These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 31406022)

  • 1. Silent Aspiration of Esophageal Cooling Solution During Pulmonary Vein Isolation Using Hot Balloon.
    Chikata A; Kato T; Usuda K; Takamura M
    Circ J; 2019 Nov; 83(12):2568. PubMed ID: 31406022
    [No Abstract]   [Full Text] [Related]  

  • 2. Prevalence of esophageal ulceration after atrial fibrillation ablation with the hot balloon ablation catheter: what is the value of esophageal cooling?
    Sohara H; Satake S; Takeda H; Yamaguchi Y; Nagasu N
    J Cardiovasc Electrophysiol; 2014 Jul; 25(7):686-92. PubMed ID: 24576252
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Esophagus Sandwiched Between the Descending Aorta and Left Atrium - Pitfalls of Esophageal Cooling During Radiofrequency Hot Balloon Ablation.
    Okabe Y; Yamasaki H; Sekiguchi Y; Aonuma K; Nogami A; Ieda M
    Circ J; 2019 Sep; 83(10):2079. PubMed ID: 30918238
    [No Abstract]   [Full Text] [Related]  

  • 4. Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation.
    Deneke T; Bünz K; Bastian A; Päsler M; Anders H; Lehmann R; Meuser W; de Groot JR; Horlitz M; Haberkorn R; Mügge A; Shin DI
    J Cardiovasc Electrophysiol; 2011 Mar; 22(3):255-61. PubMed ID: 20958829
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Significance of Contact Force on Esophageal Thermal Injury During Relative High-Power Short-Duration Ablation of Atrial Fibrillation.
    Kaneshiro T; Amami K; Hijioka N; Nodera M; Yamada S; Yokokawa T; Misaka T; Hikichi T; Yoshihisa A; Takeishi Y
    Circ Arrhythm Electrophysiol; 2021 Jun; 14(6):e009897. PubMed ID: 34111947
    [No Abstract]   [Full Text] [Related]  

  • 6. The esophageal temperature probe: helpful monitoring device or inadvertent amplifier of risk?
    Musat D; Mittal S
    J Cardiovasc Electrophysiol; 2011 Mar; 22(3):262-4. PubMed ID: 20958839
    [No Abstract]   [Full Text] [Related]  

  • 7. Prevention of esophageal thermal injury during radiofrequency ablation for atrial fibrillation.
    Liu E; Shehata M; Liu T; Amorn A; Cingolani E; Kannarkat V; Chugh SS; Wang X
    J Interv Card Electrophysiol; 2012 Oct; 35(1):35-44. PubMed ID: 22717996
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sounding the warning on the potential for oesophageal injury resulting from use of the nMARQ™ for ablation of atrial fibrillation.
    Yousuf O; Calkins H
    Europace; 2015 Mar; 17(3):343-4. PubMed ID: 25573657
    [No Abstract]   [Full Text] [Related]  

  • 9. Computational method to predict esophageal temperature elevations during pulmonary vein isolation.
    Musat D; Aziz EF; Koneru J; Arshad A; Kamath GS; Mittal S; Steinberg JS
    Pacing Clin Electrophysiol; 2010 Oct; 33(10):1239-48. PubMed ID: 20546158
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Esophageal heating is not limited to left atrial ablation.
    Tsai WK; Koruth J; Reddy VY
    Circ Arrhythm Electrophysiol; 2014 Feb; 7(1):178-9. PubMed ID: 24550409
    [No Abstract]   [Full Text] [Related]  

  • 11. The challenges of preventing lethal esophageal damage during atrial fibrillation ablation continue.
    Tsuchiya T
    J Cardiovasc Electrophysiol; 2008 Nov; 19(11):1194-5. PubMed ID: 18662182
    [No Abstract]   [Full Text] [Related]  

  • 12. Luminal esophageal temperature rise and esophageal lesion formation following remote-controlled magnetic pulmonary vein isolation.
    Konstantinidou M; Wissner E; Chun JK; Koektuerk B; Metzner A; Tilz RR; Rillig A; Fuernkranz A; Wohlmuth P; Ouyang F; Kuck KH
    Heart Rhythm; 2011 Dec; 8(12):1875-80. PubMed ID: 21802392
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: results of a pilot study.
    Leite LR; Santos SN; Maia H; Henz BD; Giuseppin F; Oliverira A; Zanatta AR; Peres AK; Novakoski C; Barreto JR; Vassalo F; d'Avila A; Singh SM
    Circ Arrhythm Electrophysiol; 2011 Apr; 4(2):149-56. PubMed ID: 21325208
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Limitations of esophageal temperature-monitoring to prevent esophageal injury during atrial fibrillation ablation.
    Nakagawa H; Seres KA; Jackman WM
    Circ Arrhythm Electrophysiol; 2008 Aug; 1(3):150-2. PubMed ID: 19808408
    [No Abstract]   [Full Text] [Related]  

  • 15. Moving away from esophageal injury during left atrial ablation.
    Bunch TJ; Day JD
    Heart Rhythm; 2009 Mar; 6(3):323-4. PubMed ID: 19251205
    [No Abstract]   [Full Text] [Related]  

  • 16. Distinct Forms of Esophageal Lesions After Radiofrequency and Cryoballoon Pulmonary Vein Isolation.
    Kaneshiro T; Matsumoto Y; Hijioka N; Nodera M; Yamada S; Kamioka M; Yoshihisa A; Ohkawara H; Suzuki H; Takeishi Y
    JACC Clin Electrophysiol; 2018 Dec; 4(12):1642-1643. PubMed ID: 30573132
    [No Abstract]   [Full Text] [Related]  

  • 17. Even cooler?!
    Ernst S
    Circ Arrhythm Electrophysiol; 2013 Aug; 6(4):666-7. PubMed ID: 23962859
    [No Abstract]   [Full Text] [Related]  

  • 18. Esophageal tissue injury following pulmonary vein isolation using the PVAC: assessment by endoscopy and magnetic resonance imaging.
    von Bary C; Dornia C; Kirchner G; Weber S; Fellner C; Nisenbaum D; Georgieva M; Stroszczynski C; Hamer OW
    Pacing Clin Electrophysiol; 2013 Apr; 36(4):477-85. PubMed ID: 23379955
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Increased incidence of esophageal thermal lesions using the second-generation 28-mm cryoballoon.
    Metzner A; Burchard A; Wohlmuth P; Rausch P; Bardyszewski A; Gienapp C; Tilz RR; Rillig A; Mathew S; Deiss S; Makimoto H; Ouyang F; Kuck KH; Wissner E
    Circ Arrhythm Electrophysiol; 2013 Aug; 6(4):769-75. PubMed ID: 23748208
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Esophagus-Related Complications During Second-Generation Cryoballoon Ablation-Insight from Simultaneous Esophageal Temperature Monitoring from 2 Esophageal Probes.
    Miyazaki S; Nakamura H; Taniguchi H; Takagi T; Iwasawa J; Watanabe T; Hachiya H; Hirao K; Iesaka Y
    J Cardiovasc Electrophysiol; 2016 Sep; 27(9):1038-44. PubMed ID: 27221011
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.