These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 31405739)

  • 41. Transient Elastography in Acute Cellular Rejection Following Liver Transplantation: Systematic Review.
    Nacif LS; Gomes CDC; Mischiatti MN; Kim V; Paranaguá-Vezozzo D; Reinoso GL; Carrilho FJ; D'Albuquerque LC
    Transplant Proc; 2018 Apr; 50(3):772-775. PubMed ID: 29661435
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [Elastography in the diagnosis of portal hypertension in patients with liver cirrhosis].
    Lyusina EO; Pavlov CS; Ivashkin VT
    Ter Arkh; 2017; 89(2):33-37. PubMed ID: 28281513
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Liver and spleen stiffness measured by acoustic radiation force impulse elastography for noninvasive assessment of liver fibrosis and esophageal varices in patients with chronic hepatitis B.
    Ye XP; Ran HT; Cheng J; Zhu YF; Zhang DZ; Zhang P; Zheng YY
    J Ultrasound Med; 2012 Aug; 31(8):1245-53. PubMed ID: 22837289
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Can ultrasound elastography assess liver quality in brain-dead donors and predict early allograft dysfunction after transplantation?
    Huang H; Li B; Song J; Ye G; Tang X; Qu T; Yan L; Wen T; Li B; Wang W; Wu H; Xu M; Yang J; Luo Y
    Acad Radiol; 2021 Nov; 28 Suppl 1():S112-S117. PubMed ID: 34756817
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Performance of two--dimensional ultrasound shear wave elastography: reference values of normal liver stiffness in children.
    Galina P; Alexopoulou E; Zellos A; Grigoraki V; Siahanidou T; Kelekis NL; Zarifi M
    Pediatr Radiol; 2019 Jan; 49(1):91-98. PubMed ID: 30267166
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Measurement of splenic stiffness by 2D-shear wave elastography in patients with extrahepatic portal vein obstruction.
    Madhusudhan KS; Kilambi R; Shalimar ; Sahni P; Sharma R; Srivastava DN; Gupta AK
    Br J Radiol; 2018 Dec; 91(1092):20180401. PubMed ID: 30226081
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Spleen Stiffness Measurement Using 2-Dimensional Shear Wave Elastography: The Predictors of Measurability and the Normal Spleen Stiffness Value.
    Cho YS; Lim S; Kim Y; Sohn JH; Jeong JY
    J Ultrasound Med; 2019 Feb; 38(2):423-431. PubMed ID: 30039572
    [TBL] [Abstract][Full Text] [Related]  

  • 48. A new screening strategy for varices by liver and spleen stiffness measurement (LSSM) in cirrhotic patients: A randomized trial.
    Wong GLH; Kwok R; Hui AJ; Tse YK; Ho KT; Lo AOS; Lam KLY; Chan HCH; Lui RA; Au KHD; Chan HLY; Wong VWS
    Liver Int; 2018 Apr; 38(4):636-644. PubMed ID: 28853196
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Improvement of liver stiffness measurement, acoustic radiation force impulse measurements, and noninvasive fibrosis markers after direct-acting antivirals for hepatitis C virus G4 recurrence post living donor liver transplantation: Egyptian cohort.
    Alem SA; Said M; Anwar I; Abdellatif Z; Elbaz T; Eletreby R; AbouElKhair M; El-Serafy M; Mogawer S; El-Amir M; El-Shazly M; Hosny A; Yosry A
    J Med Virol; 2018 Sep; 90(9):1508-1515. PubMed ID: 29718546
    [TBL] [Abstract][Full Text] [Related]  

  • 50. The use of transient elastography and non-invasive serum markers of fibrosis in pediatric liver transplant recipients.
    Goldschmidt I; Stieghorst H; Munteanu M; Poynard T; Schlue J; Streckenbach C; Baumann U
    Pediatr Transplant; 2013 Sep; 17(6):525-34. PubMed ID: 23802661
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Prospective comparison of spleen and liver stiffness by using shear-wave and transient elastography for detection of portal hypertension in cirrhosis.
    Elkrief L; Rautou PE; Ronot M; Lambert S; Dioguardi Burgio M; Francoz C; Plessier A; Durand F; Valla D; Lebrec D; Vilgrain V; Castéra L
    Radiology; 2015 May; 275(2):589-98. PubMed ID: 25469784
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Portal venous pressure and proper graft function in living donor liver transplants in 69 patients from an Egyptian center.
    Sholkamy A; Salman A; El-Garem N; Hosny K; Abdelaziz O
    Ann Saudi Med; 2018; 38(3):181-188. PubMed ID: 29848935
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Reliability and applicability of two-dimensional shear-wave elastography for the evaluation of liver stiffness.
    Varbobitis IC; Siakavellas SI; Koutsounas IS; Karagiannakis DS; Ioannidou P; Papageorgiou MV; Pavlopoulou ID; Schizas D; Bamias G; Vlachogiannakos I; Ladas SD; Papatheodoridis GV
    Eur J Gastroenterol Hepatol; 2016 Oct; 28(10):1204-9. PubMed ID: 27340898
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Measurement of Spleen Stiffness With Acoustic Radiation Force Impulse Imaging Predicts Mortality and Hepatic Decompensation in Patients With Liver Cirrhosis.
    Takuma Y; Morimoto Y; Takabatake H; Toshikuni N; Tomokuni J; Sahara A; Matsueda K; Yamamoto H
    Clin Gastroenterol Hepatol; 2017 Nov; 15(11):1782-1790.e4. PubMed ID: 28017842
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Liver Fibrosis Staging with MR Elastography: Comparison of Diagnostic Performance between Patients with Chronic Hepatitis B and Those with Other Etiologic Causes.
    Chang W; Lee JM; Yoon JH; Han JK; Choi BI; Yoon JH; Lee KB; Lee KW; Yi NJ; Suh KS
    Radiology; 2016 Jul; 280(1):88-97. PubMed ID: 26844364
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Noninvasive prediction of portal pressure with MR elastography and DCE-MRI of the liver and spleen: Preliminary results.
    Wagner M; Hectors S; Bane O; Gordic S; Kennedy P; Besa C; Schiano TD; Thung S; Fischman A; Taouli B
    J Magn Reson Imaging; 2018 Oct; 48(4):1091-1103. PubMed ID: 29638020
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Does hepatic graft weight affect the reduction of spleen size after living donor liver transplantation?
    Chen TY; Chen CL; Huang TL; Tsang LL; Ou HY; Yu CY; Lu CH; Cheng YF
    Transplant Proc; 2010 Apr; 42(3):882-3. PubMed ID: 20430196
    [TBL] [Abstract][Full Text] [Related]  

  • 58. HIGHER VALUES IN LIVER ELASTOGRAPHY AND MELD SCORE ARE MORTALITY PREDICTORS ON LIVER TRANSPLANT WAITING LIST.
    Nacif LS; Paranagua-Vezozzo DC; Matsuda A; Alves VAF; Carrilho FJ; Farias AQ; D'Albuquerque LC; Andraus W
    Arq Bras Cir Dig; 2018 Jun; 31(1):e1360. PubMed ID: 29947694
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Transient elastography predicts fibrosis progression in patients with recurrent hepatitis C after liver transplantation.
    Rigamonti C; Donato MF; Fraquelli M; Agnelli F; Ronchi G; Casazza G; Rossi G; Colombo M
    Gut; 2008 Jun; 57(6):821-7. PubMed ID: 18218676
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Assessment of spleen stiffness using acoustic radiation force impulse imaging (ARFI): definition of examination standards and impact of breathing maneuvers.
    Karlas T; Lindner F; Tröltzsch M; Keim V
    Ultraschall Med; 2014 Feb; 35(1):38-43. PubMed ID: 24510458
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.