [Related]
12. Intraoperative neurophysiological monitoring for intradural extramedullary spinal tumors: predictive value and relevance of D-wave amplitude on surgical outcome during a 10-year experience. Ghadirpour R; Nasi D; Iaccarino C; Romano A; Motti L; Sabadini R; Valzania F; Servadei F J Neurosurg Spine; 2019 Feb; 30(2):259-267. PubMed ID: 30497134 [TBL] [Abstract][Full Text] [Related]
13. Intraoperative evoked potential monitoring for detecting cerebral injury during adult aneurysm clipping surgery: a systematic review and meta-analysis of diagnostic test accuracy. Zhu F; Chui J; Herrick I; Martin J BMJ Open; 2019 Feb; 9(2):e022810. PubMed ID: 30760514 [TBL] [Abstract][Full Text] [Related]
14. Intraoperative use of transcranial motor/sensory evoked potential monitoring in the clipping of intracranial aneurysms: evaluation of false-positive and false-negative cases. Chung J; Park W; Hong SH; Park JC; Ahn JS; Kwun BD; Lee SA; Kim SH; Jeon JY J Neurosurg; 2019 Mar; 130(3):936-948. PubMed ID: 29570008 [TBL] [Abstract][Full Text] [Related]
15. Monitoring of motor evoked potentials compared with somatosensory evoked potentials and microvascular Doppler ultrasonography in cerebral aneurysm surgery. Neuloh G; Schramm J J Neurosurg; 2004 Mar; 100(3):389-99. PubMed ID: 15035273 [TBL] [Abstract][Full Text] [Related]
16. Analysis of motor and somatosensory evoked potentials during thoracic and thoracoabdominal aortic aneurysm repair. Keyhani K; Miller CC; Estrera AL; Wegryn T; Sheinbaum R; Safi HJ J Vasc Surg; 2009 Jan; 49(1):36-41. PubMed ID: 18829232 [TBL] [Abstract][Full Text] [Related]
18. What is the predictive value of intraoperative somatosensory evoked potential monitoring for postoperative neurological deficit in cervical spine surgery?-a meta-analysis. Reddy RP; Chang R; Rosario BP; Sudadi S; Anetakis KM; Balzer JR; Crammond DJ; Shaw JD; Thirumala PD Spine J; 2021 Apr; 21(4):555-570. PubMed ID: 33460808 [TBL] [Abstract][Full Text] [Related]
19. A prediction of postoperative neurological deficits following intracranial aneurysm surgery using somatosensory evoked potential deterioration duration. Wang M; Li Z; Fan X; Tao X; Qi L; Ling M; Guo D; Qiao H Neurosurg Rev; 2020 Feb; 43(1):293-299. PubMed ID: 30635746 [TBL] [Abstract][Full Text] [Related]