These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 31409125)

  • 1. Artificial Pancreas Systems and Physical Activity in Patients with Type 1 Diabetes: Challenges, Adopted Approaches, and Future Perspectives.
    Tagougui S; Taleb N; Molvau J; Nguyen É; Raffray M; Rabasa-Lhoret R
    J Diabetes Sci Technol; 2019 Nov; 13(6):1077-1090. PubMed ID: 31409125
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In Silico Analysis of an Exercise-Safe Artificial Pancreas With Multistage Model Predictive Control and Insulin Safety System.
    Garcia-Tirado J; Colmegna P; Corbett JP; Ozaslan B; Breton MD
    J Diabetes Sci Technol; 2019 Nov; 13(6):1054-1064. PubMed ID: 31679400
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Adaptive Control of an Artificial Pancreas Using Model Identification, Adaptive Postprandial Insulin Delivery, and Heart Rate and Accelerometry as Control Inputs.
    Resalat N; Hilts W; Youssef JE; Tyler N; Castle JR; Jacobs PG
    J Diabetes Sci Technol; 2019 Nov; 13(6):1044-1053. PubMed ID: 31595784
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Bio-inspired Artificial Pancreas for Type 1 Diabetes Control in the Home: System Architecture and Preliminary Results.
    Herrero P; El-Sharkawy M; Daniels J; Jugnee N; Uduku CN; Reddy M; Oliver N; Georgiou P
    J Diabetes Sci Technol; 2019 Nov; 13(6):1017-1025. PubMed ID: 31608656
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Single- and Dual-Hormone Artificial Pancreas for Overnight Glucose Control in Type 1 Diabetes.
    Haidar A; Rabasa-Lhoret R; Legault L; Lovblom LE; Rakheja R; Messier V; D'Aoust É; Falappa CM; Justice T; Orszag A; Tschirhart H; Dallaire M; Ladouceur M; Perkins BA
    J Clin Endocrinol Metab; 2016 Jan; 101(1):214-23. PubMed ID: 26523526
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automated blood glucose control in type 1 diabetes: A review of progress and challenges.
    Bertachi A; Ramkissoon CM; Bondia J; Vehí J
    Endocrinol Diabetes Nutr (Engl Ed); 2018 Mar; 65(3):172-181. PubMed ID: 29279252
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An artificial pancreas for automated blood glucose control in patients with Type 1 diabetes.
    Schmidt S; Boiroux D; Ranjan A; Jørgensen JB; Madsen H; Nørgaard K
    Ther Deliv; 2015; 6(5):609-19. PubMed ID: 26001176
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Do-It-Yourself Artificial Pancreas Systems: A Review of the Emerging Evidence and Insights for Healthcare Professionals.
    Jennings P; Hussain S
    J Diabetes Sci Technol; 2020 Sep; 14(5):868-877. PubMed ID: 31847570
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Classification of Physical Activity: Information to Artificial Pancreas Control Systems in Real Time.
    Turksoy K; Paulino TM; Zaharieva DP; Yavelberg L; Jamnik V; Riddell MC; Cinar A
    J Diabetes Sci Technol; 2015 Oct; 9(6):1200-7. PubMed ID: 26443291
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Who needs an artificial pancreas? (?).
    Winikoff J; Drexler A
    J Diabetes; 2013 Sep; 5(3):254-7. PubMed ID: 23601378
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Advances in Closed-Loop Insulin Delivery Systems in Patients with Type 1 Diabetes.
    Dadlani V; Pinsker JE; Dassau E; Kudva YC
    Curr Diab Rep; 2018 Aug; 18(10):88. PubMed ID: 30159816
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The International Diabetes Closed-Loop Study: Testing Artificial Pancreas Component Interoperability.
    Anderson SM; Dassau E; Raghinaru D; Lum J; Brown SA; Pinsker JE; Church MM; Levy C; Lam D; Kudva YC; Buckingham B; Forlenza GP; Wadwa RP; Laffel L; Doyle FJ; DeVries JH; Renard E; Cobelli C; Boscari F; Del Favero S; Kovatchev BP
    Diabetes Technol Ther; 2019 Feb; 21(2):73-80. PubMed ID: 30649925
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of an Artificial Pancreas with Enhanced Model Predictive Control and a Glucose Prediction Trust Index with Unannounced Exercise.
    Pinsker JE; Laguna Sanz AJ; Lee JB; Church MM; Andre C; Lindsey LE; Doyle FJ; Dassau E
    Diabetes Technol Ther; 2018 Jul; 20(7):455-464. PubMed ID: 29958023
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multivariable Artificial Pancreas for Various Exercise Types and Intensities.
    Turksoy K; Hajizadeh I; Hobbs N; Kilkus J; Littlejohn E; Samadi S; Feng J; Sevil M; Lazaro C; Ritthaler J; Hibner B; Devine N; Quinn L; Cinar A
    Diabetes Technol Ther; 2018 Oct; 20(10):662-671. PubMed ID: 30188192
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Randomized trial of a dual-hormone artificial pancreas with dosing adjustment during exercise compared with no adjustment and sensor-augmented pump therapy.
    Jacobs PG; El Youssef J; Reddy R; Resalat N; Branigan D; Condon J; Preiser N; Ramsey K; Jones M; Edwards C; Kuehl K; Leitschuh J; Rajhbeharrysingh U; Castle JR
    Diabetes Obes Metab; 2016 Nov; 18(11):1110-1119. PubMed ID: 27333970
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.
    Hanazaki K; Munekage M; Kitagawa H; Yatabe T; Munekage E; Shiga M; Maeda H; Namikawa T
    J Artif Organs; 2016 Sep; 19(3):209-18. PubMed ID: 27142278
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Controlling the AP Controller: Controller Performance Assessment and Modification.
    Hajizadeh I; Hobbs N; Samadi S; Sevil M; Rashid M; Brandt R; Askari MR; Maloney Z; Cinar A
    J Diabetes Sci Technol; 2019 Nov; 13(6):1091-1104. PubMed ID: 31561714
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Emerging Technologies for Diabetes Care.
    Bailey TS; Walsh J; Stone JY
    Diabetes Technol Ther; 2018 Jun; 20(S2):S278-S284. PubMed ID: 29916738
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Effects of Basal Insulin Suspension at the Start of Exercise on Blood Glucose Levels During Continuous Versus Circuit-Based Exercise in Individuals with Type 1 Diabetes on Continuous Subcutaneous Insulin Infusion.
    Zaharieva D; Yavelberg L; Jamnik V; Cinar A; Turksoy K; Riddell MC
    Diabetes Technol Ther; 2017 Jun; 19(6):370-378. PubMed ID: 28613947
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stress Testing of an Artificial Pancreas System With Pizza and Exercise Leads to Improvements in the System's Fuzzy Logic Controller.
    Mauseth R; Lord SM; Hirsch IB; Kircher RC; Matheson DP; Greenbaum CJ
    J Diabetes Sci Technol; 2015 Sep; 9(6):1253-9. PubMed ID: 26370244
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.