152 related articles for article (PubMed ID: 31404036)
1. Biomechanics of Periprosthetic Fixation: Plates, Nails, Cables, and Allografts.
Gausden EB; Wellman DS
J Orthop Trauma; 2019 Sep; 33 Suppl 6():S1-S4. PubMed ID: 31404036
[TBL] [Abstract][Full Text] [Related]
2. Periprosthetic femoral fracture fixation: a biomechanical comparison between proximal locking screws and cables.
Graham SM; Mak JH; Moazen M; Leonidou A; Jones AC; Wilcox RK; Tsiridis E
J Orthop Sci; 2015 Sep; 20(5):875-80. PubMed ID: 25968896
[TBL] [Abstract][Full Text] [Related]
3. High union rates of locking compression plating with cortical strut allograft for type B1 periprosthetic femoral fractures.
Yeo I; Rhyu KH; Kim SM; Park YS; Lim SJ
Int Orthop; 2016 Nov; 40(11):2365-2371. PubMed ID: 26759257
[TBL] [Abstract][Full Text] [Related]
4. Finite element analysis of different repair methods of Vancouver B1 periprosthetic fractures after total hip arthroplasty.
Chen DW; Lin CL; Hu CC; Wu JW; Lee MS
Injury; 2012 Jul; 43(7):1061-5. PubMed ID: 22336128
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system.
Hoffmann MF; Burgers TA; Mason JJ; Williams BO; Sietsema DL; Jones CB
Injury; 2014 Jul; 45(7):1035-41. PubMed ID: 24680467
[TBL] [Abstract][Full Text] [Related]
6. Better Axial Stiffness of a Bicortical Screw Construct Compared to a Cable Construct for Comminuted Vancouver B1 Proximal Femoral Fractures.
Griffiths JT; Taheri A; Day RE; Yates PJ
J Arthroplasty; 2015 Dec; 30(12):2333-7. PubMed ID: 26239233
[TBL] [Abstract][Full Text] [Related]
7. Use of Locking Plate and Strut Onlay Allografts for Periprosthetic Fracture Around Well-Fixed Femoral Components.
Kim YH; Mansukhani SA; Kim JS; Park JW
J Arthroplasty; 2017 Jan; 32(1):166-170. PubMed ID: 27407037
[TBL] [Abstract][Full Text] [Related]
8. Osteosynthesis Technique for Periprosthetic Femoral Fractures: A Case of Interprosthetic Fracture Between a Total Knee Arthroplasty and a Dynamic Hip Screw.
Page JL; Leighton RK
J Orthop Trauma; 2019 Aug; 33 Suppl 1():S28-S29. PubMed ID: 31290828
[TBL] [Abstract][Full Text] [Related]
9. [Biomechanika osteosyntézy periprotetických zlomenin femuru po aloplastice kyčelního kloubu].
SkÁla-Rosenbaum J; DŽupa V; Krbec M
Acta Chir Orthop Traumatol Cech; 2020; 87(5):309-317. PubMed ID: 33146597
[TBL] [Abstract][Full Text] [Related]
10. Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures.
Bryant GK; Morshed S; Agel J; Henley MB; Barei DP; Taitsman LA; Nork SE
Injury; 2009 Nov; 40(11):1180-6. PubMed ID: 19539924
[TBL] [Abstract][Full Text] [Related]
11. Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures.
Buttaro MA; Farfalli G; Paredes Núñez M; Comba F; Piccaluga F
J Bone Joint Surg Am; 2007 Sep; 89(9):1964-9. PubMed ID: 17768193
[TBL] [Abstract][Full Text] [Related]
12. The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both?
Shah S; Kim SY; Dubov A; Schemitsch EH; Bougherara H; Zdero R
Proc Inst Mech Eng H; 2011 Sep; 225(9):845-56. PubMed ID: 22070022
[TBL] [Abstract][Full Text] [Related]
13. Periprosthetic femoral fractures around well-fixed implants: use of cortical onlay allografts with or without a plate.
Haddad FS; Duncan CP; Berry DJ; Lewallen DG; Gross AE; Chandler HP
J Bone Joint Surg Am; 2002 Jun; 84(6):945-50. PubMed ID: 12063328
[TBL] [Abstract][Full Text] [Related]
14. Intraoperative Periprosthetic Femur Fracture: A Biomechanical Analysis of Cerclage Fixation.
Frisch NB; Charters MA; Sikora-Klak J; Banglmaier RF; Oravec DJ; Silverton CD
J Arthroplasty; 2015 Aug; 30(8):1449-57. PubMed ID: 25765131
[TBL] [Abstract][Full Text] [Related]
15. [Limited open reduction and double plates internal fixation for treatment of Vancouver type B1 periprosthetic femoral fracture after hip arthroplasty].
Zhang Y; Fan X; Liu Y; Shao J; Tang J; Liu S; Yang T; Zhang C
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Dec; 27(12):1428-31. PubMed ID: 24640358
[TBL] [Abstract][Full Text] [Related]
16. The biomechanical effect of bone quality and fracture topography on locking plate fixation in periprosthetic femoral fractures.
Leonidou A; Moazen M; Lepetsos P; Graham SM; Macheras GA; Tsiridis E
Injury; 2015 Feb; 46(2):213-7. PubMed ID: 25467710
[TBL] [Abstract][Full Text] [Related]
17. Locking plate fixation of periprosthetic femur fractures with and without cerclage wires.
Ebraheim NA; Sochacki KR; Liu X; Hirschfeld AG; Liu J
Orthop Surg; 2013 Aug; 5(3):183-7. PubMed ID: 24002835
[TBL] [Abstract][Full Text] [Related]
18. Biomechanical evaluation of periprosthetic refractures following distal femur locking plate fixation.
Alexander J; Morris RP; Kaimrajh D; Milne E; Latta L; Flink A; Lindsey RW
Injury; 2015 Dec; 46(12):2368-73. PubMed ID: 26553428
[TBL] [Abstract][Full Text] [Related]
19. Extracortical plate fixation with new plate inserts and cerclage wires for the treatment of periprosthetic hip fractures.
Bastian JD; Butscher A; Bigolin G; Zumstein MA; Nötzli HP
Int Orthop; 2014 Mar; 38(3):489-94. PubMed ID: 24091416
[TBL] [Abstract][Full Text] [Related]
20. Setting Yourself Up for Success: Locked Plating in Periprosthetic Fractures About Total Knee Arthroplasty.
Pires RE; Kfuri M
J Orthop Trauma; 2019 Sep; 33 Suppl 6():S25-S28. PubMed ID: 31404042
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]